π Procurement Opportunity For Auxiliary Contact Blocks π§π The Ministry Of Railways, Specifically The Central Government Ministry/Department, Is Seeking Bids For The Supply Of Auxiliary Contact Blocks, Type Te Sys D, With Specific Electrical Ratings And Terminal Configurations. πΌ π Location: Secunderabad ποΈ Deadline: May 23, 2024, 2:30 Pm Bids Should Include All Necessary Technical Details And Conform To Iec 60947 5 1 Standards. π A Sample Unit Must Be Submitted For Approval Prior To The Bulk Supply Agreement. π οΈ Please Refer To The Tender Document For Complete Details And Specifications. Keywords: Auxiliary Contact Block, Te Sys D, Electrical Equipment, Ministry Of Railways, Tender, Procurement, Secunderabad, Iec 60947 5 1, Schneider, Railways InfrastructureParticulars | Details |
---|---|
Title |
Auxiliary Contact Block, Type Te Sys D, 2 N/O Plus 2 N/C, Front Mounting Screw Clamp Terminals, Rated Operational Voltage(ue) : 690 V Ac 400 Hz, Rated Insulation Voltage(ui) : 690 V Confirming To Iec 60947 5 1, Rated Operational Current(le) : 6 A At 120 V Ac 15, Ladn22 Of M/S. Schneider Make.
Note: One Sample Should Be Got Approved Before Effecting Bulk Supply.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106325004 |
Reference Number |
LB245348 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Secunderabad |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/052024/106325004/viewNitPdf_4547320.pdf |
Start Date | April 23, 2024 17:55 |
End Date |
23/05/2024 ( Expired 365 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Contactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read moreSupply, installation, testing & commissioning of mccb 400 amp 4 pole, as per is/iec:60947 part-2:2003 latest, isi marked, breaking current: 36 ka, rated short circuit capacity (in ka): mccb with rscb capacity of 10/16/25/35 ka tripping range, rated voltage (volt) ? 240/415 volt 50 hz ac.
For complete deion and other details, please refer to tender
Read moreExtension board made of abs/polycarbonate material consisting of the following components. 1) three nos of five pin sockets and plug of each 32 a capacity with ip 44 and higher rating suitable for 415 v three phase connections. 2) 4 pole mcb with rated current: 63 a, rated voltage :415 v ac conforming to en/iec 60898-1. 3) 2.5 sq.mm, 3 core copper cable wire of 15 meters length conforming to is-694:2010. note: all the components to be fitted and wired in the extension board and should be o
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) : 2.5-4.0 a, class 10, breaking capacity : 50 ka, 3 pole, rated voltage 415 v ac, 1 no 1 nc auxiliary contact block as per rdso common bill of material letter no el/7.108/mssbc dated 17.09.21, make- abb catalogue no ms 116-4 / legrand / eaton / schneider catalogue no gv2me08gvae11/ l&t catalogue no st418960000/ siemens catalogue no 3rv2011 1ea103rv2901-1e only.
For complete deion and other details, please refer to tender
Read moreMcb 2 pole 10 amps. make: l&t / abb / siemens / schneider /legrand. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord / sidwal fitted in conventional electric locos to rdso specification no: rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
For complete deion and other details, please refer to tender
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degree c and utilization category 6 a, main pole 4, auxiliary contact: 2 no 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev 1) and as per of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt. 17/09/21 to schneider cat. no. lc1d1150046n5 la4da2n ladn22, abb catalogue no. af
For complete deion and other details, please refer to tender
Read moreContactor of 9 amps for cab ac of wag7 locomotives. make: l&t/siemens/schneider/ge or similar. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord / sidwal fitted on conventional electric locos to rdso specification no: rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
For complete deion and other details, please refer to tender
Read moreMpcb 1-1.6 amps. make: l&t / abb / siemens / schneider. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram / fedders lylord / sidwal fitted in conventional electric locos to rdso specification no: rdso/2007/el/spec/0055 rev.2 of nov 2007/revised on 07.10.2014. 2) one sample to be got approved before effecting bulk supply.
For complete deion and other details, please refer to tender
Read more[hrc fuse din type current rating 125 amps, voltage rating 1000 volts, breaking capacity 80ka or 100ka size nh1l, category gb dimensions for lhb ac coaches as per rdso specification no rdso/pe/spec/0184-2015 (rev 1) suitable to fitment in existing hrc fuse holder place of installation sif50 tosif55 of switch board cabinet of lhb ac coaches. note: (1) test, guarantee, warranty certificates to accompany at the time of supply. (2) one sample should be got approved by consignee before bulk supply