Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Pacer With Mask For Child [Srphc82337065 Spacer With Mask For Children.1)it Should Be Suitable For Use For Infants And Children.2)the Minimum Capacity Of The Holding Chamber Should Be Approximately 250 Cc(ml).3)the Holding Chamber Should Have A Valve To Prevent Rebreathing Of The Exhaled Air.4)should Be Made Of Polymer /Polycarbonated Material.5)should Have A Mask Of Pediatric Size Suitable For Covering The Nose And Mouth Of The Infant And Children.6)should Be Compatible With The Mdi Which Is B
|
| Description |
Pacer With Mask For Child [Srphc82337065 Spacer With Mask For Children.1)it Should Be Suitable For Use For Infants And Children.2)the Minimum Capacity Of The Holding Chamber Should Be Approximately 250 Cc(ml).3)the Holding Chamber Should Have A Valve To Prevent Rebreathing Of The Exhaled Air.4)should Be Made Of Polymer /Polycarbonated Material.5)should Have A Mask Of Pediatric Size Suitable For Covering The Nose And Mouth Of The Infant And Children.6)should Be Compatible With The Mdi Which Is B
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | September 25, 2026 18:24 |
| End Date |
Open
06/11/2026
22 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read moreSupply and delivery of 13000 mtr. 6mm silicone coated fiber glass insulation cover for 5 mm gi wire insulation grade 4kv make joint mask should have erda cpri test certificate
Supply and delivery of 13000 mtr. 6mm silicone coated fiber glass insulation cover for 5 mm gi wire insulation grade 4kv make joint mask should have erda cpri test certificate
Read moreNeedle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Read moreOlonic metal uncovered st [srphc82336085-colonic metal uncovered stent should be made of alloy material to allow greater flexibility and use in tortuous anatomy. should have various lengths 6 or 8 or 10cm. should have a 30mm flare and 25mm body and reconstrainable even after 70 percent of deployment.] ,ontrolled radial expansio [srphc82336090-controlled radial expansion esophageal balloon dilator: 1. balloon made of pebax (polyether block amide or peba is a thermoplastic elastomer), a non-co
Olonic metal uncovered st [srphc82336085-colonic metal uncovered stent should be made of alloy material to allow greater flexibility and use in tortuous anatomy. should have various lengths 6 or 8 or 10cm. should have a 30mm flare and 25mm body and reconstrainable even after 70 percent of deployment.] ,ontrolled radial expansio [srphc82336090-controlled radial expansion esophageal balloon dilator: 1. balloon made of pebax (polyether block amide or peba is a thermoplastic elastomer), a non-co
Read more1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
Read moreIntubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu
Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu
Read moreCab door lock for vande bharat dtc coaches as per south co.part no.r3-99-61-20 or equivalent to south co.part no. r3-99-61-20 suitable for vande bharat dtc coaches. note:- 1). the door lock should be suitable for version 2 rake of vande bharat. 2). the shape, size and material should be similar to the south co. part no.r3-99-61-20.
Cab door lock for vande bharat dtc coaches as per south co.part no.r3-99-61-20 or equivalent to south co.part no. r3-99-61-20 suitable for vande bharat dtc coaches. note:- 1). the door lock should be suitable for version 2 rake of vande bharat. 2). the shape, size and material should be similar to the south co. part no.r3-99-61-20.
Read moreDisposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Read moreOne piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
Read moreReducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Reducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Read moreof your Industry type