Tender Details

Particulars Details
Title
Power Contactor [With Diode] For Compressor Unit Of Lhb Type Ac Coaches, 3 Pole, Rated Current 32 A (At Rated Voltage & Ac 3 Utilization Category), Rated Voltage 690 V, Coil Voltage 77 143 Vdc, With Surge Supressor, With 1 Nc Aux Contact, Conforming To Rdso Spec No. Rdso / Pe / Spec / Ac / 0184 2015 (Rev1), Suitable For Lhb Type Ac Coaches Switch Board Cabinet [Place Of Intallation S1 K33, S1 K34, S1 K38, S1 K39]. Accepted Make & Cat Nos.: As Per Sr. No. 60 Of Common Bom Of Rdso Letter No. E
Description
Power Contactor [With Diode] For Compressor Unit Of Lhb Type Ac Coaches, 3 Pole, Rated Current 32 A (At Rated Voltage & Ac 3 Utilization Category), Rated Voltage 690 V, Coil Voltage 77 143 Vdc, With Surge Supressor, With 1 Nc Aux Contact, Conforming To Rdso Spec No. Rdso / Pe / Spec / Ac / 0184 2015 (Rev1), Suitable For Lhb Type Ac Coaches Switch Board Cabinet [Place Of Intallation S1 K33, S1 K34, S1 K38, S1 K39]. Accepted Make & Cat Nos.: As Per Sr. No. 60 Of Common Bom Of Rdso Letter No. E
Organisation Ministry of Railways
Tender Id Login to view
Reference
Number
Login to view
Tender Fee -
EMD -
Tender Value -
Place
Link Login to view
Start Date September 17, 2026 18:16
End Date
Open 22/10/2026

5 days left

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)

3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)

Read more
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)

Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Knuckle as per sanrok drg no 1ed -1067 for lhb coaches h type centre buffer coupler rdso spec no. rdso/2011/cg-03 rev. 01

Knuckle as per sanrok drg no 1ed -1067 for lhb coaches h type centre buffer coupler rdso spec no. rdso/2011/cg-03 rev. 01

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Read more
Adaptor assembly for jumper plug of 500 amp. iv coupler for lhb ac coaches conforming to rdso specification rdso/pe/spec/ac/0177 (rev.2) - 2013.

Adaptor assembly for jumper plug of 500 amp. iv coupler for lhb ac coaches conforming to rdso specification rdso/pe/spec/ac/0177 (rev.2) - 2013.

Read more
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole: 4 nos., aux contact: 2no + 2nc, control voltage-380-415v ac with surge suppressor for net-1 & net -2 in sbcof lhb ac coaches confirming to item no. 57 & 58 of bom of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0). [ warranty period: 30 months after the date of delivery ]

Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole: 4 nos., aux contact: 2no + 2nc, control voltage-380-415v ac with surge suppressor for net-1 & net -2 in sbcof lhb ac coaches confirming to item no. 57 & 58 of bom of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0). [ warranty period: 30 months after the date of delivery ]

Read more
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Read more
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Read more
Wing handle with key of material stainless steel equivalent to dirak part no. 352 2199.04 - 00000 suitable for switchboard cabinet of lhb ac coaches confirming to rdso spec rdso/pe/spec/ac/0184-2015 (rev.1). material is dirak part no. 352 - 2199.04 - 00000 or equivalent part of south co. or arihant or darshana.

Wing handle with key of material stainless steel equivalent to dirak part no. 352 2199.04 - 00000 suitable for switchboard cabinet of lhb ac coaches confirming to rdso spec rdso/pe/spec/ac/0184-2015 (rev.1). material is dirak part no. 352 - 2199.04 - 00000 or equivalent part of south co. or arihant or darshana.

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise