Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Multifunction Meter, Nominal Input Voltage On Site Programmable : 100 To 600 Vl L, Nominal Input Current On Site Programmable : 1/5 A, Higher Auxiliary Supply Range : 100 To 550 V Av/Dc (230 V Ac/Dc Nominal), Lower Auxiliary Supply Range : 12 To 60 V Av/Dc (24 V Ac/48 V Dc Nominal), Accuracy Class : 0.5 S Iec Standard 62053 22, With Rs485 With 2 Relay Modbus For Communication, Impulse Led : For Energy Testing, Ip 20 & Ip 54, With Lcd Display, 3 Phase 3 W/4 W Network, Parameters : Vaf Kw K V Ar
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106445135 |
|
Reference Number |
07245318 |
| Tender Fee | 0 |
| EMD | 4270 |
| Tender Value | - |
| Place | Varanasi |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092024/106445135/viewNitPdf_4704819.pdf |
| Start Date | September 05, 2024 17:27 |
| End Date |
Expired
27/09/2024
Expired 749 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Read moreProgrammable dc power supply (0-400 v, power- 15kw)
Programmable dc power supply (0-400 v, power- 15kw)
Read moreDc power supply source input 230 v ac, 50 hz, output 24 vdc, 68 vdc and 72 vdc, 10 amp, on/off switch and fuse with over voltage, overload and short circuit protection.
Dc power supply source input 230 v ac, 50 hz, output 24 vdc, 68 vdc and 72 vdc, 10 amp, on/off switch and fuse with over voltage, overload and short circuit protection.
Read moreContactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read moreCircuit breaker dc supply, rating 10 a,250 v dc,1 pole with auxiliary contacts as per clw spec. no. clw/es/3/0037 alt. i or latest and abb doc. no. hbtb585555r1023 or latest. note:- latest alteration/specification will be applicable at the time of tender closing.
Circuit breaker dc supply, rating 10 a,250 v dc,1 pole with auxiliary contacts as per clw spec. no. clw/es/3/0037 alt. i or latest and abb doc. no. hbtb585555r1023 or latest. note:- latest alteration/specification will be applicable at the time of tender closing.
Read moreCurrent transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Current transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreEngineering, supply, erection, testing and commissioning of 33 kv power distribution, traction substation, auxiliary substations and 750 v dc third rail traction system for 4 underground metro stations from mominpur (excl.)-esplanade including tunnels and iim station including viaduct from joka (excl.)-iim section of diamond park-joka-esplanade corridor of metro railway, kolkata (west bengal), india
Engineering, supply, erection, testing and commissioning of 33 kv power distribution, traction substation, auxiliary substations and 750 v dc third rail traction system for 4 underground metro stations from mominpur (excl.)-esplanade including tunnels and iim station including viaduct from joka (excl.)-iim section of diamond park-joka-esplanade corridor of metro railway, kolkata (west bengal), india
Read moreof your Industry type