Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Complete Repairing And Overhauling Of 300 Kva, 3.3 Kv/550 V Transformer, E.C.E Make, Sl.No.Mld 02 For Water Supply Of Office Colony And Near Basti Under Murulidih 20/21 Pits Colliery
|
| Description |
Complete Repairing/Rewinding Of Transformer 300 Kva, 3.3 Kv/550 V At Old Mld 20/21 
Pits Colliery
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2024_BCCL_301900_1 |
|
Reference Number |
BCCL/WJA/AM(ENM)/23-24/RP-155 |
| Tender Fee | 0 |
| EMD | 1614 |
| Tender Value | - |
| Place | Murulidih 20/21 Pits Colliery |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=312745 |
| Start Date | February 19, 2024 18:30 |
| End Date |
Expired
28/02/2024
Expired 959 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing and rewinding of 1mva transformer 11kv 3.3kv of amritnagar colliery
Repairing and rewinding of 1mva transformer 11kv 3.3kv of amritnagar colliery
Read moreComplete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Complete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery
Read moreRewinding of 15kva, 550v/220v lighting transformer, of view point area of east basuria colliery
Rewinding of 15kva, 550v/220v lighting transformer, of view point area of east basuria colliery
Read more(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e
(i)for maintenance of one no.1 mva 6.6kv/550v transformer installed at loyabad colliery make-ece,asset sl.no.arn/14 lbc(ii)complete rewinding and overhauling of a 750 kva power transformer 6.6kv/550v at 5 pit substation of lbc make-ece asset.no.loy/e
Read moreFor dismantling of ocp substation shed of size 50 ft x 50 and dismantling shifting, loading unloading of 1.5mva,6.6kv/3.3kv, transformer of badeopur colliery under sijua area
For dismantling of ocp substation shed of size 50 ft x 50 and dismantling shifting, loading unloading of 1.5mva,6.6kv/3.3kv, transformer of badeopur colliery under sijua area
Read more1.drawing of 1 new 440 v overhead line (500 m) from no.2 pit substation to agent office, kumardhubi colliery, 2. new 550v overhead line (300 m) from no. 2 pit substation to no. 2 pit fan house at kumardhubi colliery, mugma area, ecl.3.a) drawing of n
1.drawing of 1 new 440 v overhead line (500 m) from no.2 pit substation to agent office, kumardhubi colliery, 2. new 550v overhead line (300 m) from no. 2 pit substation to no. 2 pit fan house at kumardhubi colliery, mugma area, ecl.3.a) drawing of n
Read moreHand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Hand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreComplete rewinding and repairing of a 500kva 3.3kv/550v burnt power transformer at murulidih filter house of murulidih 20/21 pits colliery. sl.no.224197/4
Complete rewinding and 
 repairing of a 500kva 
 3.3kv/550v burnt power 
 transformer at murulidih 
 filter house of murulidih 
 20/21 pits colliery. 
 sl.no.224197/4
Read moreComplete rewinding and repairing of a 500kva 3.3kv/550v burnt power transformer at murulidih filter house of murulidih 20/21 pits colliery. sl.no.224197/4
Complete rewinding and 
 repairing of a 500kva 
 3.3kv/550v burnt power 
 transformer at murulidih 
 filter house of murulidih 
 20/21 pits colliery. 
 sl.no.224197/4
Read moreof your Industry type