Limit Switch Suitable For 11 Kv Make Bhel 70 No Limit Switch Suitable For 11 K.V. Make Crompton 70 No Limit Switch Suitable For 11 K.V. Make Stelmec 60 No.
|
| Description |
Limit Switch Suitable For 11 Kv Make Bhel 70 No Limit Switch Suitable For 11 K.V. Make Crompton 70 No Limit Switch Suitable For 11 K.V. Make Stelmec 60 No.
|
| Organisation | Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited | State Govt. and UT |
| Tender Id | 2024_MKVVC_383351_1 |
|
Reference Number |
GM/ONM/datia/Pur/23-24/3042 Dated 19.11.24 |
| Tender Fee | 885 |
| EMD | 3000 |
| Tender Value | - |
| Place | Datia |
| Link |
View Original Tender Notice
https://mptenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=451411 |
| Start Date | November 20, 2024 23:30 |
| End Date |
Expired
26/11/2024
Expired 691 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Mini limit switch 110 v dc, 0.4a, 1 no + nc adjustable 30 mm to 70 mm with fittings (nut bolt & washer).
Mini limit switch 110 v dc, 0.4a, 1 no + nc adjustable 30 mm to 70 mm with fittings (nut bolt & washer).
Read moreSpares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Spares suitable for siemens make 420 kv,2000amps,tp 415v motor operated centre break isolator with single earth switch type 400 kv hcb installed at 400 kv switchyard
Read moreTvss (surge protection device) , imax: 70ka imax: 70 ka uc: 275 v- 50-60 hz in: 30 ka up: 1.5 kv abb/,tvss (surge protection device) , imax: 40ka imax: 40 ka uc: 275 v- 50-60 hz in: 20 ka up: 1.4 kv abb/,tvss (surge protection device) , imax: 15ka imax: 15 ka uc: 275 v- 50-60 hz in: 5 ka up: 1 kv abb/ ov
Tvss (surge protection device) , imax: 70ka imax: 70 ka uc: 275 v- 50-60 hz in: 30 ka up: 1.5 kv abb/,tvss (surge protection device) , imax: 40ka imax: 40 ka uc: 275 v- 50-60 hz in: 20 ka up: 1.4 kv abb/,tvss (surge protection device) , imax: 15ka imax: 15 ka uc: 275 v- 50-60 hz in: 5 ka up: 1 kv abb/ ov
Read moreSix finger interlock unit comlete for switch t2 to bhel drg no. 15801430007v01 acs no. 1282 fig ref 000 or beil drg no b158014300070 v01 suitable for fitment in memu motor coach .
Six finger interlock unit comlete for switch t2 to bhel drg no. 15801430007v01 acs no. 1282 fig ref 000 or beil drg no b158014300070 v01 suitable for fitment in memu motor coach .
Read moreFlush type switch 6 amp,flush type switch 16 amp,flush type socket 6 amp,flush type socket 16 amp,3 pin top or plug 16 amp,rectangular 25 mm,cable socket or lugs for cable size of 35 mm copper heavy duty.,cable socket o rlugs for cable size of 50 mm copper heavy duty.,cable socket or lugs for cable size of 70 mm copper heavy duty.,cable socket or lugs for cable size of 95 mm copper heavy duty.,cable socket or lugs for cable size of 120 mm copper heavy duty,pvc insulated 1.1 k.v copper conductor 3 core pvc frls 1.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor 3 core pvc frls 2.5 mm sq. confirming to is 694 latest.,single core pvc frls 1.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 2.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 4.0 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 6.0 mm sq. confirming to is 694 latest.,pvc insulate
Flush type switch 6 amp,flush type switch 16 amp,flush type socket 6 amp,flush type socket 16 amp,3 pin top or plug 16 amp,rectangular 25 mm,cable socket or lugs for cable size of 35 mm copper heavy duty.,cable socket o rlugs for cable size of 50 mm copper heavy duty.,cable socket or lugs for cable size of 70 mm copper heavy duty.,cable socket or lugs for cable size of 95 mm copper heavy duty.,cable socket or lugs for cable size of 120 mm copper heavy duty,pvc insulated 1.1 k.v copper conductor 3 core pvc frls 1.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor 3 core pvc frls 2.5 mm sq. confirming to is 694 latest.,single core pvc frls 1.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 2.5 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 4.0 mm sq. confirming to is 694 latest.,pvc insulated 1.1 k.v copper conductor single core pvc frls 6.0 mm sq. confirming to is 694 latest.,pvc insulate
Read moreHog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Hog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches
Read moreSpring charging motor for 220 kv,motor 230v ac dc type c-22,spring charging motor for 66kv,torsion spring right for 66kv,torsion spring left for 66kv,surface space heater for 66kv,thermostate for 66kv,silica gel breather 250 gram,silica gel breather 500 gram,split type arching horn,one of gasket,630a motorized changeover switch,63a 2pole 2way motorized change over switch,solid copper busbar,lighting arrester disconnector,stainless steel bolt m12x100,stainless steel bolt m12x150,silica gel blue 4 to 6 mm,25 kv drop out fuse,hot air gun,hydrometer,long barreal 70 sqmm copper lug,tie rod insulator operating rod insulator
Spring charging motor for 220 kv,motor 230v ac dc type c-22,spring charging motor for 66kv,torsion spring right for 66kv,torsion spring left for 66kv,surface space heater for 66kv,thermostate for 66kv,silica gel breather 250 gram,silica gel breather 500 gram,split type arching horn,one of gasket,630a motorized changeover switch,63a 2pole 2way motorized change over switch,solid copper busbar,lighting arrester disconnector,stainless steel bolt m12x100,stainless steel bolt m12x150,silica gel blue 4 to 6 mm,25 kv drop out fuse,hot air gun,hydrometer,long barreal 70 sqmm copper lug,tie rod insulator operating rod insulator
Read morePower contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.
Read morePower contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Read moreSupply of limit switch suitable for 11kv make bhel crompton stelmec vcb and slica gel
Supply of limit switch suitable for 11kv make bhel crompton stelmec vcb and slica gel
Read moreof your Industry type