Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
28/Eudc In/2024 25
|
| Description |
Testing Of Power Transformers, 33 Kv Incoming Breakers And Panel, 33 Kv Transformers Breakers And Transformer Protection Panel, 11 Kv Incoming/ Outgoing Breaker Panel Under The Jurisdiction Of Ee, Eutd Indira Nagar, Gomti Nagar Zone, Lucknow.
|
| Organisation | Madhyanchal Vidyut Vitran Nigam Ltd | State Govt. and UT |
| Tender Id | 2025_MVVNL_992377_1 |
|
Reference Number |
28/EUDC-IN/2024-25 |
| Tender Fee | 1180 |
| EMD | 13500 |
| Tender Value | - |
| Place | 33/11 KV S/S HAL POWER HOUSE FAIZABAD ROAD LUCKNOW |
| Link |
View Original Tender Notice
https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1753834 |
| Start Date | January 11, 2025 15:30 |
| End Date |
Expired
21/01/2025
Expired 634 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairs maintenance to ht 33kv sf6 breakers, 11 kv vcbs and rmus, 33 /11 kv power transformers, 11 kv/433 volts distribution transformers, ht cable, joint kits along with connected allied works at nstl under age i rnd nstl, visakhapatnam
Repairs maintenance to ht 33kv sf6 breakers, 11 kv vcbs and rmus, 33 /11 kv power transformers, 11 kv/433 volts distribution transformers, ht cable, joint kits along with connected allied works at nstl under age i rnd nstl, visakhapatnam
Read morePreventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreMaintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Read moreC and s c and s acb 1250a 3p edo, without relay,c and s c and s acb 1600a 3p edo without relay,c and s c and s acb 800a 3p edo without relay,c and s 7no plus 7nc auxiliary contacts for c and s make acb,c and s dowell pin for c and s make acb,c and s sic block for c and s make breaker,bch reputed make connectwell end plate ep cdttu,bch delta door lock,bch reputed make key for delta lock,bch reputed make knob type door lock and key,bch power incoming contact,areva areva vtt11 220v dc 1 10 s 2no plus 2nc plus resistor,areva areva undervoltage relay vagm22af171g 1dv 110v ac 1no plus 2nc,bch 8 mm insulator red for outgoing feeder busbar support for cable,bch power contactor 2no plus 2nc 220v ac ce15f series ac 3 32a 15 kw,bch rack in rack out handle for draw out feeders breaker,bch bch control transformer 3 kva primary 415v,bch bch control transformer 10 kva primary 415v,bch reputed make service test limit switch,bch reputed make module jaw contact support stab module nuts and bolts copper bus 4 cm insulator and i
C and s c and s acb 1250a 3p edo, without relay,c and s c and s acb 1600a 3p edo without relay,c and s c and s acb 800a 3p edo without relay,c and s 7no plus 7nc auxiliary contacts for c and s make acb,c and s dowell pin for c and s make acb,c and s sic block for c and s make breaker,bch reputed make connectwell end plate ep cdttu,bch delta door lock,bch reputed make key for delta lock,bch reputed make knob type door lock and key,bch power incoming contact,areva areva vtt11 220v dc 1 10 s 2no plus 2nc plus resistor,areva areva undervoltage relay vagm22af171g 1dv 110v ac 1no plus 2nc,bch 8 mm insulator red for outgoing feeder busbar support for cable,bch power contactor 2no plus 2nc 220v ac ce15f series ac 3 32a 15 kw,bch rack in rack out handle for draw out feeders breaker,bch bch control transformer 3 kva primary 415v,bch bch control transformer 10 kva primary 415v,bch reputed make service test limit switch,bch reputed make module jaw contact support stab module nuts and bolts copper bus 4 cm insulator and i
Read more11 kv incoming outgoing panel (icog) as per attached description,3.3 kv incoming outgoing panel (ic
Read more
Icog (incoming and outgoing type) panel with vcb (vacuum circuit breaker),decommission, un-install,
Read more
33kv ht panels, lt breakers, distribution transformers and capacitor banks along with control panel
Read more
Maintenance of 11 kv vcb incoming and outgoing panel edd-ii
Maintenance of 11 kv vcb incoming and outgoing panel edd-ii
Read moreof your Industry type