Tender Details

Particulars Details
Title
Supply & Installation Of Aerosol Fire Detection And Suppression System Cartridge 100 Gm100 Gm,Total2 Pieces As Per The Technical Requirement Specifiedin Annexure G1 Of Rdso Specn. Rdso/Pe/Spec/Ac/0192 2018(rev.1) And Rdso Letterno.El/7.1.108/Mssbc Dt.17.09.2021. This Shall Be Installed In Sbc Of Various Type Of Coaches. All Necessary Modification, Clamping Arrangement And Accessories Required For Installation Of This Item Shall Be With The Scope Of This Supplier. Eligibility Criteria: 1) Rdso
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106241640
Reference
Number
80245088
Tender Fee 0
EMD 0
Tender Value -
Place Gorakhpur
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/012024/106241640/viewNitPdf_4451618.pdf

Start Date January 11, 2024 16:35
End Date
Expired 22/01/2024

Expired 1000 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Snap lock non lockable with finger pull equivalent to dirak part no. 353- 2070.04-00000 of dirak suitable for door leaves of switch board cabinet of lhb eog ac coaches as per specification no. rdso/pe/spec/ac /0184-2015 (rev 0) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021. make-dirak/southco/arihant/ darshana only as per sr. no. 78 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021

Snap lock non lockable with finger pull equivalent to dirak part no. 353- 2070.04-00000 of dirak suitable for door leaves of switch board cabinet of lhb eog ac coaches as per specification no. rdso/pe/spec/ac /0184-2015 (rev 0) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021. make-dirak/southco/arihant/ darshana only as per sr. no. 78 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021

Read more
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.

Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.

Read more
Rod latch suitable for closing of door of switch board cabinet control panel of lhb type a.c. coaches 5116877-52168944486 and as per specification no. rdso/pe/spec/ac /0184-2015 (rev 2) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021, accepted make- dirak part no 208-9025.00-00000, arihant, southco, darshana.

Rod latch suitable for closing of door of switch board cabinet control panel of lhb type a.c. coaches 5116877-52168944486 and as per specification no. rdso/pe/spec/ac /0184-2015 (rev 2) & rdso letter no. el/7.1.108/ mssbc dated 17.09.2021, accepted make- dirak part no 208-9025.00-00000, arihant, southco, darshana.

Read more
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Read more
Disconnecting and earthing device, 8 pole, 2 way, without off, on load 125 amps at 1000v ac, 2no+2nc and with heavy handle and pad locking arrangement in one position, mounted in a stainless steel enclosure, suitable for ac 23 duty and conforming to iec60947 maximum depth including handle 480mm suitable for switch board cabinet of lhb ac coach as per rdso letter no. el/7.1.108/mssbc dated 17.09.2021 & rdso letter no. el/6.8.21/tl-ac committee dated 11.05.2023 and rdso specification no. rdso/pe

Disconnecting and earthing device, 8 pole, 2 way, without off, on load 125 amps at 1000v ac, 2no+2nc and with heavy handle and pad locking arrangement in one position, mounted in a stainless steel enclosure, suitable for ac 23 duty and conforming to iec60947 maximum depth including handle 480mm suitable for switch board cabinet of lhb ac coach as per rdso letter no. el/7.1.108/mssbc dated 17.09.2021 & rdso letter no. el/6.8.21/tl-ac committee dated 11.05.2023 and rdso specification no. rdso/pe

Read more
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].

Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].

Read more
High voltage hrc fuse of 125 amps, 1000 v ac, breaking capacity 80 ka, type nh1l as per rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dated 17.09.2021 or latest, to siba cat. no. 2028003.125, eaton bussman cat. no. 125nh1lir-1000, eti cat. no. 4182495, efen, ferraz and siemens makes only acceptable. note: regular authorized dealers shall submit authorization letter from oems along with the offer.

High voltage hrc fuse of 125 amps, 1000 v ac, breaking capacity 80 ka, type nh1l as per rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dated 17.09.2021 or latest, to siba cat. no. 2028003.125, eaton bussman cat. no. 125nh1lir-1000, eti cat. no. 4182495, efen, ferraz and siemens makes only acceptable. note: regular authorized dealers shall submit authorization letter from oems along with the offer.

Read more
Dc to dc converter for switch board cabinet of lhb ac coaches-110/24 v, 240w,10a. as per rdso letter no.( update on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoenix-trio-ps-2g/1ac/24dc/10-2903149 only. on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoe

Dc to dc converter for switch board cabinet of lhb ac coaches-110/24 v, 240w,10a. as per rdso letter no.( update on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoenix-trio-ps-2g/1ac/24dc/10-2903149 only. on common bom) el/7.1.108/mssbc dt.17/09/2021 make-m/s.abb part no cp-c.1.24/10/m/s.cosel-klea240f240f-24/m/s.ask powertech-ask-cs-24v,10a/m/s.siemens-6ep13363ba10/m/s.phoe

Read more
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2

Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise