Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Jaipur Divn: Supply, Installation, Testing &Amp Commissioning Of Crt &Amp Intelligent Field Devices.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 78338879 |
|
Reference Number |
ENGG-JP-2024-25-101 |
| Tender Fee | 0 |
| EMD | 75500 |
| Tender Value | - |
| Place | Jaipur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/works/pdfdocs/122024/78338879/viewNitPdf_4766533.pdf |
| Start Date | November 14, 2024 17:16 |
| End Date |
Expired
05/12/2024
Expired 681 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Survey, design, manufacturing, installation, testing and commissioning of iot devices/ intelligent field devices(ifds) for monitoring & control (indian railways native iot based yield analysis telemetry, recording and control -ir-niyantrac) ) of electrical general assets like pumps, street lighting, lifts and substations etc. and integration of solar monitoring portal for dy. cee/colony area into ir-niyantrac.
Survey, design, manufacturing, installation, testing and commissioning of iot devices/ intelligent field devices(ifds) for monitoring & control (indian railways native iot based yield analysis telemetry, recording and control -ir-niyantrac) ) of electrical general assets like pumps, street lighting, lifts and substations etc. and integration of solar monitoring portal for dy. cee/colony area into ir-niyantrac.
Read moreCircuit breaker generator field - 90 amp emd part no.40072354, dlw pt.no.18310217
Circuit breaker generator field - 90 amp emd part no.40072354, dlw pt.no.18310217
Read moreRequest for proposal for selection of master system integrator (msi) to design, implement, integrate, operate and maintain intelligent traffic management system (itms) and adaptive traffic control system (atcs) for a duration of 10 years
Request for proposal for selection of master system integrator (msi) to design, implement, integrate, operate and maintain intelligent traffic management system (itms) and adaptive traffic control system (atcs) for a duration of 10 years
Read moreRenovation of toilet block of kabaddi play field of sai at vidhyadhar nagar stadium, jaipur
Renovation of toilet block of kabaddi play field of sai at vidhyadhar nagar stadium, jaipur
Read moreIntelligent universal programmer specification: (i) 48 pin dil/zif socket with respectable for 8 pin to 48 pin,300/600 mil devices.(ii) four dac for vcc,vpp1,vpp2 and vpp3 with 8 bit resolution. software controllable rise time and current limit protection.
Intelligent universal programmer specification: (i) 48 pin dil/zif socket with respectable for 8 pin to 48 pin,300/600 mil devices.(ii) four dac for vcc,vpp1,vpp2 and vpp3 with 8 bit resolution. software controllable rise time and current limit protection.
Read moreNipple grease conical head angled 1 4 an,nipple grease conical head angled 1 8 br,secondary fuel filter 1 liter star type,light ext ention inspection no 2 mk1 wi,poly v belt,speedometer assy,lever assy parking brake,spark plug n11yc,hatch roof assy vehicle,horn electrical f-8040700 6350-001098,wabco clutch booster alternate f-5p00500,ignition relay alt f7819400 f8355000,shift cylinder body,sealing ring 125x5 hhs 02 25125 h 5009,main brake valve -443 612 226 013,hand pump dhp 6002-21-81,clutch booster,starter motor 12 volts,field coil assy,slave cylinder,assy wiper blade,poly v belt1360 svl a c fan samsons,rep kit-clutch,repair kit for slave cylinder,assy handle outer door lh,door lock rh,assy rear view mirror outer lh,relay starter solenoid,assy arm wiper,repair kit for rear brake acuator,assy wiper blade 533 mm long,accelerator cable,separater fuel water,element primary,filter element fluid pressure,assy clutch pressure plate 330 dia,assy clutch disc 330 dia,alternator 24 volts 45 amp
Nipple grease conical head angled 1 4 an,nipple grease conical head angled 1 8 br,secondary fuel filter 1 liter star type,light ext ention inspection no 2 mk1 wi,poly v belt,speedometer assy,lever assy parking brake,spark plug n11yc,hatch roof assy vehicle,horn electrical f-8040700 6350-001098,wabco clutch booster alternate f-5p00500,ignition relay alt f7819400 f8355000,shift cylinder body,sealing ring 125x5 hhs 02 25125 h 5009,main brake valve -443 612 226 013,hand pump dhp 6002-21-81,clutch booster,starter motor 12 volts,field coil assy,slave cylinder,assy wiper blade,poly v belt1360 svl a c fan samsons,rep kit-clutch,repair kit for slave cylinder,assy handle outer door lh,door lock rh,assy rear view mirror outer lh,relay starter solenoid,assy arm wiper,repair kit for rear brake acuator,assy wiper blade 533 mm long,accelerator cable,separater fuel water,element primary,filter element fluid pressure,assy clutch pressure plate 330 dia,assy clutch disc 330 dia,alternator 24 volts 45 amp
Read moreGrowler,set of rowel punch 8, 10 mm,autotransformer 250v, 0 to 300 v,10a,solid state solar based single phase energy meter, bidirectional, 5 to 30 amps, 240 volts,three phase kwh meter analog 25a, 415 v a. c,three phase kwh meter digital 25a, 415 v a. c,wiring board on stand 3 meter x 1 meter with 0.5 meter projection on the top,limit switch, liver operated 2a 500v, 2 contacts,cut out relays 16a, 440v,under voltage relay 360v to 440v,earth electrode primary electrode 2100x28x3.25mm,earth electrode secondary cu strip 20x5mm,bus bar with brackets 1 mtr each,solar panels 250 wp,solar panels 15 wp,solar charge controller with manual switch, day lighting 6v,5 a,dc power supply 250v dc, 25 amp,automatic reverse forward er,soft er 1 ph,field regulator 0 to 1000 ohmic, 2 amps,d.c. shunt motor 3 h.p 250 v with 3 point er and speed regulator, laboratory type,immersion heater 1500 watt, 240v,ac table fan 68 watt, 230 v,dmx controller,rewinding machine,demonstration table 2.5 x 1.25 x 0.75 m,blackboard wit
Growler,set of rowel punch 8, 10 mm,autotransformer 250v, 0 to 300 v,10a,solid state solar based single phase energy meter, bidirectional, 5 to 30 amps, 240 volts,three phase kwh meter analog 25a, 415 v a. c,three phase kwh meter digital 25a, 415 v a. c,wiring board on stand 3 meter x 1 meter with 0.5 meter projection on the top,limit switch, liver operated 2a 500v, 2 contacts,cut out relays 16a, 440v,under voltage relay 360v to 440v,earth electrode primary electrode 2100x28x3.25mm,earth electrode secondary cu strip 20x5mm,bus bar with brackets 1 mtr each,solar panels 250 wp,solar panels 15 wp,solar charge controller with manual switch, day lighting 6v,5 a,dc power supply 250v dc, 25 amp,automatic reverse forward er,soft er 1 ph,field regulator 0 to 1000 ohmic, 2 amps,d.c. shunt motor 3 h.p 250 v with 3 point er and speed regulator, laboratory type,immersion heater 1500 watt, 240v,ac table fan 68 watt, 230 v,dmx controller,rewinding machine,demonstration table 2.5 x 1.25 x 0.75 m,blackboard wit
Read moreSupply of field toilet block 06 seater relocatable,deatchable ms steps as per drawing and specification,stainless steel indian water cloiwc s trap thickness 1 point 5mm grade,stainless steel wash hand basin,cp towel rod of 18 inch length make isi marked,cp tap weight not less than 450 gm,cp pillar tap for whb weight not less than 450 gm,cp steel soap dish isi marked,plastic cabinet fitted with looking glass of size 1.5 ft x 2 ft with isi marked,500 ltr capacity water tank isi marked 4 layer cover with iron cage,pvc wire insulated cable 1 point 5 sqmm,pvc wire insulated cable 2 point 5 sqmn,pvc casing capping 20 mm size make topson or plaza or polyplast,5 pin 5 amps switch socket combination with pvc mounting box,11 watt led with lamp as approved to be placed on the wash hand basin,11 watt led with bakelite angle holder,power point of 5 pin 15 amp socket and switch combination of modular type,exhaust fan of 250mm sweep single phase 230 or 240 volt with shutter,mcb dp 32 amps conforming to is 2282 to 1996,c
Supply of field toilet block 06 seater relocatable,deatchable ms steps as per drawing and specification,stainless steel indian water cloiwc s trap thickness 1 point 5mm grade,stainless steel wash hand basin,cp towel rod of 18 inch length make isi marked,cp tap weight not less than 450 gm,cp pillar tap for whb weight not less than 450 gm,cp steel soap dish isi marked,plastic cabinet fitted with looking glass of size 1.5 ft x 2 ft with isi marked,500 ltr capacity water tank isi marked 4 layer cover with iron cage,pvc wire insulated cable 1 point 5 sqmm,pvc wire insulated cable 2 point 5 sqmn,pvc casing capping 20 mm size make topson or plaza or polyplast,5 pin 5 amps switch socket combination with pvc mounting box,11 watt led with lamp as approved to be placed on the wash hand basin,11 watt led with bakelite angle holder,power point of 5 pin 15 amp socket and switch combination of modular type,exhaust fan of 250mm sweep single phase 230 or 240 volt with shutter,mcb dp 32 amps conforming to is 2282 to 1996,c
Read moreSupply & installation of intelligent field devices (ifd ) : sdah divn: provision of iot devices for monitoring and control of electrical general assets.
For complete deion and other details, please refer to tender
Read moreProvision of iot devices/intelligent field devices (ifds) for monitoring & control over jhansi division.
For complete deion and other details, please refer to tender
Read moreof your Industry type