Particulars | Details |
---|---|
Title |
Motor Protection Circuit Breaket (Mpcb) Of Rated Current 1 1.6 Amp With 2 Nos Aux Contacts (1 No1 Nc Aux Contact Block), Thermal Range 1 1.6 Amp, Class 10, Breaking Capacity 50 Ka, 3 Pole, Rated Voltage 690 Vac, Confirming To Rdso Modification Sheet No. Rdso/Pe/Ms/Tl/0090 2023 (Rev 0). Rdso Approved Make & Cat No.: Abb Cat No. Ms116 1.6, Hk1 11, Schneider Cat No. Gv2 Me06 Gv Ae11, Siemens Cat No. 3 Rv20111 Aa103 Rv2901 1 E, And L&T Cat No. St418940000 St419450000.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106547076 |
Reference Number |
40241594 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Jaipur |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/022025/106547076/viewNitPdf_4798287.pdf |
Start Date | December 07, 2024 15:27 |
End Date |
26/02/2025 ( Expired 95 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Power contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender
Read moreMotor protection circuit breaket (mpcb) of rated current 1-1.6 amp with 2 nos aux contacts (1no1nc aux contact block), thermal range 1-1.6 amp, class-10, breaking capacity-50ka, 3pole, rated voltage 690vac, confirming to rdso modification sheet no. rdso/pe/ms/tl/0090-2023 (rev-0). rdso approved make & cat no.:- abb cat no. ms116-1.6, hk1-11, schneider cat no. gv2-me06gv-ae11, siemens cat no. 3rv20111aa103rv2901-1e, and l&t cat no. st418940000st419450000.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) 2.5 - 4 a, class 10, breaking capacity 50ka, pole 3p, rated voltage 415v ac, 1 no 1 nc auxilary contact block confirming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0).
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read more3-pole mcb, rated current: 16a, curve: d , voltage 415v ac, breaking capacity: 10 ka of make: l&t of model no. bb30160d or siemens of model no. 5sl73168rc or abb of model no. sb203 m-d16 or schneider of model no. a9n3p16d or legrand of model no. 408762. conforming bom of rdso specification no. rdso/pe/spec/ac/0192-2018 (rev.1)
For complete deion and other details, please refer to tender
Read moreMain mcb 16 amps, 3pole to intec part no.icac-074 for roof mounted air conditioning system of cab ac as per rdso specification no. rdso/2007/el/spec/0055 rev. 2. make : l&t/abb/siemens/schneider/legrand. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram/fedders lylord/sidwal/kki fitted in electric loco.
For complete deion and other details, please refer to tender
Read moreMpcb 1.0 to 1.6 amp to intec part no. icac-101 for roof mounted air conditioning system of cab ac as per rdso specification no. rdso/2007/el/spec/0055 rev. 2. make l & t/abb/siemens/schneider/legrand. note:- (1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram/fedders lylord/sidwal/kki fitted in electric loco.
For complete deion and other details, please refer to tender
Read moreFeeder selection rotary switch (s02) with making i-0-ii net 1- local main supply- net 2. (change over switch with 0- position 3 pole, rated voltage 690 v ac, rated current 16 amps, siemens model.no. 3sb5000-2db013sb5400-0a, l&t model. no. 61069scb03tdy, schneider model no.xb5ad33nzbe101nzbe102n,abb model. no m3ss1- 10vmcbh-00mcb-10 only acceptable for lhb ac switch board cabinet as per rdso spec no. rdso/pe/spec/0184-2015 rev 1 or latest. material shall be procured from said oem or his
For complete deion and other details, please refer to tender
Read moreMcb for heater unit with auxillary contact block having ratings: 3 pole, 415v ac, rated current 16 amps, c-curve, breaking capacity 10ka as per sn-36 of bom for switch board cabinet unit having rdso s specification no. rdso/pe/spec/0184-2015(rev-1). make: abb/schneider/l&t/siemens/eaton. note: oem or their authorized dealers with tender specific authorization letters from oem only to quote with documentary evidence
For complete deion and other details, please refer to tender
Read moreK44 contactor for 60kva transformer rate [k44 contactor for 60kva transformer rated current: 200a, rated voltage:690v ac, main pole:4, aux contact :01no1nc, control voltage:230v ac (168 v ac-300 v ac means 230v ac /- 30 percent ) with surge suppressor as per item no.k01 of bill of material of rdso spec no. rdso/pe/spec/d/0184-2015 (rev.1) suitable for lhb type ac coaches switch board cabinet. brands: l&t/siemens/schneider/abb only. 1) the firm should submit authorized dealership certificate