Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Mccb, 1200 A, 4 P, Thermal Magnetic Release, Breaking Capacity 85 Ka, 415 V Ac, Make C&S Electric Li,M
|
| Description |
|
| Organisation | Materials Management | Ministry of Coal |
| Tender Id | GEM/2023/B/4185597 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://gem.gov.in/ |
| Start Date | November 09, 2023 17:48 |
| End Date |
Expired
29/11/2023
Expired 1054 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
S AND S COMPANY
1971992.4
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | EMD Status | MSE/MII Status | Status |
|---|---|---|---|---|---|---|
| 1 | ABHIJEET ENTERPRISES | Make : NA Model : NA Title : Universal | 25-11-2023 17:49:53 | Central / State PSUs | N/A | Evaluated |
| 2 | M/S NAWAGARH INDUSTRIAL STORE | Make : NA Model : NA Title : NA | 23-11-2023 17:06:05 | Central / State PSUs | N/A | Evaluated |
| 3 | S AND S COMPANY | Make : RESALLER Model : MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosur Title : MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosure | 23-11-2023 16:33:21 | Offline upload | N/A | Evaluated |
Ordered Items & Contract Pricing
| Product | Brand | Model | Ordered Quantity | Price |
|---|---|---|---|---|
| MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosure | RESALLER | MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosur | 16 | ₹ 713664.000 |
| MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosure | RESALLER | MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosur | 7 | ₹ 401436.000 |
| MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosure | RESALLER | MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosur | 5 | ₹ 323131.200 |
| MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosure | RESALLER | MCCB 1200A, 415V, 4PL, 3P BRKR, CRCT With Enclosur | 2 | ₹ 533761.200 |
100 amp 4 pole thermal magnetic module case circuit breaker (mccb)
100 amp 4 pole thermal magnetic module case circuit breaker (mccb)
Read moreLow voltage mccb with thermal magnetic/electronic trip unit conforming to is/iec 60947 (part 2)
Low voltage mccb with thermal magnetic/electronic trip unit conforming to is/iec 60947 (part 2)
Read moreLow voltage mccb with thermal magnetic/electronic trip unit conforming to is/iec 60947 (part 2)
Low voltage mccb with thermal magnetic/electronic trip unit conforming to is/iec 60947 (part 2)
Read moreMpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Mpcb for compressor unit 1.1, 1.2, 2.1 & 2.2, heater 1 & 2 rated current: 7-10a thermal release range:10-16a, class:10, breaking capacity: 10ka, pole:-3p, rated voltage:- 415vac as per rdso letter no. el/7.1.108/ mssbc dt. 17.09.2021 annexure (bom) sr. no. 39.
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreL and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
L and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
Read moreMpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Read moreAir circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Air circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
Read moreMpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Mpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Read moreMotor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Read moreof your Industry type