Tender Details

About Tender

🚂 Procurement Opportunity: Auxiliary Contactor For Railway Signaling System 🔧 The Ministry Of Railways, Central Government, Invites Bids For The Supply Of Auxiliary Contactor With Specifications Including 3 No Ok Contacts, 1 Nc Contact, And Control Voltage Ranging From 77 143 V Dc With A Surge Suppressor. 📅 Bid Submission Deadline: May 16, 2024, 11:00 Am Emd: Inr 4160 Interested Bidders Are Advised To Review The Complete Tender Document For Detailed Requirements And Submission Guidelines. Keywords: Auxiliary Contactor, Railway Signaling System, Ministry Of Railways, Central Government, Tender, Electrical Equipment, Surge Suppressor, Procurement
Particulars Details
Title
Auxiliary Contactor, For Controller Ok Contacts: 3 No 1 Nc Control Voltage: 77 143 V Dc With Surge Suppressor
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106336647
Reference
Number
61245638
Tender Fee 0
EMD 4160
Tender Value -
Place New Delhi
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/052024/106336647/viewNitPdf_4560064.pdf

Start Date May 04, 2024 15:04
End Date
Expired 16/05/2024

Expired 884 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Read more
Starter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras

Starter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras

Read more
Auxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2

Auxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2

Read more
Contactor 170 amps 4 pole with auxillary contacts 1 no +1 nc coil voltage 415 v ac as per abb type ek -110-40-11+cal 16. 11b accepted brand abb /schneider / siemens only.

Contactor 170 amps 4 pole with auxillary contacts 1 no +1 nc coil voltage 415 v ac as per abb type ek -110-40-11+cal 16. 11b accepted brand abb /schneider / siemens only.

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Read more
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Read more
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Read more
Auxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.

Auxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.