Supply & Installation Of Aerosol Based Fire Detection & Suppression System Cartridge For Sg Ac Coaches. The Cartridge Contains 01 No. Of 40 Gm For Power Panel, 02 No. Of 15 Gm For Rmpu Control Panel & 02 No. Of 10 Gm For Inverter Panel Of Sg Ac Coaches As Per The Technical Requirement In Annexure G1 Of Rdso Specification No. Rdso/Pe/Spec/Ac/0192 2018(rev 1) & Rdso Letter No. El/7.1.108/Mssbc/Main Dated 12.05.2022. All Necessary Modification, Clamping Arrangement & Accessories Required For Instal
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106265345 |
|
Reference Number |
AP235397C |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Guwahati |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/022024/106265345/viewNitPdf_4478944.pdf |
| Start Date | February 10, 2024 10:00 |
| End Date |
Expired
16/02/2024
Expired 972 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Snap lock non lockable with finger pull equivalent to dirak part no. 353- 2070.04-00000 of dirak suitable for door leaves of switch board cabinet of lhb eog ac coaches as per specification no. rdso/pe/spec/ac /0184-2015 (rev 0) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021. make-dirak/southco/arihant/ darshana only as per sr. no. 78 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021
Snap lock non lockable with finger pull equivalent to dirak part no. 353- 2070.04-00000 of dirak suitable for door leaves of switch board cabinet of lhb eog ac coaches as per specification no. rdso/pe/spec/ac /0184-2015 (rev 0) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021. make-dirak/southco/arihant/ darshana only as per sr. no. 78 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021
Read moreRod latch suitable for closing of door of switch board cabinet control panel of lhb type a.c. coaches 5116877-52168944486 and as per specification no. rdso/pe/spec/ac /0184-2015 (rev 2) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021, accepted make- dirak part no 208-9025.00-00000, arihant, southco, darshana.
Rod latch suitable for closing of door of switch board cabinet control panel of lhb type a.c. coaches 5116877-52168944486 and as per specification no. rdso/pe/spec/ac /0184-2015 (rev 2) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021, accepted make- dirak part no 208-9025.00-00000, arihant, southco, darshana.
Read moreContactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read moreDc to dc converter for switch board cabinet of lhb ac coaches-110/24 v, 240w,10a. as per rdso letter no.( update on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoenix-trio-ps-2g/1ac/24dc/10-2903149 only. on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoe
Dc to dc converter for switch board cabinet of lhb ac coaches-110/24 v, 240w,10a. as per rdso letter no.( update on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoenix-trio-ps-2g/1ac/24dc/10-2903149 only. on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoe
Read moreMpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Read moreMotor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Read moreDin type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Read moreDisconnecting and earthing device, 8 pole, 2 way, without off, on load 125 amps at 1000v ac, 2no+2nc and with heavy handle and pad locking arrangement in one position, mounted in a stainless steel enclosure, suitable for ac 23 duty and conforming to iec60947 maximum depth including handle 480mm suitable for switch board cabinet of lhb ac coach as per rdso letter no. el/7.1.108/mssbc dated 17.09.2021 & rdso letter no. el/6.8.21/tl-ac committee dated 11.05.2023 and rdso specification no. rdso/pe
Disconnecting and earthing device, 8 pole, 2 way, without off, on load 125 amps at 1000v ac, 2no+2nc and with heavy handle and pad locking arrangement in one position, mounted in a stainless steel enclosure, suitable for ac 23 duty and conforming to iec60947 maximum depth including handle 480mm suitable for switch board cabinet of lhb ac coach as per rdso letter no. el/7.1.108/mssbc dated 17.09.2021 & rdso letter no. el/6.8.21/tl-ac committee dated 11.05.2023 and rdso specification no. rdso/pe
Read moreHigh voltage hrc fuse of 125 amps, 1000 v ac, breaking capacity 80 ka, type nh1l as per rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dated 17.09.2021 or latest, to siba cat. no. 2028003.125, eaton bussman cat. no. 125nh1lir-1000, eti cat. no. 4182495, efen, ferraz and siemens makes only acceptable. note: regular authorized dealers shall submit authorization letter from oems along with the offer.
High voltage hrc fuse of 125 amps, 1000 v ac, breaking capacity 80 ka, type nh1l as per rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dated 17.09.2021 or latest, to siba cat. no. 2028003.125, eaton bussman cat. no. 125nh1lir-1000, eti cat. no. 4182495, efen, ferraz and siemens makes only acceptable. note: regular authorized dealers shall submit authorization letter from oems along with the offer.
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,