Tender Details
Check your funding eligibility in 2 minutes.
Answer a few questions and our team will contact you with your best options.
Particulars | Details |
---|---|
Title |
Supply, Delivery And Fixing Of Various Mandatory Spares For 132/6.6 Kv Substations Having 12/16 Mva Power Transformers And 6.6 Kv Pumping Stations Having 36 Nos Of 1300/1475/1425 Kw Pumpsets For Phase Iii Pumping Stations At Kodandapur, Nasarlapally, Godakondla And Other Stations Under Electrical Sub Division, Om Div.No.Xi,Sahebnagar
|
Description |
Supply, Delivery And Fixing Of Various Mandatory Spares For 132/6.6 Kv Substations Having 12/16 Mva Power Transformers And 6.6 Kv Pumping Stations Having 36 Nos Of 1300/1475/1425 Kw Pumpsets For Phase Iii Pumping Stations At Kodandapur, Nasarlapally, Godakondla And Other Stations, Under Electrical Sub Division, O M Division Xi, Sahebnagar
|
Organisation | Information Technology Electronics and Communication Department Telangana | State Govt. and UT |
Tender Id | 501053 |
Reference Number |
EP.No.74/2nd call/CGM(E)/TC/T3/OM Div.XI/2023-24 dt:21.02.2024 |
Tender Fee | 7042 |
EMD | 1.99 Lakh |
Tender Value | |
Place | TS |
Link | http://eprocurement.telangana.gov.in/ |
Start Date | February 22, 2024 20:30 |
End Date |
29/02/2024 ( Expired 494 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Annual maintenance of 2200mm dia/2375mm dia ms pumping main 76kms and gravity main of 36kms kodandapur to sahebnagar 9ml and 9ml clear water reservoirs of ph-i 18ml clear water reservoirs of phase-ii and phase-iii in the premises at kpur, npally and gkondla and 6 nos of 22.50 ml mbr of kdwso ph-i,ii iii in the premises at gungal under sd.i, td-iii, sahebnagar for a period of two years
Annual maintenance of 2200/2375 mm dia ms pumping main 76kms and gravity main of 38 kms from kodandapur to sahebnagar, 9ml and 9ml clear water reservoirs of phase-i, 18ml clear water reservoirs of phase-ii and phase-iii in the premises at kodandapur , nasarlapally and godakondla and 6 nos of 22.50ml master balancing reservoirs of kdwsp phase-i,ii and iii in the premises at gungal,sd-i, td-iii, sahebngar for the period of (two) 02 years
Read moreRefurbishment of existing 2000amps 6.6kv, vcb panels including supply, delivery,erection, testing and commissioning of 6.6kv ht vcb panels at ph-i of 132/6.6kv sub-statios bearing housing and vcbs for 1425kw, 1475kw and 1300kw pump sets at kodandapur, nasarlapally and godakondla under eam section, electrical sub division,td-iii, sahebnagar
Refurbishment of existing 2000 amps 6.6 kv, vcb panel including supply, delivery, erection, testing and commissioning of 6.6kv ht vcb panels at phase-i of 132 6.6kv substations, bearing housing and vcbs for 1425kw, 1475 kw and 1300 kw pump sets at kodandapur, nasarlapally and godakondla under eam section electrical sub division, transmission division no.iii, sahebnagar.
Read moreS d and f of acbs mechanical seals fcma module motor shafts 1600 1 1 amps cts for incomers bearing housings and vcbs for 1425 kw pump sets and protection relays for 132 kv line and 12 16 mva power transformers for ph i pump houses at k pur, n pally and g kondla under eam section td-iii, sahebnagar
Supply, delivery and fixing of air circuit breakers mechanical seals fcma module motor shafts1600 1 1 amps cts for incomers bearing housings and vcbs for 1425kw 1475 kw 1300 kw pump sets and protection relays for 132kv line and 12 16 mva power transformer feeders for phase i pump houses at kodandapur nasarlapally and godakondla under eam section sd iv of transmission division no.iii, saheb nagar.
Read moreT,e,t comm of 33/6.6kv electrical substation including existing 4 nos of 3150kva power transformers, electrical panels, cabels, 33kv overhead line and all allied equipment to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kpur, npally and gkondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, om div.xi, saheb
Transportation, erection, testing and commissioning of 33/6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation, dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreT e and c of existing 6.6kv, 300 hp bha 700h pumpsets 600 hp submersible pump sets near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment under td-iii, sahebnagar
Transportation, erection, testing and commissioning of existing 6.6kv, 300hp, bha 700h pump sets, 600hp submersible pump sets and all allied works and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed at nagarjunasagar reservoir under eam section, sd-iv(electrical), transmission div.iii, sahebnagar
Read moreR,t comm of 33 6.6kv, 2500kva ptr sdit and comm of motor ers providing of gabions and formation of bund across main canal to maintain required level in canal for emergency pumping arrangement at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreR t comm of 33 6.6kv 2500kva ptr sdit comm of motor ers providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Rewinding, testing commissioning of 33 6.6kv, 2500kva ptr ,supply, delivery, installation, testing commissioning of motor ers, air-circuit breaker, repairing of pumps and motors, providing of gabions and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi and also dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir under eam section, sub division-iv, transmission div no.iii, sahebnagar
Read moreTet nd c 33 6.6kv electrical substation including existing 4 no of 3150 kva power transformer to feed the power supply to emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi under td-iii, sahebnagar
Transportation, erection, testing and commissioning of 33 6.6 kv electrical substation including existing 4 no of 3150kva power transformers, electrical panels, cables, 33kv over head line and all allied electrical equipement to feed the power supply to emergency pumping arrangements at foreshore of nagarjuna sagar near puttamgandi including 4 months mom for substation,dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed to nagarjunasagar reservoir, under eam section, electrical sub division,transmission div.iii, sahebnagar
Read moreT,e and c of existing 6.6kv, 300hp, bha700h pump sets, 600hp submersible pump sets near puttamgandi including mom of pumping station of 4 months and dismantling and transportation of all equipmentto kpur, gkondla and under td-iii, sahebnagar
Transportation, erection, testing and commissioning of existing 6.6kv, 300hp, bha 700h pump sets, 600hp submersible pump sets and all allied works and formation of bund across the approach main canal to maintain required level in canal for emergency pumping arrangements at foreshore of nagarjunasagar near puttamgandi including mom of pumping station for 4 months and dismantling and transportation of all equipment to kodandapur, nasarlapally and godakondla whenever sufficient inflows ed at nagarjunasagar reservoir under eam section, sd-iv(electrical), transmission div.iii, sahebnagar
Read moreMom of (i) 132/6.6 kv substation having 2 nos of 10/16 mva power transformers along with allied equipment required spares at peddapur 132/6.6 kv substation under eam cell-ii, peddapur, td-ii, patancheru (ii) 11/3.3 kv substation having 2 nos x 1000 kva transformers
Manning, operation and maintenance of (i) 132/6.6 kv substation having 2 nos of 10/16mva power transformers along with allied equipment required spares at peddapur 132/6.6 kv substation under eam cell-ii, peddapur, transmission division no.ii,patancheru (ii) 11/3.3 kv substation having 2 nos x 1000 kva transformers, 11/0.433kv, 500kva and 250kva auxiliary transformers along with allied equipment and 3.3kv pumping station having 3 nos 220kw/3.3 kv and 1 no x 110 kw/3.3 kv vertical pump sets along with allied equipment at jack well, singoor under eam cell-ii, peddapur,transmission division no.ii, patancheru for a period of one(1) year.
Read moreof your Industry type