Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Complete Con Of 11kv 550 V 500 Kva Power Transformer To 3.3 Kv 550 V Power Transformer Installation And Commissioning Of Cm Project At Nakrakonda Kumardihi B Colliery Under Bankola Area.
|
| Description |
Complete Con Of 11kv 550 V 500 Kva Power Transformer To 3.3 Kv 550 V Power Transformer Installation And Commissioning Of Cm Project At Nakrakonda Kumardihi B Colliery Under Bankola Area.
|
| Organisation | Eastern Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_ECL_305043_1 |
|
Reference Number |
ECL/GM/BA/E TENDER/23-24/EnM/430 Dt. 14.03.2024 |
| Tender Fee | 0 |
| EMD | 6400 |
| Tender Value | - |
| Place | Nakrakonda Kumardihi B Colliery |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=316058 |
| Start Date | March 14, 2024 20:30 |
| End Date |
Expired
25/03/2024
Expired 933 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Complete repairing and rewinding of 93.3kw,120hp marathon make 1470rpm 550volt pump motor of nakrakonda kumardihi b colliery under bankola area
Complete repairing and rewinding of 93.3kw,120hp marathon make 1470rpm 550volt pump motor of nakrakonda kumardihi b colliery under bankola area
Read morePole, pcc, 9 m,fixt lighting, 230 v, 150 w, led, screw,cable, 1.1 kv, 2c, copper, pvc, 1.5 mm2, flexible,overload relay, thrml, 100-150 a,ictp switch, 415-550v, 32 a, 3 p,cable joint kit, 35mm2, copper, 3.3 v, 3 c,earth leakage relay, 50-750 ma with time lag with cbct,moving contact,fixed contact,potential transformer 550-220v, 50va
Pole, pcc, 9 m,fixt lighting, 230 v, 150 w, led, screw,cable, 1.1 kv, 2c, copper, pvc, 1.5 mm2, flexible,overload relay, thrml, 100-150 a,ictp switch, 415-550v, 32 a, 3 p,cable joint kit, 35mm2, copper, 3.3 v, 3 c,earth leakage relay, 50-750 ma with time lag with cbct,moving contact,fixed contact,potential transformer 550-220v, 50va
Read moreOandm watersupply schemes w s s to n paravur municipalityand adjoing panchayath supply of spare parts and rectify oil leak from bushings by changing gaskets and oil seals of 250 kva 11kv 433 v outdoor transformer at north paravur pump house
Oandm watersupply schemes w s s to n paravur municipalityand adjoing panchayath supply of spare parts and rectify oil leak from bushings by changing gaskets and oil seals of 250 kva 11kv 433 v outdoor transformer at north paravur pump house
Read moreSupply, erection, testing and commissioning of the following works on turnkey basis in narayanpet district under makthal-narayanpet-kodangal lift irrigation scheme(package-3) i) 220/11kv liss at jayamma cheruvu, perapalla(v), narayanpet(m). ii) 220kv tmdc line from existing 220/132kv kosigiss to proposed 220/11kvss at jayamma cheruvu ss (27.298km). iii) 2nos. 220kv bays at 220/132kv ss kosigi. iv) 1no.132/11kv transformer bay at existing 132/11kv panchadevpahad ss
Supply, erection, testing and commissioning of the following works on turnkey basis in narayanpet district under makthal-narayanpet-kodangal lift irrigation scheme(package-3) i) 220/11kv liss at jayamma cheruvu, perapalla(v), narayanpet(m). ii) 220kv tmdc line from existing 220/132kv kosigiss to proposed 220/11kvss at jayamma cheruvu ss (27.298km). iii) 2nos. 220kv bays at 220/132kv ss kosigi. iv) 1no.132/11kv transformer bay at existing 132/11kv panchadevpahad ss
Read moreFuse cartage, ht 2a, 3.3 kv,coil, 110v, oprt,flood light, led, 100w, ip65, w 10 nos, 10,plug insulator with tube set,thermal overload relay,earth leakage relay, 110v rating elm 8,potential transformer,isolator reversing 300a,contactor, main, 550v, 300a,relay digital, led,24-260vac, 24-360 v dc, 1a-5a,hrc fuse,moving contract assembly,spndl, ss, w-brs nut, f-ft valve - size8 in,cable 1.1 kv, 2c, copper, pvc, 1.5mm2, flexible
Fuse cartage, ht 2a, 3.3 kv,coil, 110v, oprt,flood light, led, 100w, ip65, w 10 nos, 10,plug insulator with tube set,thermal overload relay,earth leakage relay, 110v rating elm 8,potential transformer,isolator reversing 300a,contactor, main, 550v, 300a,relay digital, led,24-260vac, 24-360 v dc, 1a-5a,hrc fuse,moving contract assembly,spndl, ss, w-brs nut, f-ft valve - size8 in,cable 1.1 kv, 2c, copper, pvc, 1.5mm2, flexible
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read morePartial rewinding and repairing of 750kva, 11kv/440volt transformer of nakrakonda-kumardihi b colliery under bankola area.
Partial rewinding and repairing of 750kva, 11kv/440volt transformer of nakrakonda-kumardihi b colliery under bankola area.
Read moreRepairing and rewinding of 630 kva ,11kv/440v transformer of nakrakonda kumardihi b colliery under bankola area.
Repairing and rewinding of 630 kva ,11kv/440v transformer of nakrakonda kumardihi b colliery under bankola area.
Read moreInstallation and commissioning of 3.3 kv oh line and lighting transformer in nakrakonda oc project at nakrakonda kumardihi b colliery under bankola area
Installation and commissioning of 3.3 kv oh line and lighting transformer in nakrakonda oc project at nakrakonda kumardihi b colliery under bankola area
Read moreDomestic wiring of 11 kv substation building and transformer house of cm project at nakrakonda kumardihi b colliery bankola area.
Domestic wiring of 11 kv substation building and transformer house of cm project at nakrakonda kumardihi b colliery bankola area.
Read moreof your Industry type