| Particulars | Details |
|---|---|
| Title |
Motor Protection Circuit Breaker (Mpcb) Of Rated Current 1 1.6 Amp With 2 Nos Aux Contacts (1 No1 Nc Aux Contact Block), Thermal Range 1 1.6 Amp, Class 10, Breaking Capacity 50 Ka, 3 Pole, Rated Voltage 690 V Ac, Conforming To Rdso Modification Sheet No. Rdso/Pe/Ms/Tl/0090 2023 (Rev 0) And Rdso Specification No. Rdso/Pe/Spec/Ac/0192 2018 (Rev 1).
As Per Rdso Approved Make & Cat No. : Abb Cat No. Ms116 1.6, Hk1 11, Schneider Cat No. Gv2 Me06 Gv Ae11, Siemens Cat No. 3 Rv20111 Aa103 Rv2901 1 E, And
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106793810 |
|
Reference Number |
40251594 |
| Tender Fee | 0 |
| EMD | 30790 |
| Tender Value | - |
| Place | Jaipur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092025/106793810/viewNitPdf_5077246.pdf |
| Start Date | August 13, 2025 16:43 |
| End Date |
Expired
16/09/2025
Expired 395 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)
Read moreTerminal board assembly common for 25 kw/4.5 kw alternator as per rdso drg. no. rdso/pe/sk/ac/0047-2003 (rev-4), conforming to rdso specification no. rdso/pe/spec/ac/0056-2014 (rev-1).
Terminal board assembly common for 25 kw/4.5 kw alternator as per rdso drg. no. rdso/pe/sk/ac/0047-2003 (rev-4), conforming to rdso specification no. rdso/pe/spec/ac/0056-2014 (rev-1).
Read moreSet of return & fresh air filter(4 nos. return air filter and 4 nos. fresh air filter ) for lhb type ac coaches, conforming to rdso spec. no. rdso/pe/spec/ac/0055-2003 (rev.2) with drg no. rdso/pe/sk/ac/0073-2004 (rev-1) and rdso/pe/sk/ac/0074-2004,(rev-1) or latest.
Set of return & fresh air filter(4 nos. return air filter and 4 nos. fresh air filter ) for lhb type ac coaches, conforming to rdso spec. no. rdso/pe/spec/ac/0055-2003 (rev.2) with drg no. rdso/pe/sk/ac/0073-2004 (rev-1) and rdso/pe/sk/ac/0074-2004,(rev-1) or latest.
Read moreProcurement of 110v brushless dc/ac universal fan 450mm sweep as per rdso specification no. rdso/pe/spec/tl/0021/2005 rev-3(amd-1) & rdso specification no. rdso/pe/spec/tl/0050 (rev-1) with ss guard, rubber gasket, connector & hardware included.
Procurement of 110v brushless dc/ac universal fan 450mm sweep as per rdso specification no. rdso/pe/spec/tl/0021/2005 rev-3(amd-1) & rdso specification no. rdso/pe/spec/tl/0050 (rev-1) with ss guard, rubber gasket, connector & hardware included.
Read moreDry type fresh air filter (type-1), size-495x260x12.5mm suitable for lhb variant ac coaches, conforming to rdso specn. no. rdso/pe/spec/ ac/0055-2003 (rev.3) and drg. no. rdso/pe/sk/ac/0074-2004 (rev. 1)
Dry type fresh air filter (type-1), size-495x260x12.5mm suitable for lhb variant ac coaches, conforming to rdso specn. no. rdso/pe/spec/ ac/0055-2003 (rev.3) and drg. no. rdso/pe/sk/ac/0074-2004 (rev. 1)
Read morePower contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreMpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Read moreContactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Read moreof your Industry type