Ttps Mech Ii Tm Ii Unit Iv Inspection And Rectification Of Epoxy Cladding Over The Condenser East West Front Side Tube Sheet And Water Box In The Reduced Thickness Area Rebuild The Claddings With Special Epoxy Putties Ie Average 4 5 Mm To Be Built
|
| Description |
Ttps Mech Ii Tm Ii Unit Iv Inspection And Rectification Of Epoxy Cladding Over The Condenser East West Front Side Tube Sheet And Water Box In The Reduced Thickness Area Rebuild The Claddings With Special Epoxy Putties Ie Average 4 5 Mm To Be Built
|
| Organisation | Government of Tamil Nadu |
| Tender Id | 2023_EB_345392_1 |
|
Reference Number |
SE/M-II /TTPS/ No.255/2023-24 |
| Tender Fee | 0 |
| EMD | 9500 |
| Tender Value | - |
| Place | O/o SE M II / TTPS |
| Link |
View Original Tender Notice
https://tntenders.gov.in |
| Start Date | July 17, 2023 23:30 |
| End Date |
Expired
24/07/2023
Expired 1141 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ttps mii tm ii unit iv inspection and rectification of epoxy cladding over the condenser east west front side tube sheet and water box in the reduced thickness area rebuild the claddings with special epoxy putties ie average 4 5 mm to be built up to
Ttps mii tm ii unit iv inspection and rectification of epoxy cladding over the condenser east west front side tube sheet and water box in the reduced thickness area rebuild the claddings with special epoxy putties ie average 4 5 mm to be built up to
Read moreTtps mech ii tm ii unit v inspection and rectification of epoxy cladding over the condenser water box and tube sheet east and west and rebuild the cladding with special epoxy putties ie average 4.5mm thick to be built up in the peeled off area of co
Ttps mech ii tm ii unit v inspection and rectification of epoxy cladding over the condenser water box and tube sheet east and west and rebuild the cladding with special epoxy putties ie average 4.5mm thick to be built up in the peeled off area of co
Read moreTtps mech ii tm ii unit iv inspection and rectification of epoxy cladding over the condenser water box and tube sheet east and west and rebuild the cladding with special epoxy putties ie average 4 5mm thick to be built up in the peeled off area of c
Ttps mech ii tm ii unit iv inspection and rectification of epoxy cladding over the condenser water box and tube sheet east and west and rebuild the cladding with special epoxy putties ie average 4 5mm thick to be built up in the peeled off area of c
Read moreTtps mech ii tm i unit ii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mate
Ttps mech ii tm i unit ii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mate
Read moreTtps mech ii tm i unit iii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mat
Ttps mech ii tm i unit iii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mat
Read moreTtps mech ii tm i unit i removal of deteriorated cladding over the inner surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mater
Ttps mech ii tm i unit i removal of deteriorated cladding over the inner surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mater
Read moreTtps mech ii tm i unit iii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mat
Ttps mech ii tm i unit iii removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mat
Read moreTtps mechii tm i uniti removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mate
Ttps mechii tm i uniti removal of deteriorated cladding over the surface of condenser east west cooling water inlet spool piece and outlet bends and rebuild the cladding with special epoxy putties to the required level including cost of mate
Read moreFixing of galvalume louver in the side claddings along grid h and a and providing side cladding sheets above 9mtr level along grid f in tm#5 at tnpl unit ii
Fixing of galvalume louver in the side claddings along grid h and a and providing side cladding sheets above 9mtr level along grid f in tm#5 at tnpl unit ii
Read moreSupply and replacing of galvalume sheet for the roof/cladding including dismantling etc in tps-ii
Supply and replacing of galvalume sheet for the roof/cladding including dismantling etc in tps-ii
Read moreof your Industry type