Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Reconditioning Of 11 Kv Vcb Make Meditron, S.No.9473 Installed With Secondary Control Of On Load Isolator And 3.3 Kv Vcb Of Make Mine Line S.No.254 Installed With Primary Control Of Bus Bar At Main Substation Of Karma Ocp Under Kuju Area.
|
| Description |
Repairing And Reconditioning Of 11 Kv Vcb Make Meditron, S.No.9473 Installed With Secondary Control Of On Load Isolator And 3.3 Kv Vcb Of Make Mine Line S.No.254 Installed With Primary Control Of Bus Bar At Main Substation Of Karma Ocp Under Kuju Area.
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_CCL_315392_1 |
|
Reference Number |
GM (K)/EnM/eTender/24-25/107 |
| Tender Fee | 0 |
| EMD | 3800 |
| Tender Value | - |
| Place | GM UNIT KUJU |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=353127 |
| Start Date | August 01, 2025 16:30 |
| End Date |
Expired
11/08/2025
Expired 431 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreRepairing/reconditioning of 11kv vcb make meditron, s.no.9472 and 11kv vcb of make meditron s.no.9474 installed at main substation of karma ocp under kuju area.
Repairing/reconditioning of 11kv vcb make meditron, s.no.9472 and 11kv vcb of make meditron s.no.9474 installed at main substation of karma ocp under kuju area.
Read moreRepairing and reconditioning of 11kv vcb make electroteknica s.no. 1735 installed with secondary control of on load isolator and 11kv vcb of make meditron s.no. 9480 installed with primary control of bus bar at main substation of karma ocp .
Repairing and reconditioning of 11kv vcb make electroteknica s.no. 1735 installed with secondary control of on load isolator and 11kv vcb of make meditron s.no. 9480 installed with primary control of bus bar at main substation of karma ocp.
Read moreRepairing and reconditioning of 01 no. 11kv,400amp, s.no. 94/80 make-meditron vcb switch installed at main substation of karma ocp under kuju area.
Repairing and reconditioning of 01 no. 11kv,400amp, s.no. 94/80 make-meditron vcb switch installed at main substation of karma ocp under kuju area.
Read moreRepairing/reconditioning of 02 nos vcb (a) 3.3kv,400amp, mineline make vcb s.no.(b) 11kv ,400amp,meditron make vcb s.no.9472 at main substation of karma project under kuju area.
Repairing/reconditioning of 02 nos vcb (a) 3.3kv,400amp, mineline make vcb s.no.(b) 11kv ,400amp,meditron make vcb s.no.9472 at main substation of karma project under kuju area.
Read moreRepairing and reconditioning of 11kv ,400a vcb electrotecknica make s.no. sgo-1705 and 3.3kv ocb 400a reyroll burne make s.no. 84/326 installed at karma project under kuju area.
Repairing and reconditioning of 11kv ,400a vcb electrotecknica make s.no. sgo-1705 and 3.3kv ocb 400a reyroll burne make s.no. 84/326 installed at karma project under kuju area.
Read moreInstallation of rectifier system in 07 nos. of 11kv/3.3 kv vcb, 630 amp and 400 amp vcb make meditron and mineline respectively at main substation of karma project under kuju area.
Installation of rectifier system in 07 nos. of 11kv/3.3 kv vcb, 630 amp and 400 amp vcb make meditron and mineline respectively at main substation of karma project under kuju area.
Read moreRepairing and reconditioning of 02 nos. mineline make outdoor vcb 3.3kv 400a , s.no.290 and 286 respectively at karma project under kuju area.
Repairing and reconditioning of 02 nos. mineline make outdoor vcb 3.3kv 400a , s.no.290 and 286 respectively at karma project under kuju area.
Read moreMaintenance and reconditioning of 400 amp,11kv electrotenkica make vcb installed at main substation of karma project under kuju area
Maintenance and reconditioning of 400 amp,11kv electrotenkica make vcb installed at main substation of karma project under kuju area
Read moreRepairing and reconditioning of 1 no. 11kv meditron make vcb and 01 no. 3.3kv mineline make vcb installed at main substation and mines of topa ocp under kuju area.
Repairing and reconditioning of 1 no. 11kv meditron make vcb and 01 no. 3.3kv mineline make vcb installed at main substation and mines of topa ocp under kuju area.
Read moreof your Industry type