Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Connectivity Road Should Be Constructed From Main Road To Fstp Plant Khavda Sapotra
|
| Description |
Connectivity Road Should Be Constructed From Main Road To Fstp Plant, Khavda Sapotra
|
| Organisation | DLB | State Govt. and UT |
| Tender Id | 2025_DLB_515043_1 |
|
Reference Number |
NIT1280 |
| Tender Fee | 1000 |
| EMD | 41760 |
| Tender Value | - |
| Place | SAPOTRA |
| Link |
View Original Tender Notice
https://eproc.rajasthan.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=918746 |
| Start Date | November 22, 2025 17:35 |
| End Date |
Expired
01/12/2025
Expired 321 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read moreHydraulic oil brand: ioc (barrel should be ms only)
Hydraulic oil brand: ioc (barrel should be ms only)
Read more1) tapered drill router should be compatible with existing stryker neuro drill system, 2) lindemann drill bit should be compatible with existing stryker neuro drill system, 3) pd series perforator chuck should be compatible with existing stryker neuro drill system & 4) perforated drill bit large should be compatible with existing stryker neuro drill system
1) tapered drill router should be compatible with existing stryker neuro drill system, 2) lindemann drill bit should be compatible with existing stryker neuro drill system, 3) pd series perforator chuck should be compatible with existing stryker neuro drill system & 4) perforated drill bit large should be compatible with existing stryker neuro drill system
Read moreSpo2 sensor probe for use with multiparameter monitor of make g3d. the probe should be minimum 3 metres in length.each probe should be individually packed.
Spo2 sensor probe for use with multiparameter monitor of make g3d. the probe should be minimum 3 metres in length.each probe should be individually packed.
Read moreFloor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.
Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.
Read moreTab/cap . bilastine 20 mg. ( product should be in railway board)
Tab/cap . bilastine 20 mg. ( product should be in railway board)
Read moreSolid state relay for control safety loop, dc3-32 v confirming to rcf specification no. edts 103 rev-d, am-7. material is rd0605-d of m/s carlo gavazzi/abb/siemens or equivalent. note: 1) material should be should be supplied by oem or their authorised dealers only & dealership certificate should be uploaded while bidding. 2) test certificate & guaranty certificates should be supplied along with materials.
Solid state relay for control safety loop, dc3-32 v confirming to rcf specification no. edts 103 rev-d, am-7. material is rd0605-d of m/s carlo gavazzi/abb/siemens or equivalent. note: 1) material should be should be supplied by oem or their authorised dealers only & dealership certificate should be uploaded while bidding. 2) test certificate & guaranty certificates should be supplied along with materials.
Read moreSuture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.
Suture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.
Read moreChlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be
Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be
Read morePacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b
Read moreof your Industry type