Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply Of Transformer Cooling Fan Out Door Type Working On 230 Volts Single Phase Ac Supply Suitable For Fixing On Radiator Of 21.6 Mva Traction Transformer, 450 Mm Sweep, 1400 Rpm With 380 Mm Length Fixing Bolt, Nut, Clamp And Back Guard. Minimum Free Air Flow Should Be 7000 Cubic Metre Per Hour And Direction Of Air Flow Should Be From Motor End To Blade End.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106494610 |
|
Reference Number |
97245937A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Chennai |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/102024/106494610/viewNitPdf_4738788.pdf |
| Start Date | October 10, 2024 15:37 |
| End Date |
Expired
21/10/2024
Expired 727 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.
Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.
Read moreWire wound resistor 4.7 ohms 1000w, size 50 mm outer dia and resistor length 380 mm with suitable fixing clamp item to be supplied along with fixing clamps. height of fixing clamp should beabove 35 mm.
Wire wound resistor 4.7 ohms 1000w, size 50 mm outer dia and resistor length 380 mm with suitable fixing clamp item to be supplied along with fixing clamps. height of fixing clamp should beabove 35 mm.
Read moreWater flow meter, mechanical with calib [ water flow meter, mechanical with calibration certificate from nabl lab, is:2373 or latest, size - 50mm. least count - 10 liter, water meter should be enclosed typewith brass body cover with mettalic gears]
Water flow meter, mechanical with calib [ water flow meter, mechanical with calibration certificate from nabl lab, is:2373 or latest, size - 50mm. least count - 10 liter, water meter should be enclosed typewith brass body cover with mettalic gears]
Read moreTrochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Trochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Read moreWater flow meter,size:-50 mm.as per is:2373 or latest, least count-10 ltrs, water meter should be enclosed type with brass body cover with metallic gears. firm should provide calibration certificate from nabl approved lab .make:-jaldhara or similar
Water flow meter,size:-50 mm.as per is:2373 or latest, least count-10 ltrs, water meter should be enclosed type with brass body cover with metallic gears. firm should provide calibration certificate from nabl approved lab .make:-jaldhara or similar
Read moreNeedle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Read moreHiv (rapid/spot) test kit. spec: 1. kit should be able to simultaneously and differentially detect both antigen (hiv-1 & p-24) and antibodies for hiv on the same device. 2. kit should follow immunochromatography principle by using flowthrough or lateral flow technology. 3. kit should be able to detect seronegative hiv cases. 4. kit should detect gr o and sub type c strains of hiv, which is most prevalent in india. 5. kit should follow proper washing steps for clear interpretation of results. 6
Hiv (rapid/spot) test kit. spec: 1. kit should be able to simultaneously and differentially detect both antigen (hiv-1 & p-24) and antibodies for hiv on the same device. 2. kit should follow immunochromatography principle by using flowthrough or lateral flow technology. 3. kit should be able to detect seronegative hiv cases. 4. kit should detect gr o and sub type c strains of hiv, which is most prevalent in india. 5. kit should follow proper washing steps for clear interpretation of results. 6
Read morePolyester double layered heavy duty duplex webbing sling reinforced eye at both end (loop) capacity - 2ton, length - 3 meters, having anti abrasive sleeve 0.5 meter long against protection from rough surface as per is:15041-2025. (note - sling should be tested by govt. approved laboratory. certificate to be provided at the time of supply. all sling should have individual metal tag on which mfg year and serial number must be punch
Polyester double layered heavy duty duplex webbing sling reinforced eye at both end (loop) capacity - 2ton, length - 3 meters, having anti abrasive sleeve 0.5 meter long against protection from rough surface as per is:15041-2025. (note - sling should be tested by govt. approved laboratory. certificate to be provided at the time of supply. all sling should have individual metal tag on which mfg year and serial number must be punch
Read moreHose connection 3/8 x 1600 mm long to icf drg no icf/sk-3-5-517,alt-u/18 item no 2 .both end should be swivel end with three nylon washers to icf drg no icf/sk-3-5-263, alt-nil, item no 3.
Hose connection 3/8 x 1600 mm long to icf drg no icf/sk-3-5-517,alt-u/18 item no 2 .both end should be swivel end with three nylon washers to icf drg no icf/sk-3-5-263, alt-nil, item no 3.
Read more1) autoclave tape roll to indicate endpoint for steam steriliser size: 19mm, 2) chemical indicator for steam sterilzation. verifies time, temperature, steam. should be convenient to use. (autoclave label) 3m cat no.comply 1250 or similar unit:strip, 3) ethylene oxide gas tape roll to indicate endpoint of eto. size 18mm/19mm x 50m paper should be of good quality & 4) cartridge containing 200 grams of 100 percent ethylene oxide gas compatible for use in eto gas sterilizer of 7,8,and 10 cubic fe
1) autoclave tape roll to indicate endpoint for steam steriliser size: 19mm, 2) chemical indicator for steam sterilzation. verifies time, temperature, steam. should be convenient to use. (autoclave label) 3m cat no.comply 1250 or similar unit:strip, 3) ethylene oxide gas tape roll to indicate endpoint of eto. size 18mm/19mm x 50m paper should be of good quality & 4) cartridge containing 200 grams of 100 percent ethylene oxide gas compatible for use in eto gas sterilizer of 7,8,and 10 cubic fe
Read moreof your Industry type