Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Mtps I Bm Unit Iv Rotating Parts Removal Of Deteriorated And Peeled Off Insulation And Renewal With New Insulation Materials In Id Fans 4 A And 4 B Outlet Vertical Duct Chimney Horizontal Duct Id Fan A And B Inlet Common Duct Header Top Front And Rear
|
| Description |
Mtps I Bm Unit Iv Rotating Parts Removal Of Deteriorated And Peeled Off Insulation And Renewal With New Insulation Materials In Id Fans 4 A And 4 B Outlet Vertical Duct Chimney Horizontal Duct Id Fan A And B Inlet Common Duct Header Top Front And Rear
|
| Organisation | TNEB Limited | State Govt. and UT |
| Tender Id | 2024_EB_461310_1 |
|
Reference Number |
CE/MTPS-I/SE/M-I/BM/ OT.68 / 2024-25. |
| Tender Fee | 0 |
| EMD | 18100 |
| Tender Value | - |
| Place | Mettur Thermal Power Station-I / Mettur Dam |
| Link |
View Original Tender Notice
https://tntenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=548254 |
| Start Date | July 08, 2024 23:00 |
| End Date |
Expired
22/07/2024
Expired 771 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Mtps i bm unit iv rotating parts removal of deteriorated and peeled off insulation and renewal with new insulation materials on esp outlet to id fan inlet common duct bottom sides id fan 4a 4b casing and other related works
Mtps i bm unit iv rotating parts removal of deteriorated and peeled off insulation and renewal with new insulation materials on esp outlet to id fan inlet common duct bottom sides id fan 4a 4b casing and other related works
Read moreMtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in id fan 1b outlet fg duct horizontal vertical portion and id fans outlet to chimney common fg duct area etc
Mtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in id fan 1b outlet fg duct horizontal vertical portion and id fans outlet to chimney common fg duct area etc
Read moreMtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new same insulation materials on the portion in fg duct chimney area and id fan casing area and other related works
Mtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new same insulation materials on the portion in fg duct chimney area and id fan casing area and other related works
Read moreReplacement of deteriorated ahu duct insulation
Replacement of deteriorated ahu duct insulation&#x0d and damaged false ceiling at hbt trauma care&#x0d hospital
Read moreMtps i bm unit ii removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in esp outlet common fg duct area id fan 2b outlet fg duct horizontal vertical portion and id fans casing area etc
Mtps i bm unit ii removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in esp outlet common fg duct area id fan 2b outlet fg duct horizontal vertical portion and id fans casing area etc
Read moreMtps i bm unit i removal of deteriorated and dislodged insulation and re insulation on the portion of id fan 1a outlet and portion of horizontal duct side portion for id fans outlet to chimney and other related works
Mtps i bm unit i removal of deteriorated and dislodged insulation and re insulation on the portion of id fan 1a outlet and portion of horizontal duct side portion for id fans outlet to chimney and other related works
Read moreTtps es em iii prive maintenance repairing and painting of ht motors of id fan motor 4a 4b fd fan motor 4a 4b pa fan motor 4a 4b and coal mill motor 4a 4b 4c 4d 4e 4f during annual statutory overhauling of unit iv for year 2025 26 or thereafter
Ttps es em iii prive maintenance repairing and painting of ht motors of id fan motor 4a 4b fd fan motor 4a 4b pa fan motor 4a 4b and coal mill motor 4a 4b 4c 4d 4e 4f during annual statutory overhauling of unit iv for year 2025 26 or thereafter
Read moreMtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in id fan 1a and 1b casing portion and other related works
Mtps i bm unit i removal of deteriorated and peeled off insulation and re insulation with new insulation materials on the portion in id fan 1a and 1b casing portion and other related works
Read moreTtps es em iii replacing the existing wornout m s roof by a new sheet in id fan motor 4a and 4b pa fan motor 4a fd fan motor 4a and 4b in unit 4 boiler area
Ttps es em iii replacing the existing wornout m s roof by a new sheet in id fan motor 4a and 4b pa fan motor 4a fd fan motor 4a and 4b in unit 4 boiler area
Read moreof your Industry type