Particulars | Details |
---|---|
Title |
Single Bottle Vcb (Single Interrupter Vacuum Circuit Breaker Type 22 Cb Schneider Make), Rated Voltage: 25 Kv Single Phase Rated Current: 1000 Amp (Rms), Rated Frequency:50 Hz, Short Time Current:16 K Amp Rms (400 Mva), Rated Short Circuit Making Current: 40 K Amp Peak, Rated Power Frequency Voltage (Dry & Wet):75 Kv Rms, No. Of Phase: One, Total Weight:125 Kg (Approx.).
Note: 1. Fixing Arrangement Of Vcb Should Be Same As Existing Schneider Make Vcb Drawing No. Clw/Es/Sk 8/C 47/I.
2. The Locati
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106603282 |
Reference Number |
68245449D |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Jabalpur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/022025/106603282/viewNitPdf_4860986.pdf |
Start Date | February 08, 2025 19:07 |
End Date |
21/02/2025 ( Expired 141 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Surge arrester, class-4, rated voltage:40 kv, continuous operating voltage:32 kv, min. creepage distance: 1470 mm, frequency: 15-62 hz. rdso specification rdso/pe/spec/emu/0196 alongwith dimensions, terminal hardware and mounting hardware as per icf drg. no.icf/sk3-7-2-071 generally confirm to clw spec. clw/es/3/0016 alt. b digitized suitable to vb rates.
For complete deion and other details, please refer to tender
Read moreSingle bottle vcb (single interrupter vacuum circuit breaker type 22 cb schneider make), rated voltage: 25 kv single phase rated current: 1000 amp (rms), rated frequency:50 hz, short time current:16 kamp rms (400 mva), rated short circuit making current: 40 kamp peak, rated power frequency voltage (dry & wet):75 kv rms, no. of phase: one, total weight:125 kg (approx.). note: 1. fixing arrangement of vcb should be same as existing schneider make vcb drawing no. clw/es/sk-8/c-47/i. 2. the locati
For complete deion and other details, please refer to tender
Read moreSingle bottle vcb (single interrupter vaccum circuit breaker type 22 cb schneider make) rated voltage: 25 kv single phase rated current: 1000amp (rms) rated frequency:50 hz short time current:16 kamp rms (400 mva) rated short circuit makingcurrent:400 kamp peak rated power frequency voltage (dry & wet):75 kv rms no. of phase: one total weight:125 kg (approx.)
For complete deion and other details, please refer to tender
Read morePortable single operated rectifier type conventional dc arc welding set-600 ampere capacity suitable for manual arc welding process with warranty/guarantee and test certificate. technical specification as given below: 1. maximum hand welding current 60 percent duty cycle 600a and minimum hand welding current 60 percent duty cycle: 120 a 2. open circuit voltage : 70v (max) and operating arc voltage: 25-44 volt. 3. 3-phase 50 hz, rated input voltage: 3 tapings- 380/415/440 volts. 4. type
For complete deion and other details, please refer to tender
Read moreSurge arrester, class -3, rated voltage: 42kv, continuous operating voltage: 34 kv, min. creepage distance: 1470 mm, frequency: 15-62 hz. drg. no. and specification: rdso specification rdso/pe/spec/emu/0196. along with dimensions, terminal hardware and mounting hardware as per icf drg. no. icf/sk3 7-2-071. generally confirm to clw spec. clw/es /3/0016 alt b digitized suitable to vb rakes.
For complete deion and other details, please refer to tender
Read morePotential transformer 33/36 kv as per is:3156:1992 latest, single phase with connector, 50 hz, ratio-33/36kv/v3/110//v3, class 1.0, outdoor - dual purpose voltage transformer - oil immersed, no. of secondary - 2, system earthing - isolated neutral system, e class insulation, copper winding, power frequency withstand voltage - kv (rms) - 70, lightning impulse withstand voltage - list 1 - kv (peak) ? 40, lightning impulse withstand voltage - list 2 - kv (peak- 170. rated output at a power factor
For complete deion and other details, please refer to tender
Read moreSurge arrester, class -3, rated voltage: 42kv, continuous operating voltage: 34 kv, min. creepage distance: 1470 mm, frequency: 15-62 hz. drg. no. and specification: rdso specification rdso/pe/spec/emu/0196. along with dimensions, terminal hardware and mounting hardware as per icf drg. no. icf/sk3 7-2-071. generally confirm to clw spec. clw/es /3/0016 alt b digitized suitable to vb rakes.
For complete deion and other details, please refer to tender
Read more63 amps miniature circuit breaker (mcb), [63 amps miniature circuit breaker (mcb), triple pole, type c63, breaking/short circuit capacity: 10000a, 240/415v ac, 50 hz supply, rated current: 63 amps, conforms to is/iec: 60898-1. make: cona or c&s electric or havells or l&t or anchor or bch or schneider or abb or indoasian.]
For complete deion and other details, please refer to tender
Read more[single bottle vaccum circuit breaker (vcb) schneider make (type-22cb )or equivalent along with matching accessories for 3-phase medha make memu motor coach. as per clw s sepc. no. clw/es/c-47 alt.g or latest. ]
For complete deion and other details, please refer to tender
Read more32 amps miniature circuit breaker (mcb), [32 amps miniature circuit breaker (mcb), triple pole, type c32, breaking/short circuit capacity: 10000a, 240/415v ac, 50 hz supply, rated current: 32 amps, conforms to is/iec: 60898-1. make: cona or c&s electric or havells or l&t or anchor or bch or schneider or abb or indoasian.]
For complete deion and other details, please refer to tender
Read moreof your Industry type