Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Contactor 3 Pole, 32 Amp. Capacity Suitable For 690 V, 50 Hz Ac, Coil Voltage 77 143 V Dc With Auxiliary Contact 1 Nc With Surge Suppressor As Per Rdso Common Bill Of Material Vide Rdso Letter No. El/7.1.108/Mssbc Dt. 17/09/21
|
| Description |
Contactor 3 Pole, 32 Amp. Capacity Suitable For 690 V, 50 Hz Ac, Coil Voltage 77 143 V Dc With Auxiliary Contact 1 Nc With Surge Suppressor As Per Rdso Common Bill Of Material Vide Rdso Letter No. El/7.1.108/Mssbc Dt. 17/09/21
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 10, 2026 19:28 |
| End Date |
Open
23/10/2026
8 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreBracket fan 225 mm sweep, 110 v ac conforming to rdso specification no. is:6680-92 with annexure h (december2005) for rc fan issued by rdso vide lr. no. qe/6.5.1 dated 10.03.2006. the fan base, motor body and bracket shall conform to icf drg.no. icf/sk-7-6-179 with elegant, compact, lightweight aluminium body, anti-corrosive and frp blade. the fan shall have ball bearings at both the ends with skf/nbf ball bearing. the guard shall be crashworthy design to drg.no. icf/sk 7-6-158 col.ii alt. g.
Bracket fan 225 mm sweep, 110 v ac conforming to rdso specification no. is:6680-92 with annexure h (december2005) for rc fan issued by rdso vide lr. no. qe/6.5.1 dated 10.03.2006. the fan base, motor body and bracket shall conform to icf drg.no. icf/sk-7-6-179 with elegant, compact, lightweight aluminium body, anti-corrosive and frp blade. the fan shall have ball bearings at both the ends with skf/nbf ball bearing. the guard shall be crashworthy design to drg.no. icf/sk 7-6-158 col.ii alt. g.
Read moreSealed maintenance free valve regulated lead acid rechargeable battery of normal voltage 12 v, nominal capacity of 7 ah suitable for use of emergency light unit of lhb type ac coaches (test certificate to be enclosed along with batteries). the battery shall not be more than 2 months old from the date of manufacture, at the time of supply. acceptable makes as per bill of material rdso/pe/spec/ac/0180-2016 (rev-0)/latest: m/s. exide, m/s. tafe (amco), m/s. amar raja, m/s. hbl note: item to be p
Sealed maintenance free valve regulated lead acid rechargeable battery of normal voltage 12 v, nominal capacity of 7 ah suitable for use of emergency light unit of lhb type ac coaches (test certificate to be enclosed along with batteries). the battery shall not be more than 2 months old from the date of manufacture, at the time of supply. acceptable makes as per bill of material rdso/pe/spec/ac/0180-2016 (rev-0)/latest: m/s. exide, m/s. tafe (amco), m/s. amar raja, m/s. hbl note: item to be p
Read moreMpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Mpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Read morePercent ufeffcontactor k-44 for 60 kva transformer rated current -95amp, rated voltage- 690 v ac, main pole - 4, auxillary contact 1 no 1 nc, control voltage - 230 volt ac (168 v ac-300 v ac) with surge suppressor.place of location in sbc : s1k44conf to rdso bom letterno.el/7.1.108/mssbc dt.-17-09-2021 & rdso letter no. el/7.1.108/mssbc dt.- 24-06-2021. make-rdso approve make only.
For complete deion and other details, please refer to tender
Read morePercent ufeffcontactor k-44 for 60 kva transformer rated current -95amp, rated voltage- 690 v ac, main pole - 4, auxillary contact 1 no 1 nc, control voltage - 230 volt ac (168 v ac-300 v ac) with surge suppressor.place of location in sbc : s1k44conf to rdso bom letterno.el/7.1.108/mssbc dt.-17-09-2021 & rdso letter no. el/7.1.108/mssbc dt.- 24-06-2021. make-rdso approve make only.
For complete deion and other details, please refer to tender
Read morePercent ufeffcontactor k-44 for 60 kva transformer rated current -95amp, rated voltage- 690 v ac, main pole - 4, auxillary contact 1 no 1 nc, control voltage - 230 volt ac (168 v ac-300 v ac) with surge suppressor.place of location in sbc : s1k44conf to rdso bom letterno.el/7.1.108/mssbc dt.-17-09-2021 & rdso letter no. el/7.1.108/mssbc dt.- 24-06-2021. make-rdso approve make only.
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer current rating 95 amp. rated voltage: 690 v ac, main pole: 4, aux. contact: 1no1nc, control voltage: 168-300v ac means 230 v ac /- 30 percent with surge suppressor, make: abb/ sneider/ siemens/ l & t only and as per rdso letter no. el/7.1.108/mssbc dated-17.09.2021 for common bill of material of switch board cabinet,
For complete deion and other details, please refer to tender
Read moreAuxiliary contactor, for controller ok contacts: 3 no 1 nc control voltage: 77- 143 v dc with surge suppressor
For complete deion and other details, please refer to tender
Read moreof your Industry type