| Title |
For The Work Of Providing And Installation Of 33 Kv/110 Volt Single Phase Cubical Ct 100/1, 100/1, 75/1, 50/1, 20/1, 200/1, 30/1 Amp (With 0.2 Accuracy) With Transportation And Loading/Unloading Charges Of Ct Upto Site Under Electricity Test Division,
|
| Description |
For The Work Of Providing And Installation Of 33 Kv/110 Volt Single Phase Cubical Ct 100/1, 100/1, 75/1, 50/1, 20/1, 200/1, 30/1 Amp (With 0.2 Accuracy) With Transportation And Loading/Unloading Charges Of Ct Upto Site Under Electricity Test Division,
|
| Organisation | Dakshinanchal Vidyut Vitran Nigam Ltd. | State Govt. and UT |
| Tender Id | 2024_DVVNL_952337_1 |
|
Reference Number |
EDC/F/T-24 (2024-25) |
| Tender Fee | 1180 |
| EMD | 2000 |
| Tender Value | - |
| Place | Firozabad |
| Link |
View Original Tender Notice
https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1669838 |
| Start Date | September 27, 2024 23:30 |
| End Date |
Expired
02/10/2024
Expired 743 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ct 400-200-100/1-1-1a, 33kv, w/trmnl cnctr,pt, 33kv/110v, type o/d, 150va
Ct 400-200-100/1-1-1a, 33kv, w/trmnl cnctr,pt, 33kv/110v, type o/d, 150va
Read moreHand held 20k hz digital multimeter, dc voltage range 1000 volt, dc voltage accuracy 0.5 percent, dc voltage resolution 1 milli volt, ac voltage range 750volt, ac voltage accuracy 1 percent, ac voltage resolution 100 milli volt.
Hand held 20k hz digital multimeter, dc voltage range 1000 volt, dc voltage accuracy 0.5 percent, dc voltage resolution 1 milli volt, ac voltage range 750volt, ac voltage accuracy 1 percent, ac voltage resolution 100 milli volt.
Read moreCutting, loading, unloading and stacking of scrap 100 tonnes at r.store, jhingurda project
Cutting, loading, unloading and stacking of scrap 100 tonnes at r.store, jhingurda project
Read moreCustom bid for services - electrical works for providing speed 100 loading/unloading facility at irimpanam installation
Custom bid for services - electrical works for providing speed 100 loading/unloading facility at irimpanam installation
Read more33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc
33kv trip latch assembly,33kv big cam assembly,auxiliary switch,33kv push button bracket,h.d numerical relay,ht control fuse,current transformer ct,spring charging motor for 33kv 1250a,potential transfomer pt,33kv holding catch assembly,auxiliary relay 110 to 125v,tripping solenoid coil 110v dc,master trip relay 110v dc
Read moreElr w cbct 100-200vac 50 750ma,plug socket assy,compound wear abrsn rstnc resin hrdnr,ht hrc fuses 3.3 11 kv 100 160 amps,basic unit 150 kvar 3.3kv app type,0.2 per series rector dry type magnetica,cubical carrier assembly,fxt lghtg well gls 110v 20w led scrw flp
Elr w cbct 100-200vac 50 750ma,plug socket assy,compound wear abrsn rstnc resin hrdnr,ht hrc fuses 3.3 11 kv 100 160 amps,basic unit 150 kvar 3.3kv app type,0.2 per series rector dry type magnetica,cubical carrier assembly,fxt lghtg well gls 110v 20w led scrw flp
Read moreHiring of 10 tractor trolleys for 12 days for lifting loading transportation and disposal of garbage from ngt site including supply transportation unloading and spreading of 100 trolley loads of good earth at designated locations within mc hansi
Hiring of 10 tractor trolleys for 12 days for lifting loading transportation and disposal of garbage from ngt site including supply transportation unloading and spreading of 100 trolley loads of good earth at designated locations within mc hansi
Read moreAmpere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025
Ampere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025
Read moreNon-reversible thermal strips, vertical mounting self adhesive type, range from 50 to 120 deg c in steps of min 8 levels 50, 60, 70, 80, 90, 100, 110, 120 deg c, should show dual temp scale deg c and fahrenheit, should be oil, water dust and steam resistance, with accuracy of 1 percent +/- 1 deg c, size 40 x15mm, a colour change from silver/ white to black indicates that the rating has been reached for easy dentification stickers should be in blue/orange/yellow color.
Non-reversible thermal strips, vertical mounting self adhesive type, range from 50 to 120 deg c in steps of min 8 levels 50, 60, 70, 80, 90, 100, 110, 120 deg c, should show dual temp scale deg c and fahrenheit, should be oil, water dust and steam resistance, with accuracy of 1 percent +/- 1 deg c, size 40 x15mm, a colour change from silver/ white to black indicates that the rating has been reached for easy dentification stickers should be in blue/orange/yellow color.
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay