Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Installation Of Ht, Lt , Poles With Wring Ward No. 3,4,7, And 8with 63 K Va Transformer At Ward 3. Block(singhpora), Ph(singh Pora) Under Pri Grants 2023 24
|
| Description |
Installation Of Ht, Lt , Poles With Wring Ward No. 3,4,7, And 8with 63 K Va Transformer At Ward 3. Block(singhpora), Ph(singh Pora) Under Pri Grants 2023 24
|
| Organisation | Government of Jammu and Kashmir |
| Tender Id | 2023_PDD_222923_1 |
|
Reference Number |
EMDS/135 |
| Tender Fee | 535 |
| EMD | 21340 |
| Tender Value | - |
| Place | EXECUTIVE ENGINEER ELECTRIC DIVISION SOPORE |
| Link |
View Original Tender Notice
https://jktenders.gov.in |
| Start Date | July 26, 2023 21:30 |
| End Date |
Expired
16/08/2023
Expired 1158 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ca no cweafj-38/2026-27 repair and maint of transformer, ht cable poles and its connected items at air force station pathankot under ge (af) pathankot
Ca no cweafj-38/2026-27 repair and maint of transformer, ht cable poles and its connected items at air force station pathankot under ge (af) pathankot
Read moreExtension of ht line including installation of 63 kva distribution transformer at svo3 station panisagar agartala pipeline of m/s indradhanush gas grid india at gangacharra mouza of longtarai valley under esd-ambassa.
Extension of ht line including installation of 63 kva distribution transformer at svo3 station panisagar agartala pipeline of m/s indradhanush gas grid india at gangacharra mouza of longtarai valley under esd-ambassa.
Read moreRate contract for supply, erection/creation, testing and commissioning of 25/63/100/250 kva transformer substation along with laying of ht and lt line on turnkey basis under the jurisdiction of executive engineer electric division vijaypur, jpdcl
Rate contract for supply, erection/creation, testing and commissioning of 25/63/100/250 kva transformer substation along with laying of ht and lt line on turnkey basis under the jurisdiction of executive engineer electric division vijaypur, jpdcl
Read moreTransformer 400 kva,oil type transformer160 kva,11 kv vce 3 way,11kv vce 2 way,11 kv load break switch,g o d o 11 kv switch with 2 cement poles,copper earthing chemical,gi earthing chemical,120 sqmm al cable,300sqm al cable,ht meter box,ht joint box indoor and outdoor,ct pt 20 by 5,ct pt 15 by 5,right angle boot,jdvvnl liasoning
Transformer 400 kva,oil type transformer160 kva,11 kv vce 3 way,11kv vce 2 way,11 kv load break switch,g o d o 11 kv switch with 2 cement poles,copper earthing chemical,gi earthing chemical,120 sqmm al cable,300sqm al cable,ht meter box,ht joint box indoor and outdoor,ct pt 20 by 5,ct pt 15 by 5,right angle boot,jdvvnl liasoning
Read moreCustomized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with 3 core ht cable as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 63 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 250 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - lt service connection with lt cable including liasoning with pdd authorities for arranging of shut down complete as required at site with periodic insp
Customized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with 3 core ht cable as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 63 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 250 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - lt service connection with lt cable including liasoning with pdd authorities for arranging of shut down complete as required at site with periodic insp
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreCustomized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 63 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 15 kva capacity automatic voltage regulators as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 30 kva capacity automatic voltage regulators as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 15 kva capacity feeder panel, lt panel, sdbs, change over switches and cables as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 30 kva capacity feeder panel, lt panel, sdbs, change o
Customized amc/cmc for pre-owned products - 25 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 63 kva rating transformer substation with external service connection with ht acsr conductor as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 15 kva capacity automatic voltage regulators as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 30 kva capacity automatic voltage regulators as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 15 kva capacity feeder panel, lt panel, sdbs, change over switches and cables as per atc comprehensive maintenance contract (cmc) as per atc no,customized amc/cmc for pre-owned products - 30 kva capacity feeder panel, lt panel, sdbs, change o
Read moreInstallation of lt poles along with wires at w 05 block(singhpora), ph(singh pora) under pri grants 2023-24
Installation of lt poles along with wires at w 05 block(singhpora), ph(singh pora) under pri grants 2023-24
Read moreCreation of 63 kv transformer mir mohalla omburn block(singhpora), ph(om burn) under pri grants 2023-24
Creation of 63 kv transformer mir mohalla omburn block(singhpora), ph(om burn) under pri grants 2023-24
Read moreof your Industry type