Tender Details
Particulars | Details |
---|---|
Title |
Supply Of Power Supply Unit With Following Spec. 1) Input Av 220v To 260v2) Output 3 Volt To 4.5 Volt Dc/500ma 3) Battery 12v/7 Ah Mf 4) Fuse Protection Input Ac And Output Dc 5) Led Indication : Input Ac, Output Dc And 12 Volt Battery Ok 6) Switches On/Off System Dc 3 Volt To 4.5 Volt Output 7) Container Power Supply Unit Will Be Having Partition One For Circuitry And One For Battery. Make Nodm, Epsilon , Bentron, Anuvidyut, Indisco & Technoor Similar.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106419461 |
Reference Number |
96245431A |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Bilaspur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/082024/106419461/viewNitPdf_4657345.pdf |
Start Date | July 25, 2024 23:56 |
End Date |
05/08/2024 ( Expired 261 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Switch mode power supply, input voltage 3 phase 415 v ac output voltage 24v dc: 20 amps make; delt
Read more
Emergency battery charger unit, capacity 10a, input voltage 415v ac, 3 phase, output 24v dc confirming to icf spec. no. icf/elec/841, rev. a suitable for garib rath type ac coaches.
For complete deion and other details, please refer to tender
Read moreSupply of single phase 2 kva inverter with suitable battery bank, pure sinewave ac output in inverter mode - 220 volt/- 10-volt, 50 hz., dc bus voltage - 24 volt, all other specifications/deions as golden parameter, make - luminous, exide, microtek or similar
For complete deion and other details, please refer to tender
Read moreTest bench for master controller for thr [test bench for master controller for three phase ac locos with facilities as given below. [1] facility for checking of cam switch conditions with respect to angle transmitters output current with the help of led indication. [2] provision of one digital ma meter to measure angle transmitter current. [3] provision of checking reverser switch status in forward, natural & reverse conditions. [4] provision of variable dc power supply with digital voltmeter
For complete deion and other details, please refer to tender
Read moreMultifunction meter with user programmable ct/pt ratio 5a or 1a ct input for lv or hv networks, inputvoltage 100-600 v- l, auxiliary supply 12 - 60v ac/dc ,display :high brightness 3 line 4 digits led, size:96x96mm, flush mount type, accuracy class :1.0,measurement and displayparameters : vaf, kw, kvar, kva,kwh, kvarh,kvah, pf, pa, mm,nc,thd,run hours and on hours similar to rishabh make model no: rish master 3430/socomec diris a 40 suitable for mounting in switch board cabinet of lhb power c
For complete deion and other details, please refer to tender
Read moreMcb millivolt test unit 100a, model no. mvdts100 of m/s. rectifiers & electronics make or its similar as per the following specification details: 1) dc output current : 0 - 100 amp continuous. 2) dc output voltage : 0 - 6v. 3) input voltage : 200/ 250 v. 4) input current : 3.5 a. 5) ac ripple in dc supply with 5 percent . 6) input on/ off switch and input on indicator. 7) 96 sq. mm ampere meter of 0 - 200a to indicate output current. 8) 1.5 meter lead with crocodile clip. 9) mv meter
For complete deion and other details, please refer to tender
Read moreInsulation monitoring relay. (imr) to monitor 3 phase power supply of voltage range 110volt ac , measuring range 1-100 k ohm, contrel voltage 24-240 volt ac /dc output ic/0 (spdt)contact system leakage capacitance 10 micro farad as per control model no ir 140y-4,ri- r 22(or)abb model no cm. iws.is (or)schneider model no vigil ohm/im10 (or) siemens model no 3ug4581-1aw30 (or) dold model no il5880 (or)bender (or) woka. suitable for installation in s1a6 as per rdso /pe/spec/ac/0184-2015 (rev 1)
For complete deion and other details, please refer to tender
Read moreMig/mag welding machine with self adjusting arcs (specs :output current of 400 a at 60 percentage and 309 a at 100 percentage duty cycle with input voltage 415 /- 15 percentage volt, 3 phase, 50 hz ac supply, efficiency 86 percentage or better, power factor 0.9 or better, protection class ip21, open circuit voltage 16-34 volts suitable for wire diameter 0.8- 1.6 mm and wire feed speed 1-25 mtrs. per minute, weight 50 kgs approx)
For complete deion and other details, please refer to tender
Read moreSupply of smps suitable to operate in 230 v 50 hz ac supply with output 24v dc 10 amps current conforming to is 15885 (part 2/sec 13)2012 1.working output voltage :230vac input 50hz 2.output : 24 v dc 10a 3.output over voltage protection : yes 4.over current protection : yes 5.short circuit protection :yes 6.surge protected outputs :yes 7.dc output indication :led indication 8.dimension :length: 180mm,breadth: 110mm, height: 50mm 9.self-cooling fan :yes 10.mounting type :panel mounting.
For complete deion and other details, please refer to tender
Read moreTest bench for master controller for 3 phase ac locos, with following specification (1) facility of checking of cam switch conditions with respect to angle to angle transmitters output current with the help of led indication. (2) provision of one digital ma meter to measure angle transmitter current ( range 0-30mamp. with 0.25 percent accuracy ) (3) provision of checking reverser switch status in forward, neutral and reverse conditions. (4) provisions of in- built variable dc power supply &
For complete deion and other details, please refer to tender
Read moreof your Industry type