Contactor K 44 For 60 Kva Transformer Rated Current 95 Amp, Rated Voltage690 V Ac, Main Pole 4, Auxillary Contact 1 No 1 Nc, Control Voltage 230 Volt Ac (168 V Ac300 V Ac) With Surge Suppressor. Place Of Location In Sbc : S1 K44 Conf Make : Abb, Schneider, Siemens & L&T Only
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106581623
Reference
Number
92255083
Tender Fee 0
EMD 0
Tender Value -
Place Mumbai CST
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/022025/106584988/viewNitPdf_4844677.pdf

Start Date January 24, 2025 16:54
End Date
Expired 10/02/2025

Expired 612 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Contactor 170 amps 4 pole with auxillary contacts 1 no +1 nc coil voltage 415 v ac as per abb type ek -110-40-11+cal 16. 11b accepted brand abb /schneider / siemens only.

Contactor 170 amps 4 pole with auxillary contacts 1 no +1 nc coil voltage 415 v ac as per abb type ek -110-40-11+cal 16. 11b accepted brand abb /schneider / siemens only.

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Read more
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Read more
Kva ,750 v ac onload switching under ac-6a category at temperature of 70 degree centigrade & coil voltage of 110 v+ 25 percent -30 percent dc with surge suppressor ,2 no+2 nc for lslrd coaches as per rdso specification no .rdso/pe/spec/tl/0195-2019 (rev.-0)or latest. accepted makes as per above spec.: abb modelno.af1250-30-11, l&t model no. mvo 820, siemens model no3tf69338 df4z a02+3tx75723h only.

Kva ,750 v ac onload switching under ac-6a category at temperature of 70 degree centigrade & coil voltage of 110 v+ 25 percent -30 percent dc with surge suppressor ,2 no+2 nc for lslrd coaches as per rdso specification no .rdso/pe/spec/tl/0195-2019 (rev.-0)or latest. accepted makes as per above spec.: abb modelno.af1250-30-11, l&t model no. mvo 820, siemens model no3tf69338 df4z a02+3tx75723h only.

Read more
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Read more
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de

Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de