Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Procurement Of Sealant For Transformers Oil Leakage Arresting Andcoating For Busbar Insulation Protection And Gt Below Repair And Brokenporcleain Or Insulator Repair Items Of Itw Make For Ntpc Dadri
|
| Description |
Procurement Of Sealant For Transformers Oil Leakage Arresting Andcoating For Busbar Insulation Protection And Gt Below Repair And Brokenporcleain Or Insulator Repair Items Of Itw Make For Ntpc Dadri
|
| Organisation | NTPC Limited | Public Sector Undertakings |
| Tender Id | 2024_NTPC_83667_1 |
|
Reference Number |
NTPC/USSC-CPG3/9900273592 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Simhadri Super Thermal Power P.O. SIMHADRI VISAKHA |
| Link |
View Original Tender Notice
https://eprocurentpc.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=86851 |
| Start Date | January 31, 2024 00:25 |
| End Date |
Expired
08/02/2024
Expired 983 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33
3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33
Read moreArresting leakage or seepage of gt 1,gt 2 hall and roofs of others buildings at pps i
Arresting leakage or seepage of gt 1 gt 2 hall and roofs of others buildings at pps i
Read moreFilteration of oil and arresting leakage of oil in transformers in the factory
Filteration of oil and arresting leakage of oil in transformers in the factory
Read moreSocket insulator,copper busbar,transformer,earth leakage relay,f switch,15v signaling bell,brush ca
Read more
Repair, leakage arresting, service and re- painting to the 13 nos of transformers....itemrates.
Repair, leakage arresting, service and re- painting to the 13 nos of transformers....itemrates.
Read moreFiltration of oil of transformers and arresting of oil leakage of different type transformer
For complete deion and other details, please refer to tender
Read moreArresting of oil leakage in power transformers and instrument transformers at various substations under 220kv oandm division, ptcul, haldwani
Arresting of oil leakage in power transformers and instrument transformers at various substations under 220kv oandm division, ptcul, haldwani
Read morePainting work of power transformers and arresting oil leakage from various points of power transformers at 132 kv substation, roorkee
Painting work of power transformers and arresting oil leakage from various points of power transformers at 132 kv substation, roorkee
Read moreArresting of leakage and other general maintenance work of power transformers at various substations store kesco
Arresting of leakage and other general maintenance work of power transformers at various substations store kesco
Read moreArresting of oil leakage in power transformers and instrument transformers at 220kv s/s, haldwani under 220kv oandm division, ptcul, haldwani
Arresting of oil leakage in power transformers and instrument transformers at 220kv s/s, haldwani under 220kv oandm division, ptcul, haldwani
Read moreof your Industry type