| Particulars | Details |
|---|---|
| Title |
Residual Current Circuit Breaker With Overload (Rcbo) 16 A, 4 Pole With Type D Tripping Curves. 415 V,50 Hz, Sensibility 30m A Ac. Breaking Capacity 6 10 Ka, Suitable To Fit With Din Rail Clamps. Impulse Current Withstands At 8/20 Microseconds Pulses = 3k A, Make: Legrand (Or) Schneider (Or) Abb (Or) Lk (Or) Siemens Only. Similar To Cat No. Auf3 D401603, Part No : A9 N4 P16 D, A9 V61440. The Material Shall Be Procured From The Said Oem Or Their Authorized Dealers With Tender Specific Authorization Onl
|
| Description |
Residual Current Circuit Breaker With Overload (Rcbo) 16 A, 4 Pole With Type D Tripping Curves. 415 V,50 Hz, Sensibility 30m A Ac. Breaking Capacity 6 10 Ka, Suitable To Fit With Din Rail Clamps. Impulse Current Withstands At 8/20 Microseconds Pulses = 3k A, Make: Legrand (Or) Schneider (Or) Abb (Or) Lk (Or) Siemens Only. Similar To Cat No. Auf3 D401603, Part No : A9 N4 P16 D, A9 V61440. The Material Shall Be Procured From The Said Oem Or Their Authorized Dealers With Tender Specific Authorization Onl
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 08, 2026 16:24 |
| End Date |
Closing soon
15/10/2026
0 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Rcbo (residual current circuit breaker with over current protection) , 4 pole, 16 amps, 415 v ac, sensitivity 30ma, breaking capacity 10 ka, din rail mounted to rcf spec: edts 355 rev-01 (item no.5 of rcf drg no.cc72082) to legrand model no: 411365 (old model no.603395) or similar. acceptable makes: l&t, schneiner, legrand, siemens, abb, havells, eaton, bussmann.
For complete deion and other details, please refer to tender
Read more4 pole rcbo 16a, 240/415v ac, with a sensitivity of 30ma, as per cat. no. 6033-95 of m/s legrand, or equivalent, confirming to rcf drg. no. cc72082 alteration-c and rcf specification no. edts-355 rev-1 with amendments no. 1 to 6, suitable for use in a set of panels for lhb non-ac coaches. accepted make: legrand or any other make with prior approval from rdso.
For complete deion and other details, please refer to tender
Read more4 pole rcbo 16a, 240/415v ac, with a sensitivity of 30ma, as per cat. no. 6033-95 of m/s legrand, or equivalent, confirming to rcf drg. no. cc72082 alteration-c and rcf specification no. edts-355 rev-1 with amendments no. 1 to 6, suitable for use in a set of panels for lhb non-ac coaches. accepted make: legrand or any other make with prior approval from rdso.
For complete deion and other details, please refer to tender
Read moreRcbo 4 pole (3pn), 16 amps, 415 v ac, sensitivity 30ma, breaking capacity 10ka, din rail mounted for lhb non ac coaches, conforming to edts-355(rev. 1) or latest, iec 61009-1, is 12640-2, en 61009-1 with isi mark. makes - siemens, legrand, mds or any rdso approved vender with latest amendment.
For complete deion and other details, please refer to tender
Read moreResidual circuit breaker with overload (rcbo), 4 pole, 16 amp, 415 volt ac, sensitivity 30ma, breaking capacity 10ka, din rail mounted to cat no. 6033-95 of legrand or similar confirming to item no.5 of fuse and terminal panel to edts-355 rev-0 amend.-4 , for lhb eog non ac coaches drg no.- cc72082
For complete deion and other details, please refer to tender
Read moreResidual current circuit breaker (rccb) for earth leakage protection double pole, 230v, 50hz,rating :25 amps,sensitivity-30ma, confirming to is 12640(part-i)/iec-61008-1, similar to f362 of abb make, legrand make cat no. 411851 , l&t make cat bg 202503, schneider make cat. no. a9n19667. accepted make : abb, schneider , legarnd and l&t or similar
For complete deion and other details, please refer to tender
Read moreof your Industry type