Tender Details
Particulars | Details |
---|---|
Title |
Repairing Of 01 No. Float Cum Boost Charger (100 A , Input 220 V, Output 110 V Dc) With Connection To All H.T Panel Of 3.3 Kv,11 Kv For Dc Supply 110 V Cro Substation Of Churi Colliery N K Area
|
Description |
Repairing Of 01 No. Float Cum Boost Charger (100 A , Input 220 V, Output 110 V Dc) With Connection To All H.T Panel Of 3.3 Kv,11 Kv For Dc Supply 110 V Cro Substation Of Churi Colliery N K Area
|
Organisation | Central Coalfields Limited | Public Sector Undertakings |
Tender Id | 2024_CCL_317860_1 |
Reference Number |
PE/ENM/CH/24-25/01 |
Tender Fee | 0 |
EMD | 2800 |
Tender Value | |
Place | Churi Colliery |
Link | https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=329450 |
Start Date | September 20, 2024 20:30 |
End Date |
28/09/2024 ( Expired 204 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Providing,supplying,erecting, commissioning with satisfactory tests and trial of 110 volt dc,30 amps float cum boost battery charger for janai lis stage1 and 2 and repairing of 110 volt dc,30amps float cum booster battery charger for janai lis
Providing,supplying,erecting, commissioning with satisfactory tests and trial of 110 volt dc,30 amps float cum boost battery charger for janai lis stage1 and 2 and repairing of 110&#x0d volt dc,30amps float cum booster battery charger for janai lis
Read moreSupply, design, and installation of ac dc float cum boost charger 110 v ac to dc with heavy duty industrial battery and laying of ac dc supply line for different circuit breakers at the 11 kv by 3.3 kv main substation, under karo ocp, bnk area
Supply, design, and installation of ac dc float cum boost charger 110 v ac to dc with heavy duty industrial battery and laying of ac dc supply line for different circuit breakers at the 11 kv by 3.3 kv main substation, under karo ocp, bnk area
Read moreSupply and testing of float cum boost battery charger, thyristor based with all accessories, input-415 vac, 3-phase, 50 hz, output 110-150v dc, 200 amp, ip 42 protection, rs 485 connectivity, modbus communication protocol, digital metering with touch screen, suitable for all types of battery , provided with 04 nos, heavy duty wheel arrangement in the base for movement/shifting to desired location
For complete deion and other details, please refer to tender
Read moreX2-6130-72-0470644 float cum boost charger fcbc 230v ac oblique 24v dc input and 48v x 4v output,x2
Read more
Tender for providing, erection, testing and commissioning of float cum boost battery charger for 30 volt, 100ah battery bank and 11kv cts at 33/11kv substation prini under esd no.ii hpsebl manali
Tender for providing, erection, testing and commissioning of float cum boost battery charger for 30 volt, 100ah battery bank and 11kv cts at 33/11kv substation prini under esd no.ii hpsebl manali
Read moreX2-6130-72-0470644 float cum boost charger fcbc 230v ac oblique 24v dc input and 48v x 4v output,x2
Read more
Custom bid for services - health checkup cum servicing of 220 v dc100a float cum boost charger fcbc
Read more
110v dc float cum boost battery charger of capacit
1)110v dc float cum boost battery charger of capacity 150a for power house as per specification no. hpe-ts-rt-02, rev.00 qty: 4 st 2)110v dc float cum boost charger of capacity 50a for dam as per technical specs hpe-ts-rt-02, rev. 00 qty: 2 st 3)48v dc float cum boost charger of capacity 25a for bf valve house as per technical specifications hpe-ts-rt-02, rev.00 qty: 2 st 4)48v dc float cum boost charger of capacity 25a for camp as per technical specifications hpe-ts-rt-02, rev.00 qty: 2 st 5)battery fuse cabinet for power house batteries (vrla batteries, 700ah, no. of cells=55, ecv=1.75v) as per technical specifications hpe-ts-rt-02, rev.00 qty: 2 no 6)battery fuse cabinet for dam battery (vrla batteries, 100ah, no. of cells=55, ecv=1.75v) as per specification no. hpe-ts-rt-02, rev.00 qty: 1 no 7)battery fuse cabinet for bf valve house battery (vrla batteries, 50ah, no. of cells=24, ecv=1.75v) as per specification no. hpe-ts-rt-02, rev.00 qty: 1 no 8)battery fuse cabinet for camp battery (vrla batteries, 50ah, no. of cells=24, ecv=1.75v) as per specification no. hpe-ts-rt-02, rev.00 qty: 1 no 9)mandatory spares as per technical specifications hpe-ts-rt-02, rev.00 qty: 1 st 10)supervision of commissioning of all supplied chargers (in toto) as per technical specifications hpe-ts-rt-02, rev.00 qty: 1 lt
Read moreSupply design and installation of ac/dc float cum boost charger 110 volt ac/dc with heavy duty industrial battery and laying of ac/dc supply line for different circuit breakers at 11kv/3.3kv main sub- station under akkocp, bnk area.
Supply design and installation of ac/dc float cum boost charger 110 volt ac/dc with heavy duty industrial battery and laying of ac/dc supply line for different circuit breakers at 11kv/3.3kv main sub- station under akkocp, bnk area.
Read more(a) repairing of primary control of flp type 315 kva, 3.3kv/550v tsu, electrotechnika flp sl. no. 1053 installed at 40l/6md (b) repairing/ reconditioning of 04 no. vcb panel, 1250 a, make meditron 3.3kv installed at cro sub-stn in churi colliery.
(a) repairing of primary control of flp type 315 kva, 3.3kv/550v tsu, electrotechnika flp sl. no. 1053 installed at 40l/6md (b) repairing/ reconditioning of 04 no. vcb panel, 1250 a, make meditron 3.3kv installed at cro sub-stn in churi colliery.