Results for: Used Transformer Oil
Find the latest Used Transformer Oil tenders from different organizations. SigmaTenders helps you participate in these online e-Procurement tenders. We provide access to tender details, BOQs, and technical bids, along with bidding support for Used Transformer Oil e-tenders. Get matching tenders on WhatsApp, with coverage across government websites, GeM and e-Procurement portals.
A)cork sheet bushing oil leakage stopping of 500kva,11kv/440v transformer, sl.no.800/30, ngef make at madhuban dg b)200kva,11kv/550v transformer used for birajpur c)providing and fitting of 630a mccb, 04pole for controlling of birajpur s/s at ampc.
A)cork sheet bushing oil leakage stopping of 500kva,11kv/440v transformer, sl.no.800/30, ngef make at madhuban dg b)200kva,11kv/550v transformer used for birajpur c)providing and fitting of 630a mccb, 04pole for controlling of birajpur s/s at ampc.
Reclamation of old and used dirty transformer oil with help of required/ desired chemicals and as per is 1866/2000 with latest amendment at bijnor, gajraula and moradabad c.t.r workshop under electricity workshop division, moradabad.
Reclamation of old and used dirty transformer oil with help of required/ desired chemicals and as per is 1866/2000 with latest amendment at bijnor, gajraula and moradabad c.t.r workshop under electricity workshop division, moradabad.
Transformer oil pump suitable and compatible with jstr make transformer (2556 kva) used in vande bharat train set: a) model: cil30/jst or 1530/jst, b) size: 80 x 80 mm, c) discharge : 833lpm, d) head:1.2 bar,e)motor: 3ph,50 hz, 415 v ac 4 hp/3.0 kw, amps:7.0, f) speed: 2850rpm, g) class of insulation: h, make: flow oil or flow tech or similar..
For complete deion and other details, please refer to tender
Transformer oil pump suitable and compatible with jstr make transformer (2556kva) used in vande bharat train set: a) model: cil30/jst or 1530/jst, b) size: 80 x 80 mm, c) discharge : 833lpm, d) head:1.2 bar, e)motor: 3ph,50hz,400vac 4 hp/3.0 kw, amps:7.0, f) speed: 2850rpm, g) class of insulation: h,
For complete description and other details, please refer to tender document.
Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Supply testing aand commissioning of 33kv outdoor power transformer vcb rmg
Supply, testing and commissioning of outdoor oil cooled distribution transformer vacuum circuit breaker vcb and ring main gear panels for avadi perambur and k.k nagar e-bus depot uses
Supply, testing and commissioning of two [supply, testing and commissioning of two phase primary current injection test kit , air/oil cooled ( transformer air cooled section and dimmerstat (variac) in oil cooled section ), input : 415 v , ac , 2ph, 50hz output: 0-25v at range of 0 to 5000amps with minimum resolution 1 amperes suitable for indoor use in maximum ambient temperature of 50 degree centigrade. above unit shall complete with 1.dimmerstat, dw transformer, output ammeter with ct and tr
For complete deion and other details, please refer to tender
Transformer oil pump set with 3-phase induction motor for use on 25 kv single phase, 50 hz electric locomotive. motor as per rdso specn. no. e/10/03/08 revised sept. 1995 with amendment no. 1 & 2 and pump as per clw specn. no. clw/es/o-1alt-l or latest.
For complete deion and other details, please refer to tender
🚂 Procurement Opportunity: Transformer Oil Pump Set 🔧 The Ministry of Railways, Central Government, invites bids for the supply of a Transformer Oil Pump Set with a 3-Phase Induction Motor for use on 25 KV Single Phase, 50 Hz Electric Locomotive. The specifications are as per RDSO Specification No. E/10/03/08 revised in September 1995, with amendments No. 1 & 2, and the pump set as per CLW Specification No. CLW/ES/O-1ALT-L or the latest version. 📅 Bid Submission Deadline: June 4, 2024, 11:00 AM The tender fee is INR 0, with an Earnest Money Deposit (EMD) of INR 34,100. Interested bidders should refer to the tender document for complete details and submission guidelines. Keywords: Transformer Oil Pump Set, 3-Phase Induction Motor, Electric Locomotive, RDSO Specification, CLW Specification, Ministry of Railways, Government Tender, Procurement
Supply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Supply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Se/gts/ot-24/25-26
Procurement of new transformer oil for use in gas turbine power stations
Get new Used Transformer Oil tenders
Tell us what you supply or do. We'll send you matching tenders on WhatsApp and call you about them.
Free tender checklists for your industry →Can't meet a tender's eligibility alone? Find a JV or local partner →
Need help bidding on these tenders?
Our team helps with GeM registration, eligibility, tender documents, compliance and bid submission.
Get bid support