Needle For Inside Out Meniscal Repair With Eye For Thread.1. Standard Length Stainless Steel With A 38cm Or More In Length And Diameter Should Be 0.8 Mm Or Less. 2. Should Be Made Up Of High Strength, Flexible Stainless Steel, 3. Needle Should Have Eye On Non Sharp End To Pass Minimum 2 0 Suture. 4. Needles Can Be Used With Other Meniscal Repair Systems.
(As Per Detailed Specifications Attached)
|
| Description |
Needle For Inside Out Meniscal Repair With Eye For Thread.1. Standard Length Stainless Steel With A 38cm Or More In Length And Diameter Should Be 0.8 Mm Or Less. 2. Should Be Made Up Of High Strength, Flexible Stainless Steel, 3. Needle Should Have Eye On Non Sharp End To Pass Minimum 2 0 Suture. 4. Needles Can Be Used With Other Meniscal Repair Systems.
(As Per Detailed Specifications Attached)
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 05, 2026 21:28 |
| End Date |
Open
19/10/2026
4 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read more1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
Read morePacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Read moreDisposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe
Read moreArterial venous fistula needle of size 17g x 1 back eye and clamp .needle made of stainless steel with beveled back eye , kink resistant medical grade pvc tubing with color coded fixed or rotating wings, arterial venous fistula needle size:16g x 1 . needle made of stainless steel with beveled back eye and clamp and kink resistant medical grade pvc tubing with color coded fixed or rotating wings.
Arterial venous fistula needle of size 17g x 1 back eye and clamp .needle made of stainless steel with beveled back eye , kink resistant medical grade pvc tubing with color coded fixed or rotating wings, arterial venous fistula needle size:16g x 1 . needle made of stainless steel with beveled back eye and clamp and kink resistant medical grade pvc tubing with color coded fixed or rotating wings.
Read moreReducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Reducing nipple of size 1/2 x 3/8 bsp threading (parallel) on both sides, total length - 40mm; 1/2 threaded length -15 mm; 3/8 threaded length-15mm, hex. head thickness-10mm, width af27mm, 3/8 ends inside should have tapered profile (cone type). material: carbon steel astm-a108 & grade a1018 with zinc coated. note: material should be machined from forged planks & not to be casted.
Read morePvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Pvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Read moreEndoscopic ultrasound transmural drainage device consists of 1) device should have a size of 6fr in diameter and working length of minimum 180cm. 2). should have a diathermy tip at the distal end combined with port for injecting contrast compatible with 0.035 inch guide wire.
Endoscopic ultrasound transmural drainage device consists of 1) device should have a size of 6fr in diameter and working length of minimum 180cm. 2). should have a diathermy tip at the distal end combined with port for injecting contrast compatible with 0.035 inch guide wire.
Read more1) hemoclip rotatable should be a) pre-loaded ready to use b) multiple times reopening capability c) wide jaw span greater than and equal to 16mm d) length 150 to 200cm and 360 degree rotation and 1:1 movement, 2) injection gold probe consists of : a) 7fr injection gold probe combined with sclerotherapy needle and firm catheter shaft b) should have separate irrigation channel, compatible with a 2.8mm working channel c) working length more than 160cm and have a ceramic and gold tip, 3) hemospra
1) hemoclip rotatable should be a) pre-loaded ready to use b) multiple times reopening capability c) wide jaw span greater than and equal to 16mm d) length 150 to 200cm and 360 degree rotation and 1:1 movement, 2) injection gold probe consists of : a) 7fr injection gold probe combined with sclerotherapy needle and firm catheter shaft b) should have separate irrigation channel, compatible with a 2.8mm working channel c) working length more than 160cm and have a ceramic and gold tip, 3) hemospra
Read moreOne piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.