Tender Details
Particulars | Details |
---|---|
Title |
Supply, Testing And Commissioning Of Two [Supply, Testing And Commissioning Of Two Phase Primary Current Injection Test Kit , Air/Oil Cooled ( Transformer Air Cooled Section And Dimmerstat (Variac) In Oil Cooled Section ), Input : 415 V , Ac , 2 Ph, 50 Hz Output: 0 25 V At Range Of 0 To 5000 Amps With Minimum Resolution 1 Amperes Suitable For Indoor Use In Maximum Ambient Temperature Of 50 Degree Centigrade. Above Unit Shall Complete With 1.Dimmerstat, Dw Transformer, Output Ammeter With Ct And Tr
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106543861 |
Reference Number |
L2246389 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Hubli |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/012025/106543861/viewNitPdf_4794697.pdf |
Start Date | December 04, 2024 17:28 |
End Date |
06/01/2025 ( Expired 105 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Similar Tenders
Supply, testing and commissioning of two [supply, testing and commissioning of two phase primary current injection test kit , air/oil cooled ( transformer air cooled section and dimmerstat (variac) in oil cooled section ), input : 415 v , ac , 2ph, 50hz output: 0-25v at range of 0 to 5000amps with minimum resolution 1 amperes suitable for indoor use in maximum ambient temperature of 50 degree centigrade. above unit shall complete with 1.dimmerstat, dw transformer, output ammeter with ct and tr
For complete deion and other details, please refer to tender
Read moreSupply installation and commissioning of motorised bdv oil test set designed to deliver output voltage 0-100 kv 1kva, suitable for working on 220/230v single phase ac supply. the unit shall be designed and housed in ms/ss sheet housing finely finished powdered coated painting to test the transformer oil of electric locomotive as per rdso specification : rdso/elrs/smi/158 & is 6792 or latest . the unit must contain test chamber in protectve cover with test cup set containg electrodes , magnet
For complete deion and other details, please refer to tender
Read moreSupplying, installation , testing and commissioning of 1250 kva 11.433 50hz 3 phase copper wound,oil cooled distribution transformer with oltc , avr and rtcc panel as per is 1180 , eel 1 including laying xlpe armored cable 3 core 11 kv existing ess
Supplying, installation , testing and commissioning of 1250 kva 11.433 50hz 3 phase copper wound,oil cooled distribution transformer with oltc , avr and rtcc panel as per is 1180 , eel 1 including laying xlpe armored cable 3 core 11 kv existing ess
Read more
Click
Here to Download Dockets
of your Industry type
of your Industry type