Tender Details
Check your funding eligibility in 2 minutes.
Answer a few questions and our team will contact you with your best options.
Particulars | Details |
---|---|
Title |
5 Purchase Of Favadi 200 Tasla 500 Gaiti 50 Panji 100 Ppe Kit 500 Antilarva 100 Liters Malathion Dust 25 Bags For Cleaning System
|
Description |
Purchase Of Favadi 200 Tasla 500 Gaiti 50 Panji 100 Ppe Kit 500 Antilarva 100 Liters Malathion Dust 25 Bags For Cleaning System
|
Organisation | Directorate of Local Bos UP | State Govt. and UT |
Tender Id | 2025_DOLBU_1008244_1 |
Reference Number |
57/NPPP/15th/TIED (5) 15-02-25 |
Tender Fee | 1359 |
EMD | 1.15 Lakh |
Tender Value | |
Place | Puwayaan |
Link | https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1807055 |
Start Date | February 20, 2025 15:30 |
End Date |
27/02/2025 ( Expired 108 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Fixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at divisional workshop miransahib
Fixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at divisional workshop miransahib
Read moreProviding lowering laying and jointing 100/150/200/250/300 mm dia. d.i. k-9 and 50/80/100/150 mm dia. g.i. pipe line and fixing of sluice valve for removing of leakages in ulhasnagar camp no. 4 and 5.
Providing lowering laying and jointing 100/150/200/250/300 mm dia. d.i. k-9 and 50/80/100/150 mm dia. g.i. pipe line and fixing of sluice valve for removing of leakages in ulhasnagar camp no. 4 and 5.
Read moreFor constn of steel cover shed size 100 50 6 ht retaining wall at purchase center siryewala mc bhagta bhai ka distt bathinda work code bti 25 036
For constn of steel cover shed size 100 50 6 ht retaining wall at purchase center siryewala mc bhagta bhai ka distt bathinda work code bti 25 036
Read moreFixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at divisional workshop
Fixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at divisional workshop
Read morePurchase of loader machine for dust cleaning for the citys cleanliness system.
Purchase of loader machine for dust cleaning for the citys cleanliness system.
Read moreFixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at workshop of ed-i parade jammu
Fixing the job contract (labour) for repair/reclamation of damaged distribution transformers (11kv/6.6kv/0.44kv) of different capacities viz 25 kva, 50/63 kva, 100 kva, 200/250 kva, 300 kva, 400 kva, 500 kva, 630 kva at workshop of ed-i parade jammu
Read more5-purchase of favadi 200 tasla 500 gaiti 50 panji 100 ppe kit 500 antilarva 100 liters malathion dust 25 bags for cleaning system
Purchase of favadi 200 tasla 500 gaiti 50 panji 100 ppe kit 500 antilarva 100 liters malathion dust 25 bags for cleaning system
Read moreSet of cable tie (nylon 6.6, colour: white) consisting of 7 items as per clw s spec. no.- clw/es/c- 54(alt.-b) and ers- poh/kgp drg. no.- se/kgp/el-765 (alt.-1) for cable bunching :- (1) cv 75 , l 75 mm x w 2.4 mm x th 0.80 mm = 500 nos/set. (2) cv 100, l 100 mm x w 2.5 mm x th 1.00 mm = 850 nos/set. (3) cv 150, l 150 mm x w 3.6 mm x th 1.15 mm = 550 nos/set. (4) cv 200, l 200 mm x w 4.8 mm x th 1.30 mm = 500nos/set. (5) cv 200 a, l 200 mm x w 3.6 mm x th 1.30 mm = 450 no s/set. (6) cv 300
For complete deion and other details, please refer to tender
Read moreLeucocyte depleted prp kit. technical specification 1.used for the separation of leucocyte poor platelet rich plasma. 2. lp-prp tube capacity: 25 ml. 3. extracts chamber: 2-6 ml sample capacity. 4. cellular concentrate : permits 25 - 28 ml. 5. kit box contain : (a) blood separation kit with three chamber. (b) 50 ml syringe with anti-coagulant. (c) butterfly cannula scalp vein set. (d) 18 gauge 4 inch 2 in quantity. (e) alcoholic swab. (f) antiseptic medicated band aid. 6. contains patented nan
For complete deion and other details, please refer to tender
Read more11kv 24v dc ptr lv vcbs with control & relay panels and cts of ratio 400-200-100/1-1a(with out differential protection): 11 kv, 3 pole, 1250 a,50 hz, 25 ka , porcelain clad pad type outdoor vacuum circuit breakers , with outdoor control and relay panels & current transformers , (detailed technical specification attached) . vcb shall be equipped with 24vdc operated outdoor type control and relay panels with 3 o/l & 1e/l idmt numerical relays and 3nos outdoor vcb mounted current transfor
For complete deion and other details, please refer to tender
Read moreof your Industry type