Tender Details
Particulars | Details |
---|---|
Title |
Rcbo 4 Pole (3 Pn), 16 Amps, 415 V Ac, Sensitivity 30 Ma, Breaking Capacity 10 Ka, Din Rail Mounted For Lhb Non Ac Coaches, Conforming To Edts 355(rev. 1) Or Latest, Iec 61009 1, Is 12640 2, En 61009 1 With Isi Mark. Makes Siemens, Legrand, Mds Or Any Rdso Approved Vender With Latest Amendment.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106240512 |
Reference Number |
AP235465 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Guwahati |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/012024/106240512/viewNitPdf_4450201.pdf |
Start Date | January 10, 2024 14:17 |
End Date |
18/01/2024 ( Expired 460 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Power contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender
Read more4 pole rcbo 16a, 240/415v ac, with a sensitivity of 30ma, as per cat. no. 6033-95 of m/s legrand, or equivalent, confirming to rcf drg. no. cc72082 alteration-c and rcf specification no. edts-355 rev-1 with amendments no. 1 to 6, suitable for use in a set of panels for lhb non-ac coaches. accepted make: legrand or any other make with prior approval from rdso.
For complete deion and other details, please refer to tender
Read moreHrc fuse link 6 amps capacity, 2 hole fixing bolted, 415v ac, having rupturing capacity 80 ka, a2, 3nw tia of siemens/gs/ge/abb make confirming to is: 13703-part-ii or latest as per rcf drawing no. cc72082 of edts 355. accepted make siemens,gs,ge & abb.
For complete deion and other details, please refer to tender
Read moreSupply of high voltage fuse link rating - 25 amps, volt - 1000 vac breaking capacity - 120ka for use in lhb non ac - coaches as per spec no edts 355 rev -1 or latest
For complete deion and other details, please refer to tender
Read moreSupply of high voltage fuse 20 amps, cyl [supply of high voltage fuse 20 amps, cylindrical type with striker in 20,breaking capacity 3.6kv/40ka to eaton bussman make model no. k3pgx20, makes:- make: siemens, wohner, ital weber, ferraz, bussmann (eaton), schneider, ge, l&t only suitable for non ac lhb coaches. note :- (1) the firm should submit authorized dealership certificate or proof of purchase from oem or dealer and necessary test certificates (2)firm should mention make and model no. whil
For complete deion and other details, please refer to tender
Read moreMcb for heater unit with auxillary contact block having ratings: 3 pole, 415v ac, rated current 16 amps, c-curve, breaking capacity 10ka as per sn-36 of bom for switch board cabinet unit having rdso s specification no. rdso/pe/spec/0184-2015(rev-1). make: abb/schneider/l&t/siemens/eaton. note: oem or their authorized dealers with tender specific authorization letters from oem only to quote with documentary evidence
For complete deion and other details, please refer to tender
Read more63a mcb, 2 pole, 415v, breaking capacity 10ka, isi marked as per is/ iec 60898-1 2002, 50 hz, c curve used as electric burner 4 at lhb ac pantry car confirming to rcf specification edts 134, rev d, am-2. material make is mds-legrand or moeller as per bom of the said specification. material procures from said oem or his authorized dealers with tender specific authorization only.
For complete deion and other details, please refer to tender
Read moreHrc fuse 25amps, 25 ka breaking capacity [hrc fuse 25amps, 25 ka breaking capacity,1000 v ac din type suitable for use in tl lhb coaches panel as per is:13703/iec 269-2 & confirming to rcf specification no. edts-355 rev.-1 or latest, suitable for use in switch board cabinet panel of non ac lhb eog coaches as per sr.no. 1 of bill of material of rcf specification no. edts-355 rev.-1. make : siba,ge,ferraz,simens,bussman,l&t,schneider,efen,eti,dimension for mechanical design as per is:13703, a1=7
For complete deion and other details, please refer to tender
Read moreHrc fuse link 16 amp , offtag bolted [hrc fuse link 16 amp , offtag bolted type , rated voltage : 500 v , breaking capacity : 80 ka , class : gg , size : a2 suitable for tl coaches similar to the part no : 3nwtia16 of m/s siemens conforming to is : 13703 pt2/sec2 , iec 60269-2 or latest , makes: siemens, wohner, ital weber, ferraz, bussmann, schneider, ge, l&t only suitable for non ac lhb coaches.]
For complete deion and other details, please refer to tender
Read moreDouble inlet centrifugal blower assembly complete with mounting brackets suitable for exhaust fan in lhb type coaches, type - double inlet centrifugal blower speed: 1500 rpm, air volume: 625 cmh, power input: 200 w, current: 0.4 amps, voltage: 415 v 3 phase ac, frequency: 50 hz, conforming to rcf specification no. edts 331, amendment-1, type -1, corr.1,2 & 3 or latest.
For complete deion and other details, please refer to tender
Read moreof your Industry type