Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Ttps Operation Circle Oeii Fps Erection Of 125mtrs Of 200 Nb M.S Erw Pipe Line And 150 Nb Gate Valve 1 No For The Replacement Of Wornout/Damaged Existing Mulsifyre Pipe Lines Of Mvws System Near Unit Iv V Bottom Ash Area
|
| Description |
Ttps Operation Circle Oeii Fps Erection Of 125mtrs Of 200 Nb M.S Erw Pipe Line And 150 Nb Gate Valve 1 No For The Replacement Of Wornout/Damaged Existing Mulsifyre Pipe Lines Of Mvws System Near Unit Iv V Bottom Ash Area
|
| Organisation | Government of Tamil Nadu |
| Tender Id | 2023_EB_335435_1 |
|
Reference Number |
SE/O/TTPS/Spec.No.130/23-24 |
| Tender Fee | 0 |
| EMD | 2600 |
| Tender Value | |
| Place | O/o SE/O/TTPS |
| Link |
View Original Tender Notice
https://tntenders.gov.in |
| Start Date | July 04, 2023 21:30 |
| End Date |
Expired
19/07/2023
Expired 1064 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ttps operation circle oe ii erection of 150 mtrs 200 nb ms erw pipe lines for fire protection mulsifyre line from clarified water pump house to service building
Ttps operation circle oe ii erection of 150 mtrs 200 nb ms erw pipe lines for fire protection mulsifyre line from clarified water pump house to service building
Read moreTtps operation circle cad dismantling and replacement of wornout and punctured 200nb ms erw pipe of service water line from 300/200 reducer near scs unit v entrance of unit iv and v acw system
Ttps operation circle cad dismantling and replacement of wornout and punctured 200nb ms erw pipe of service water line from 300/200 reducer near scs unit v entrance of unit iv and v acw system
Read moreTtps operation circle cad reconditioning of wornout 1200 nb butterfly valve for cooling water pump house ii
Ttps operation circle cad reconditioning of wornout 1200 nb butterfly valve for cooling water pump house ii
Read moreTtps operation circle cad acwph dismantling and replacement of wornout and punctured 200nb ms erw pipe at cooling tower trough makeup line of unit i,ii and iii
Ttps operation circle cad acwph dismantling and replacement of wornout and punctured 200nb ms erw pipe at cooling tower trough makeup line of unit i,ii and iii
Read moreTtps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300/250/200/150/100 and 80 nb
Ttps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300/250/200/150/100 and 80 nb
Read moreTtps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300 250 200 150 100 and 80 nb
Ttps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300 250 200 150 100 and 80 nb
Read moreTtps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300/250/200/150/100 and 80 nb
Ttps operation circle o e ii fps overhauling of fire hydrant gate valves in various sizes 300/250/200/150/100 and 80 nb
Read moreTtps mech ii ahp dismantling the existing wornout 100 nb ss 316 pipe fittings and erection of new fittings in stage iii ash slurry pump house
Ttps mech ii ahp dismantling the existing wornout 100 nb ss 316 pipe fittings and erection of new fittings in stage iii ash slurry pump house
Read moreTtps operation circle mpm ii acp reconditioning of cooling tower c by replacing of fills, drift eliminators, spray header pipes, overhauling of 200 nb 150 nb gate valves, eroded discharge reducer pipe lines at unit iv v ac plant cooling tower etc
Ttps operation circle mpm ii acp reconditioning of cooling tower c by replacing of fills, drift eliminators, spray header pipes, overhauling of 200 nb 150 nb gate valves, eroded discharge reducer pipe lines at unit iv v ac plant cooling tower etc
Read moreTtps operation circle cad dismantling the wornout structure portion, fabrication and erection of m.s structure for self cleaning strainer 5a 5b of acw system unit v
Ttps operation circle cad dismantling the wornout structure portion, fabrication and erection of m.s structure for self cleaning strainer 5a 5b of acw system unit v
Read moreof your Industry type