Tender Details
Particulars | Details |
---|---|
Title |
25 A 2 P Ac Rcb Os ( Residual Current Breaker With Over Current Protection ) Conforms To Iec 61009 1, Is 12640 2, En 61009 1, Short Circuit Breaking Capacity 10 Ka, Precise Sensitivity: 300m A, Module : 2, With Cat No. Auf3 C202530 Suitable For Isolation. Make: L&T (Or) Havells (Or) Legrand (Or) Hager (Or) Abb And Manex
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106558782 |
Reference Number |
14245415 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Gorakhpur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106558782/viewNitPdf_4811244.pdf |
Start Date | December 19, 2024 22:11 |
End Date |
26/12/2024 ( Expired 136 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
63a mcb, 2 pole, 415v, breaking capacity 10ka, isi marked as per is/ iec 60898-1 2002, 50 hz, c curve used as electric burner 4 at lhb ac pantry car confirming to rcf specification edts 134, rev d, am-2. material make is mds-legrand or moeller as per bom of the said specification. material procures from said oem or his authorized dealers with tender specific authorization only.
For complete deion and other details, please refer to tender
Read moreMcb for pump controller. voltage rating [mcb for pump controller. voltage rating 200v dc, 2 pole, current rating 6a, breaking capacity 10ka similar to cat no. 5sy5206-7cc of m/s. siemens. accepted make as per bom of rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) brands: l&t/siemens/schneider/abb/eaton only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance. 2) the firm should ment
For complete deion and other details, please refer to tender
Read more25a 2p ac rcbos ( residual current breaker with over current protection ) conforms to iec 61009 -1, is 12640 -2, en 61009-1, short circuit breaking capacity - 10ka, precise sensitivity: 300ma, module : 2, with cat no. auf3c202530 suitable for isolation. make: l&t (or) havells (or) legrand (or) hager (or) abb and manex
For complete deion and other details, please refer to tender
Read moreEarth leakage circuit breaker (elcb) current rating 25 amps , 2 pole , rated sensitivity 30 ma , ip 20, voltage rating 230 volt ac as per specification edts-118 rev. e am 2 corr. 2. material make shall be siemens or legrand or l&t or abb or schneider. material shall be procured from oem or his authorized dealers with tender specific authorization only.
For complete deion and other details, please refer to tender
Read moreMcb for pump controller. voltage rating [mcb for pump controller. voltage rating 200v dc, 2 pole, current rating 6a, breaking capacity 10ka similar to cat no. 5sy5206-7cc of m/s. siemens. accepted make as per bom of rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) brands: l&t/siemens/schneider/abb/eaton only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance. 2) the firm should ment
For complete deion and other details, please refer to tender
Read more63 amps miniature circuit breaker (mcb), [63 amps miniature circuit breaker (mcb), triple pole, type c63, breaking/short circuit capacity: 10000a, 240/415v ac, 50 hz supply, rated current: 63 amps, conforms to is/iec: 60898-1. make: cona or c&s electric or havells or l&t or anchor or bch or schneider or abb or indoasian.]
For complete deion and other details, please refer to tender
Read more32 amps miniature circuit breaker (mcb), [32 amps miniature circuit breaker (mcb), triple pole, type c32, breaking/short circuit capacity: 10000a, 240/415v ac, 50 hz supply, rated current: 32 amps, conforms to is/iec: 60898-1. make: cona or c&s electric or havells or l&t or anchor or bch or schneider or abb or indoasian.]
For complete deion and other details, please refer to tender
Read moreResidual circuit breaker with overload (rcbo), 4 pole, 16 amps, 415v ac, with sensitivity: 30 ma, breaking capacity: 10ka, din rail mounting type, as per drg. no. cc72082, item no. 5, edts-355 rev-01. preferable make - legrand, l&t, schneider, siemens, abb, havells, eaton bussmann, mds.
For complete deion and other details, please refer to tender
Read moreRcbo 4 pole (3pn), 16 amps, 415 v ac, sensitivity 30ma, breaking capacity 10ka, din rail mounted for lhb non ac coaches, conforming to edts-355(rev. 1) or latest, iec 61009-1, is 12640-2, en 61009-1 with isi mark.
For complete deion and other details, please refer to tender
Read moreMiniature circuit breaker , tree pole with neutral , 63 amps, c-curve, 10ka, isi marked as per is/iec 60898-1-2002 similar to cat. no. 408683 of legrand make. make: legrand/siemens/abb/schneider. miniature circuit breaker , tree pole with neutral , 32 amps, c-curve, 10ka, isi marked as per is/iec 60898-1-2002 similar to cat. no. 408680 of legrand make. make: legrand/siemens/abb/schneider.
For complete deion and other details, please refer to tender
Read moreof your Industry type