Tender Details
Particulars | Details |
---|---|
Title |
Departmental Estimate For Oil Leakage Repairing And Maintenance 33 Kv Current Transformer(one Set) 200/1 1 1 Controlling C.T Tr No 1, Tr No.2 Andtr No.4 At Ramkanali Sub Station Katras Area Iv. (B) Cum Job Details For Repairing And Overhauling Of
|
Description |
Departmental Estimate For Oil Leakage Repairing And Maintenance 33 Kv Current Transformer(one Set) 200/1 1 1 Controlling C.T Tr No 1, Tr No.2 Andtr No.4 At Ramkanali Sub Station Katras Area Iv. (B) Cum Job Details For Repairing And Overhauling Of
|
Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
Tender Id | 2024_BCCL_317931_1 |
Reference Number |
BCCL/KA/IV/ENM/E-TEN/24-25/145 DT.20.9.2024 |
Tender Fee | 0 |
EMD | 2808 |
Tender Value | |
Place | R.K SUB STATION KATRAS AREA |
Link | https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=329532 |
Start Date | September 21, 2024 14:30 |
End Date |
05/10/2024 ( Expired 236 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Repairing and reconditioning of a. 11 kv 800amp, prabhu make sl no 0526 vcb switch of feeder 1 and b 3.3 kv, 400amp ocb crompton greaves make sl nokugp.ocb.ccl001 used for primary control of lighting transformer 630 kva 3.3kv 440v installed at main s
Repairing and reconditioning of a. 11 kv 800amp, prabhu make sl no 0526 vcb switch of feeder 1 and b 3.3 kv, 400amp ocb crompton greaves make sl nokugp.ocb.ccl001 used for primary control of lighting transformer 630 kva 3.3kv 440v installed at main s
Read moreWork no. 1 - repairing and upgradation of 33 kv (33000volt) switchyard and repairing of 2500kva (33000/3300volt) transformer at shinganapur raw water pumping station.
Work no. 1 - repairing and upgradation of 33 kv (33000volt) switchyard and repairing of 2500kva (33000/3300volt) transformer at shinganapur raw water pumping station.
Read moreEstimate for providing of 6 no mid span 200 kg ,1 no 280k, 1 no rsj pole 11 mtr for lt line and 3 no 200 kg for 11 kv , 1 no 11 mtr hbeam for 33 kv line, at (11 kv sadar and 33 kv tikari fdr ) in betul town 2 dc o and m division betul-south
Estimate for providing of 6 no mid span 200 kg ,1 no 280k, 1 no rsj pole 11 mtr for lt line and 3 no 200 kg for 11 kv , 1 no 11 mtr hbeam for 33 kv line, at (11 kv sadar and 33 kv tikari fdr ) in betul town 2 dc o and m division betul-south
Read moreEstimate for replacement of 1 no. 5 mva failed power transformer at 33/11 kv jamthi s/s in padhar dc under (o and m) dn. betul-south in betul circle
Estimate for replacement of 1 no. 5 mva failed power transformer at 33/11 kv jamthi s/s in padhar dc under (o and m) dn. betul-south in betul circle
Read moreConstruction of senior resident housing in govt medical college at patiala punjab pole mounted sub station 1 no transformer 200 kva for block a and c 1 no transformer 315 kva for block b
Construction of senior resident housing in govt medical college at patiala punjab pole mounted sub station 1 no transformer 200 kva for block a and c 1 no transformer 315 kva for block b
Read moreProviding and fixing of material for repair work, oil filteration and oil top-up of 2 no. 315 kva transformer of 33 kv sub-station at man project, jeerabad distt. dhar (m.p.)
Providing and fixing of material for repair work, oil filteration and oil top-up of 2 no. 315 kva transformer of 33 kv sub-station at man project, jeerabad distt. dhar (m.p.)
Read more1. complete repairing of 200-amps, 550v, abc make acb switch at 10l/13d main for sdl m/c no.-1137 of mithani colliery under sodepur area. 2.repairing of 400-amps, 550v, oil circuit breaker (switch) r/b make of mit
1. complete repairing of 200-amps, 550v, abc make acb switch at 10l/13d main for sdl m/c no.-1137 of mithani colliery under sodepur area. 2.repairing of 400-amps, 550v, oil circuit breaker (switch) r/b make of mit
Read more(1) shifting/dismantling /repairing and changing of 440 volt over head line from 4 no.sub-station to chhat talab of akwmc,under katras area.(2) dismantling and erection of 3.3 kv over head line in ocp for shifting of o/b dumping area at akwmc.
(1) shifting/dismantling /repairing and changing of 440 volt over head line from 4 no.sub-station to chhat talab of akwmc,under katras area.(2) dismantling and erection of 3.3 kv over head line in ocp for shifting of o/b dumping area at akwmc.
Read moreComplete repairing of 800amp 3.3kv ocb with busbar gec make sl. no 40/0560 for secondary controlling of 1 mva 11kv / 3.3 kv transformer at 07 no transformer of abdkc.
Complete repairing of 800amp 3.3kv ocb with busbar gec make sl. no 40/0560 for secondary controlling of 1 mva 11kv / 3.3 kv transformer at 07 no transformer of abdkc.
Read moreAdministrative approval for complete repairing of 6.6 kv /1000 amps vcb switch with bus bar sl no- 19/31/01 make opg at ramkanali sub station under katras area.
Administrative approval 
 for complete repairing of 
 6.6 
 kv /1000 amps vcb 
 switch with bus bar sl no- 
 19/31/01 make opg at 
 ramkanali sub station 
 under katras area.