Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Rcbo (Residual Current Circuit Breaker With Over Current Protection) , 4 Pole, 16 Amps, 415 V Ac, Sensitivity 30m A, Breaking Capacity 10 Ka, Din Rail Mounted To Rcf Spec: Edts 355 Rev 01 (Item No.5 Of Rcf Drg No.Cc72082) To Legrand Model No: 411365 (Old Model No.603395) Or Similar. Acceptable Makes: L&T, Schneiner, Legrand, Siemens, Abb, Havells, Eaton, Bussmann.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106805326 |
|
Reference Number |
42251178A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Hubli |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092025/106805326/viewNitPdf_5089153.pdf |
| Start Date | August 23, 2025 03:17 |
| End Date |
Expired
22/09/2025
Expired 389 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Miniature circuit breaker 02 ampere 2 pole 10 ka as per legrand model no. c2 curve dx3 for 3 phase ac locomotives. make-abb, schneider, legrand, eaton, siemens.
Miniature circuit breaker 02 ampere 2 pole 10 ka as per legrand model no. c2 curve dx3 for 3 phase ac locomotives. make-abb, schneider, legrand, eaton, siemens.
Read moreDin type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Read moreMpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Mpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Read more4 pole rcbo 16a,240/415v ac, with sensitivity 30ma
For complete deion and other details, please refer to tender
Read moreFour pole rcbo 16amps, 240/415 ac with sensitivity 30ma, din rail
For complete deion and other details, please refer to tender
Read moreProcurement of rcbo 4 pole, 16 amp., 415v ac, with sensitivity 30ma, b etc.
For complete deion and other details, please refer to tender
Read moreRccb (residual current circuit breaker) 25amps, 2 pole & sensitivity 30ma, din rail mounting type
For complete deion and other details, please refer to tender
Read moreResidual circuit breaker with overload (rcbo), 4 pole, 16 amps, 415v ac, with sensitivity: 30 ma, breaking capacity: 10ka, din rail mounting type, as per drg. no. cc72082, item no. 5, edts-355 rev-01. preferable make - legrand, l&t, schneider, siemens, abb, havells, eaton bussmann, mds.
For complete deion and other details, please refer to tender
Read moreResidual current circuit breaker with over current protection make legrand model no 411395,residual
Read more
4 pole rcbo 16a, 240/415v ac, with a sensitivity of 30ma, as per cat. no. 6033-95 of m/s legrand, or equivalent, confirming to rcf drg. no. cc72082 alteration-c and rcf specification no. edts-355 rev-1 with amendments no. 1 to 6, suitable for use in a set of panels for lhb non-ac coaches. accepted make: legrand or any other make with prior approval from rdso.
For complete deion and other details, please refer to tender
Read moreof your Industry type