Tender Details
This tender closed on 09 Sep 2025. 6 tenders like it are open now.
| Particulars | Details |
|---|---|
| Title |
Power Contactor For Net 1 & 2 Conforming To Is/Iec: 60947 4 1 With 2 No 2 Nc Aux. Contact Of Utilization Category Percent U2013 6 A, Rated Voltage 1000 V Ac, Main Pole 4, Control Voltage 415 V Ac Percent B1 15 Percent With Surge Suppressor Of Type/Make: Lc1 D1150046 N5 La4 Da2 Nladn22 Of Schneider Make Or Af190 B 40 22 Of Abb Make Or 3 Rt23461 Avo04 Aa03 Rh29111 Ha113 Rt9361 Beo00 Of Siemens Make Or Mcx 34 Of L&T Make As Per Rdso Spec No. Rdso/Pe/Spec/Ac/0184 2015 (Rev 1) And As Per Of Comm
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106810657 |
|
Reference Number |
45251628 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Hubli |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092025/106810657/viewNitPdf_5095060.pdf |
| Start Date | August 28, 2025 20:55 |
| End Date |
Expired
09/09/2025
Expired 424 days ago |
Bidding on tenders like this?
Partners, bid preparation, supplier quotes and GeM registration, from our team and partners.
Get alerts for tenders like this
This one has closed. Tell us what you supply and we'll send you new tenders like it.
Free tender checklists for your industry →Open tenders like this
-
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 09/11/2026
View tender -
Contactor k44 for 60 kva transformer, rated current: 95 amps, rated voltage: 690 v ac, main pole: 4, aux contact: 1no + 1nc control voltage: 230 v ac (168 v ac- 300 v ac means 230 v ac +/- 30 percent) with surge suppressor as per rdso spec no. rdso/pe/spec/ ac/0184-2015 (rev - 1) or latest and as per update of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 or latest, to abb model no. af 116b-40, schneider model no. lc1d1150046m5 + la4da2u, c&s model no. lc1fdp1154u5+la9f9
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 10/11/2026
View tender -
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 10/11/2026
View tender -
Working and non-working net-1&2 power contactors, 3 pole, 1000v ac operational voltage, 50hz, suitable for 100kva, 750v ac, on load switching under ac-6a category at temperature of 70 c & coil voltage 110v +25 percent -30 percent dc at temperature of 70 c with surge suppressor, aux. contacts 2 no + 2nc confirming to rdso spec rdso/pe/spec/tl/0195 - 2019 ( rev. 0 ). for lslrd coach. make : 1) abb ( af 190 b-30-22rt-12 ) , 2) siemens (3rt10566la 068 k + 3rt 1955af 318k )3) l&t ( mo 140 ) , 4
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 11/11/2026
View tender -
Kva ,750 v ac onload switching under ac-6a category at temperature of 70 degree centigrade & coil voltage of 110 v+ 25 percent -30 percent dc with surge suppressor ,2 no+2 nc for lslrd coaches as per rdso specification no .rdso/pe/spec/tl/0195-2019 (rev.-0)or latest. accepted makes as per above spec.: abb modelno.af1250-30-11, l&t model no. mvo 820, siemens model no3tf69338 df4z a02+3tx75723h only.
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 17/11/2026
View tender -
Air circuit breaker (acb) suitable for lhb power car of system voltage-750 v, capacity-800 amp, breaking capacity-50ka, frequency-50 hz, 3 pole mf (with inbuilt uv protection, thermal, magnetic release), 6 no + 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type: cn-cs 800c conforming to rcf specification no: edts 103, rev-d, am-07 or latest, make- lauritz knudsen formerly l&t/abb/ge only.
For complete description and other details, please refer to tender document.
Ministry of Railways Closes 09/11/2026
View tender -
Contactor(with diode), current rating: 32 a, voltage rating: 415 v, main pole: 3 no, aux. contact: 1nc, control voltage: 77-143 v dc with surge suppressor as per sn-55 of bom for rdso spec. no. rdso/pe/spec/ac/0184 percent u2013 2015 (rev. 1)
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Guwahati Closed 09/12/2024
View tender -
Auxiliary contactor, for controller ok contacts: 3 no 1 nc control voltage: 77- 143 v dc with surge suppressor
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · New Delhi Closed 16/05/2024
View tender -
85 amps power contactor, contact voltage: 415 v ac, pole: 3 pole, auxiliary contact: 2 no 2 nc, coil voltage: 110 v / 230 v / 415 v ac, conforming to is/iec: 60947-4-1.
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Chennai Closed 07/10/2025
View tender -
Contactor 4 pole, 200 amp suitable for 750 v ac, 50 hz., coil alongvwith voltage 110 v dc surge suppressor
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Chennai Closed 31/07/2024
View tender