| Title |
The Nitinol Core Coronary Wire Width Should Be 0.014 In Diameter And Length Of 180 Cm Or More. The Tip Weight Should Be Less Than One Gram. Should Have Hydrophilic Coating. Should Have 1:1 Torquability. Should Be Compatible With Dock Extension Wire
|
| Description |
The Nitinol Core Coronary Wire Width Should Be 0.014 In Diameter And Length Of 180 Cm Or More. The Tip Weight Should Be Less Than One Gram. Should Have Hydrophilic Coating. Should Have 1:1 Torquability. Should Be Compatible With Dock Extension Wire
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 09, 2026 18:00 |
| End Date |
Open
01/12/2026
47 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Rota wire rotablation guide wire,covered stents various sizes,jelco needle assorted sizes,femoral puncture needle 18g x 7cm,caravel microcatheter,ptca balloon dilatation cathter rapid exchange assorted sizes,hydrophilic nitinol wire with soft tip load of less than 1gm and shaping ribbon design 190cm bmw,hydrophilic guide wires terumo angled tip 0 point 035 150cms,hydrophilic guide wires terumo angled tip 0 point 035 x 260cms exchange length
Rota wire rotablation guide wire,covered stents various sizes,jelco needle assorted sizes,femoral puncture needle 18g x 7cm,caravel microcatheter,ptca balloon dilatation cathter rapid exchange assorted sizes,hydrophilic nitinol wire with soft tip load of less than 1gm and shaping ribbon design 190cm bmw,hydrophilic guide wires terumo angled tip 0 point 035 150cms,hydrophilic guide wires terumo angled tip 0 point 035 x 260cms exchange length
Read moreCoronary guide wire slip coat over spring coil with greater tip flexiblity and support,coronary guide wire silicon coating over spring coil with extra support
Coronary guide wire slip coat over spring coil with greater tip flexiblity and support,coronary guide wire silicon coating over spring coil with extra support
Read moreHq_med_cath_gte_zrc_zonal rate contract for supply of ph no:.(158300) ptca guide wire, tip load 0.6gf, tip radiopaque length 16cm, spring coil length 16cm, polymer sleeve with slip coat (hydrophilic coating) 17cm, 0.014 inch guide wire with distally tampered tip of 3cms of diameter 0.01 inch (0.26mm), composite core construction with multiple wire components comprising of rope coil
Hq_med_cath_gte_zrc_zonal rate contract for supply of ph no:.(158300) ptca guide wire, tip load 0.6gf, tip radiopaque length 16cm, spring coil length 16cm, polymer sleeve with slip coat (hydrophilic coating) 17cm, 0.014 inch guide wire with distally tampered tip of 3cms of diameter 0.01 inch (0.26mm), composite core construction with multiple wire components comprising of rope coil
Read more1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
Read moreIntubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu
Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu
Read moreOne piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
Read moreSupply and delivery of 13000 mtr. 6mm silicone coated fiber glass insulation cover for 5 mm gi wire insulation grade 4kv make joint mask should have erda cpri test certificate
Supply and delivery of 13000 mtr. 6mm silicone coated fiber glass insulation cover for 5 mm gi wire insulation grade 4kv make joint mask should have erda cpri test certificate
Read moreNeedle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Read moreRapid exchange thrombus aspiration catheter system,vascular closure device,6f radial sheath,femoral sheath 6f,inflation device indeflator kit for angioplasty,ptca guide catheter speciality curves,rapid exchange cutting balloon micro surgical dilation device assorted size,semi complaint ptca balloon catheter with corrugated surface and low profile wig shape design,micro puncture set,coronary guide wire slip coat over spring coil with greater tip flexibility and support,coronary guide wire silicon coating over the spring coil with extra support,coronary guide wire slip coat coating over polymer jacket with excellent lubricity and trackability in tortous vessel tapered tip,intra aortic balloon catheter with insertion kit and connector assorted size
Rapid exchange thrombus aspiration catheter system,vascular closure device,6f radial sheath,femoral sheath 6f,inflation device indeflator kit for angioplasty,ptca guide catheter speciality curves,rapid exchange cutting balloon micro surgical dilation device assorted size,semi complaint ptca balloon catheter with corrugated surface and low profile wig shape design,micro puncture set,coronary guide wire slip coat over spring coil with greater tip flexibility and support,coronary guide wire silicon coating over the spring coil with extra support,coronary guide wire slip coat coating over polymer jacket with excellent lubricity and trackability in tortous vessel tapered tip,intra aortic balloon catheter with insertion kit and connector assorted size
Read more1) hemoclip rotatable should be a) pre-loaded ready to use b) multiple times reopening capability c) wide jaw span greater than and equal to 16mm d) length 150 to 200cm and 360 degree rotation and 1:1 movement, 2) injection gold probe consists of : a) 7fr injection gold probe combined with sclerotherapy needle and firm catheter shaft b) should have separate irrigation channel, compatible with a 2.8mm working channel c) working length more than 160cm and have a ceramic and gold tip, 3) hemospra
1) hemoclip rotatable should be a) pre-loaded ready to use b) multiple times reopening capability c) wide jaw span greater than and equal to 16mm d) length 150 to 200cm and 360 degree rotation and 1:1 movement, 2) injection gold probe consists of : a) 7fr injection gold probe combined with sclerotherapy needle and firm catheter shaft b) should have separate irrigation channel, compatible with a 2.8mm working channel c) working length more than 160cm and have a ceramic and gold tip, 3) hemospra