Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
3 Pole Ac Contactor, 440 Vac, 800 Amp, Ac3, Operating Coil: 175 320 V Dc With Surge Suppressor Or Bid
|
| Description |
|
| Organisation | Department of Heavy Industry | Ministry of Heavy Industries and Public Enterprises |
| Tender Id | GEM/2025/B/5995683 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | February 25, 2025 21:43 |
| End Date |
Expired
08/03/2025
Expired 589 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read morePower contactor in open execution with auxillary contact 2no 2nc, 3 phase, 415 volts, 110 amps capa,power contactor siemens make ac3 duty 3 tf 33 00-0amo-llkw. coil voltage, 220 vac 50 hz, 1 no 1 nc,power contactor 70 amps rated current at 440 vac, coil voltage 220-250 volts ac with 2no 2nc auxilar
Power contactor in open execution with auxillary contact 2no 2nc, 3 phase, 415 volts, 110 amps capa,power contactor siemens make ac3 duty 3 tf 33 00-0amo-llkw. coil voltage, 220 vac 50 hz, 1 no 1 nc,power contactor 70 amps rated current at 440 vac, coil voltage 220-250 volts ac with 2no 2nc auxilar
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreHog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Hog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Read moreEarth leakage relay -110v rating elm8,moving contact,fixed contact,plug insulator with tube set,brass terminal with insulator dmc,power contactor 525v, 3p, 110a,coil 110v, operating,bushing insulator with stud,potential transformer 550-525-415v,0-8-12-24,110v,3p,core balance transformer,isolator 300 amps reversing,cable1.1kv,2c, copper, pvc, 1.5 mm2 flexible
Earth leakage relay -110v rating elm8,moving contact,fixed contact,plug insulator with tube set,brass terminal with insulator dmc,power contactor 525v, 3p, 110a,coil 110v, operating,bushing insulator with stud,potential transformer 550-525-415v,0-8-12-24,110v,3p,core balance transformer,isolator 300 amps reversing,cable1.1kv,2c, copper, pvc, 1.5 mm2 flexible
Read moreContactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Read moreFeeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de
Read moreWorking and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read moreof your Industry type