| Title |
E Nit No. Micd 1 Of 2026 27 Dated 09 04 2026 Repairing, Maintenance Of 1300 Mm Nd Control Valves Viz. Butterfly Valve, Dpcv, Dismantling Joint Etc. Fitted At Rd 50 Of 1300 Mm Nd Rising Main Of Lis Tral Stage 2nd
|
| Description |
Repairing, Maintenance Of 1300 Mm Nd Control Valves Viz. Butterfly Valve, Dpcv, Dismantling Joint Etc. Fitted At Rd 50 Of 1300 Mm Nd Rising Main Of Lis Tral Stage 2nd
|
| Organisation | I and FC | State Govt. and UT |
| Tender Id | 2026_IFC_307599_1 |
|
Reference Number |
e- NIT No. MICD 1 OF 2026-27 Dated 09-04-2026 |
| Tender Fee | 100 |
| EMD | 900 |
| Tender Value | - |
| Place | Tral Stage 2nd |
| Link |
View Original Tender Notice
https://jktenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=997812 |
| Start Date | April 09, 2026 21:30 |
| End Date |
Expired
20/04/2026
Expired 180 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Nit no micd 30 of 2026-27 dated 13.10.2026 rectification of leakages for 1200mm dia ms rising main and 400 mm dia ms delivery pipe of unit no 4 at lis tral stage 3rd
Rectification of leakages for 1200mm dia ms rising main and 400 mm dia ms delivery pipe of unit no 4 at lis tral stage 3rd
Read moreNit no micd 30 of 2026-27 dated 13.10.2026 overhauling and testing of set of 3- phase pt system of 11 kv incomer unit and servicing of all vcbs affected by flashover at stage 3rd lis tral
Overhauling and testing of set of 3- phase pt system of 11 kv incomer unit and servicing of all vcbs affected by flashover at stage 3rd lis tral
Read moreE nit 6 of 2024-25 dated 15-05-2024maintenance of 1300 mm dia control valves of dpcv, dismantling joint, expansion joint and butterfly valve of 1300 mm dia rising main lis tral stage 2nd
Maintenance of 1300 mm dia control valves of dpcv, dismantling joint, expansion joint and butterfly valve of 1300 mm dia rising main lis tral stage 2nd
Read moreE- nit no. micd 2 of 2025-26 dated 23-04-2025maintenance of 1300 mm dia control valves of dpcv , expansion joint
Maintenance of 1300 mm dia control valves of dpcv , expansion joint &#x0d of 1300 mm dia rising main lis tral stage 2nd&#x0d
Read moreE- nit no. micd 30 of 2025-26 dated 18-06-2025execution of electrical and mechanical repairs and replacement works at lis tral stage 3rd and lis tral stage 2nd
Execution of electrical and mechanical repairs and replacement works at lis tral stage 3rd and lis tral stage 2nd
Read moreReplacement of wornout 200 mm nd rising main by 250 nd ms pipe and 250 mm nrv at lis dar mohalla
Replacement of wornout 200 mm nd rising main by 250 nd ms pipe and 250 mm nrv at lis dar mohalla
Read moreE-nit micd/23 of 2023-24 dated 13.06.2023repairs of 6.3 mva 33/11 kv power transformer no 1 at lis tral stage 2nd
Repairs of 6.3 mva 33/11 kv power transformer no 1 at lis tral stage 2nd
Read moreProviding of 01 no. rubber expansion joint to be installed / fitted with 914 mm dia rising main at lis raya.
Providing of 01 no. rubber expansion joint to be installed / fitted with 914 mm dia rising main &#x0d at lis raya.
Read moreE- nit no. micd 35 of 2025-26 dated 06-08-2025repairs to 1500 mm dia rising main in wash out chamber (rd-100) at lis rafiabad
Repairs to 1500 mm dia rising main in wash out chamber (rd-100) at lis rafiabad
Read moreDetailed estimate for replacement of 02 no. rubber expansion joint installed/fitted with 914mm rising main at different rds at lis raya.
Detailed estimate for replacement &#x0d of 02 no. rubber expansion joint &#x0d installed/fitted with 914mm rising &#x0d main at different rds at lis raya.