Particulars | Details |
---|---|
Title |
Supply, Delivery And Fixing Of 600mm Dia Butterfly Valves And 600mm Dia Non Slam Type Nozzle Check Valves (Nrv) For 1300/1475/1425 Kw Pumpsets At 6.6 Kv Phase Iii Pumping Stations At Kodandapur, Nasarlapally And Godakondla Under Electrical Sub Division, Om Div.No.Xi, Sahebnagar
|
Description |
Supply, Delivery And Fixing Of 600mm Dia Butterfly Valves And 600mm Dia Non Slam Type Nozzle Check Valves (Nrv) For 1300/1475/1425 Kw Pumpsets At 6.6 Kv Phase Iii Pumping Stations At Kodandapur, Nasarlapally And Godakondla Under Electrical Sub Division, Om Div.No.Xi, Sahebnagar
|
Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
Tender Id | 500425 |
Reference Number |
EP.No.103/CGM(E)/TC/T3/OM Div.XI/2023-24 dt:19.02.2024 |
Tender Fee | 6995 |
EMD | 1.98 Lakh |
Tender Value | |
Place | TS |
Link | http://eprocurement.telangana.gov.in/ |
Start Date | February 21, 2024 20:30 |
End Date |
28/02/2024 ( Expired 485 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
T,e,t comm of 33/6.6kv electrical substation including existing 4 nos of 3150kva power transformers, electrical panels, cabels, 33kv overhead line and all allied equipment to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kpur, npally and gkondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, om div.xi, saheb
Transportation, erection, testing and commissioning of 33/6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreT e and c of existing 6.6kv, 300 hp bha 700h pumpsets 600 hp submersible pump sets near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment under td-iii, sahebnagar
Transportation, erection, testing and commissioning of existing 6.6kv, 300hp, bha 700h pump sets, 600hp submersible pump sets and all allied works and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed at nagarjunasagar reservoir under eam section, sd-iv(electrical), transmission div.iii, sahebnagar
Read moreR,t comm of 33 6.6kv, 2500kva ptr sdit and comm of motor ers providing of gabions and formation of bund across main canal to maintain required level in canal for emergency pumping arrangement at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreR t comm of 33 6.6kv 2500kva ptr sdit comm of motor ers providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreTet nd c 33 6.6kv electrical substation including existing 4 no of 3150 kva power transformer to feed the power supply to emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Transportation, erection, testing and commissioning of 33 6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation,dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreT,e and c of existing 6.6kv, 300hp, bha700h pump sets, 600hp submersible pump sets near puttamgandi including mom of pumping station of 4 months and dismantling and transportation of all equipmentto kpur, gkondla and under td-iii, sahebnagar
Transportation, erection, testing and commissioning of existing 6.6kv, 300hp, bha 700h pump sets, 600hp submersible pump sets and all allied works and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed at nagarjunasagar reservoir under eam section, sd-iv(electrical), transmission div.iii, sahebnagar
Read moreRefurbishment upgradation of existing old system including supply, delivery, erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing reconditioning of non valves, supply and fixing of bf valves along with accessories etc under mdwss ph-ii, iii iv under electrical division, s.r.nagar, hyderabad.
Refurbishment and upgradition of existing old system including supply, delivery, erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing reconditioning of non valves, supply and fixing of bf valves along with accessories etc, under manjira drinking water supply scheme, phase-ii, iii iv, of under electrical division, s.r.nagar, hyderabad.
Read moreSupply, delivery of 500mm dia pn 25/class 150 rated, non- valves and 500mm dia pn-16 rated, butterfly valves in place damaged valves and laying of 300mm x 50mm x 2mm thick gi ladder type cable tray for 300 sq.mm ht cable for spare feeder from substationto ph-iii, pump house at peddapur ph-iii and iv using pumping stations along with accessories etc under mwss, ph-iii and iv under td-ii, patancheru.
Supply and delivery of 500mm dia pn 25/class 150 rated, non- valves and 500mm dia pn-16 rated, butterfly valves in place damaged valves and laying of 300mm x 50mmx2mm thick gi ladder type cable tray for 300sq.mm ht cable for spare feeder from substation to phase-iii, pump house at peddapur phase-iii and iv pumping stations along with accessories etc, under manjira drinking water supply scheme, phase-iii and iv under transmission division no.ii, patancheru
Read moreRefurbishment upgradation of existing old system including supply, delivery, erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing reconditioning of non valves, supply and fixingof bf valves along with accessories etc under mdwss ph-ii, iii iv under electrical division, s.r.nagar, hyderabad.
Refurbishment upgradation of existing old system including supply, delivery, erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing reconditioning of non valves, supply and fixing of bf valves along with accessories etc, under manjira drinking water supply scheme, phase-ii, iii iv, of under electrical division, s.r.nagar, hyderabad.
Read moreRefurbishment and upgradation of existing old system including supply, delivery, erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing and reconditioning of non valves, supply and fixingof bf valves along with accessories etc under mdwss ph-ii, iii iv under electrical division, s.r.nagar, hyderabad.
Refurbishment and upgradation of existing old sytem including, supply, delivery,erection, testing and commissioning of 6.6kv ht panels at kalabgoor and 3.3kv ht panels at patancheru, phase-ii, pumping stations and repairing and reconditioning of non return valves, supply and fixing of bf valves along with accesspries etc under mdwss, phase-ii, iii iv under electrical division, s.r.nagar, hyderabad