Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
69167 Needle For Inside Out Meniscal Repair With Eye For Thread.1. Standard Length Stainless Steel With A 38cm Or More In Length And Diameter Should Be 0.8 Mm Or Less. 2. Should Be Made Up Of High Strength, Flexible Stainless Steel, 3. Needle Should Have Eye On Non Sharp End To Pass Minimum 2 0 Suture. 4. Needles Can Be Used With Other Meniscal Repair Systems..
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 73929013 |
|
Reference Number |
H1245094 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Mumbai CST |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/062024/106380274/viewNitPdf_4612971.pdf |
| Start Date | June 20, 2024 18:46 |
| End Date |
Expired
28/06/2024
Expired 842 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Read moreThe nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read more1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
Read moreChlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be
Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be
Read moreDisposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Read morePacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Read morePolyester double layered heavy duty duplex webbing sling reinforced eye at both end (loop) capacity - 2ton, length - 3 meters, having anti abrasive sleeve 0.5 meter long against protection from rough surface as per is:15041-2025. (note - sling should be tested by govt. approved laboratory. certificate to be provided at the time of supply. all sling should have individual metal tag on which mfg year and serial number must be punch
Polyester double layered heavy duty duplex webbing sling reinforced eye at both end (loop) capacity - 2ton, length - 3 meters, having anti abrasive sleeve 0.5 meter long against protection from rough surface as per is:15041-2025. (note - sling should be tested by govt. approved laboratory. certificate to be provided at the time of supply. all sling should have individual metal tag on which mfg year and serial number must be punch
Read moreArterial venous fistula needle of size 17g x 1 back eye and clamp .needle made of stainless steel with beveled back eye , kink resistant medical grade pvc tubing with color coded fixed or rotating wings, arterial venous fistula needle size:16g x 1 . needle made of stainless steel with beveled back eye and clamp and kink resistant medical grade pvc tubing with color coded fixed or rotating wings.
Arterial venous fistula needle of size 17g x 1 back eye and clamp .needle made of stainless steel with beveled back eye , kink resistant medical grade pvc tubing with color coded fixed or rotating wings, arterial venous fistula needle size:16g x 1 . needle made of stainless steel with beveled back eye and clamp and kink resistant medical grade pvc tubing with color coded fixed or rotating wings.
Read moreReducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Reducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Read morePvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Pvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Read moreof your Industry type