Tender Details

Particulars Details
Title
Motor Protection Circuit Breaket (Mpcb) Of Rated Current 1 1.6 Amp, With 2 Nos. Aux Contacts (1 No1 Nc Aux
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106238191
Reference
Number
40231594
Tender Fee 0
EMD 0
Tender Value -
Place Jaipur
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/012024/106238191/viewNitPdf_4447454.pdf

Start Date January 07, 2024 14:40
End Date
Expired 17/01/2024

Expired 1003 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Ac line reactor 2.5 mh 3phase 415v 50hz rated current 9.5amp peak current 18amp,ac line reactor 0.8mh rated current 37 amp peak current 75 amp,a,b,c

Ac line reactor 2.5 mh 3phase 415v 50hz rated current 9.5amp peak current 18amp,ac line reactor 0.8mh rated current 37 amp peak current 75 amp,a,b,c

Read more
Earth leakage circuit breaker (elcb) current rating 25 amp etc.

Earth leakage circuit breaker (elcb) current rating 25 amp etc.

Read more
Motor protection circuit breaker (mpcb),residual current operated circuit breakers (rccb) without integral overcurrent protection isi marked to is 12640 (part 1)

Motor protection circuit breaker (mpcb),residual current operated circuit breakers (rccb) without integral overcurrent protection isi marked to is 12640 (part 1)

Read more
3 pole vacuum contactor, rated current 630 amp, size- s14 part no-3tf6844-0cq7, make-seimens

3 pole vacuum contactor, rated current 630 amp, size- s14 part no-3tf6844-0cq7, make-seimens

Read more
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Read more
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).

Read more
Miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),mcb, 2p with 2pp 25a, type-b, rated sc current-10ka,mbcb, 2p with 2pp 32a, type-b, rated sc current-10ka

Miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),mcb, 2p with 2pp 25a, type-b, rated sc current-10ka,mbcb, 2p with 2pp 32a, type-b, rated sc current-10ka

Read more
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.

Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.

Read more
Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.

Motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3 pole type gv2p14 of schneider or abb with aux. contact block 2 no (normally open) as per clw specn.no.clw/es/3/0096 alt.l or latest, str no. clw/2021/eldo/e/str/0104 rev.0 or latest.

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Click Here to Download Dockets
of your Industry type