Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply, Erection , Testing & Commissioning Of Outdoor Type Transformer Of Capacity 33 Kv/0.415 Kv, 100 Kva, Copper Winding With All Safety Device , Ee Level 2, Other Standard All Accessories And Specification As Per Cege/Grc S Specification No: Ser/Elec/Gs/Description/Trans/4/Rev 0/Oct 2023, Attached Annexure A, Is:1180 Part 1 (2014) With Latest Amendment, Submission Of Type Test Report Of Above Rating Of Transformer And Gad/Gtp Along With Offer Is Mandatory.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106542176 |
|
Reference Number |
EA245262 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106542176/viewNitPdf_4792513.pdf |
| Start Date | December 02, 2024 22:11 |
| End Date |
Expired
30/12/2024
Expired 532 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Supply, erection , testing & commissioning of outdoor type transformer of capacity 33kv/0.415 kv, 100 kva, copper winding with all safety device , ee level 2, other standard all accessories and specification as per cege/grc s specification no: ser/elec/gs/description/trans/4/rev-0/oct 2023, attached annexure-a, is:1180 part 1 (2014) with latest amendment, submission of type test report of above rating of transformer and gad/gtp along with offer is mandatory.
For complete deion and other details, please refer to tender
Read moreSupply, erection , testing & commissioning of outdoor type transformer of capacity 33kv/0.415 kv, 100 kva, copper winding with all safety device , ee level 2, other standard all accessories and specification as per cege/grc s specification no: ser/elec/gs/description/trans/4/rev-0/oct 2023, attached annexure-a, is:1180 part 1 (2014) with latest amendment, submission of type test report of above rating of transformer and gad/gtp along with offer is mandatory.
For complete deion and other details, please refer to tender
Read moreSupply, testing & commissioning of 33/0.416kv, 500 kva outdoor type transformer with all safety device conforming to latest is spec. , losses of 1430w at 50 percent loading losses of 4200 w at 100 percent loading and standard accessories as per is 1180 part 1(2014) with latest amendment, submission of type test report of above rating of transformer and gad/gtp along with fer is mandatory, specification as per dy. cese/grc/ser attached in annexure a .
For complete deion and other details, please refer to tender
Read moreSupply, erection testing & commissioning of supply of lt control panel for distribution board consisting of copper bus bar with (i) 1 x 250a mccb tp, 36 ka as incoming and (ii) 2 x 100a tp mccb 25ka (iii) 4 x 63a tp mcb and (iv) 4 x 32 a tp 10 ka mcb as outgoing complete with protective gear, all metering including all other accessories e.t.c and specification conforming to cege/grc s specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar 2024.
For complete deion and other details, please refer to tender
Read moreSupply of 11/0.433 kv, 250 kva, 1 star previously level-2 now level-1 as per (is 1180 part-i) 2014 (amendment-4) copper wound distribution transformer bis certified with protection features
Supply of 11/0.433 kv, 250 kva, 1 star previously level-2 now level-1 as per (is 1180 part-i) 2014 (amendment-4) copper wound distribution transformer bis certified with protection features
Read moreSupply of 25 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1980
Supply of 25 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1980
Read moreSupply of 40 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1979
Supply of 40 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1979
Read moreSupply of supply of 16 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1981
Supply of supply of 16 kva, 11_0.433 kv, aluminium wound eel1 is 1180 1 2014 4 amendment star 1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn1981
Read moreSupply of 11/0.433 kv, 400 kva, 1 star previously level-2 now level-1 as per (is 1180 part-i) 2014 (amendment-4) copper wound distribution transformer bis certified with protection features
Supply of 11/0.433 kv, 400 kva, 1 star previously level-2 now level-1 as per (is 1180 part-i) 2014 (amendment-4) copper wound distribution transformer bis certified with protection features
Read moreSupply of 250 kva,11/0.416 kv, 3 phase, 50 hz, outdoor type distribution transformer complete, onan cooled, delta/star (dyn 11 group), copper wound , plinth mounted transformer with first fill of transformer oil and with standard fittings conforming to is:1180 (part-1)/2014 latest, energy efficiency: level 2 of table 6 of amendment no.4 march 2021 (details as per enclosed annexure- a ). guaranteed and other particulars as per enclosed annexure- b and drawing as per enclosed annexure- c . warr
For complete deion and other details, please refer to tender
Read moreof your Industry type