Tender Details
Particulars | Details |
---|---|
Title |
Mpcb For Ventilation Fan Unit 1 & 2, Thermal Release Range (Rated Current) : 2.5 4.0 A, Class 10, Breaking Capacity : 50 Ka, 3 Pole, Rated Voltage 415 V Ac, 1 No 1 Nc Auxiliary Contact Block As Per Rdso Common Bill Of Material Letter No El/7.108/Mssbc Dated 17.09.21, Make Abb Catalogue No Ms 116 4 / Legrand / Eaton / Schneider Catalogue No Gv2 Me08 Gvae11/ L&T Catalogue No St418960000/ Siemens Catalogue No 3 Rv2011 1 Ea103 Rv2901 1 E Only.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106473765 |
Reference Number |
19247001 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Allahabad |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/102024/106473765/viewNitPdf_4715295.pdf |
Start Date | September 13, 2024 23:12 |
End Date |
14/10/2024 ( Expired 189 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Dc to dc converter for switch board cabinet of lhb ac coaches-110/24 v,240w, 10a as per abb catalogue no: cp-c.1 24/10, phoenix catalogue no: trio-ps-2g/1ac/24dc/10-2903149, cosel catalogue no: klea240f-24, siemens catalogue no: 6ep13363ba10 and ask powertech catalogue no. ask-cs-24v, 10a as per rdso spec. no. rdso/pe/spec/ac/0184 2015 rev.1 & rdso lr.no. el/7.1.108/mssbc, dt 17/09/21.
For complete deion and other details, please refer to tender
Read moreDc to dc converter for switch board cabinet of lhb ac coaches - 110/24 v, 1.5 a as per abb model no: cp-e 24/2.5, cosel powertech model no. lga50a-24sn(2.1a), phoenix model no. step-ps/1a/24dc/1.75, schneider model no.abl8rem24030, siemens model no. 6ep33216sb100ay0 as per the bill of material of rdso spec. no: rdso/pe/spec/ ac/ 0184 - 2015 (rev-1) and rdso lr.no. el/7.1.108/mssbc, dt 17/09/21.
For complete deion and other details, please refer to tender
Read moreMotor protection circuit breaket (mpcb) of rated current 1-1.6 amp with 2 nos aux contacts (1no1nc aux contact block), thermal range 1-1.6 amp, class-10, breaking capacity-50ka, 3pole, rated voltage 690vac, confirming to rdso modification sheet no. rdso/pe/ms/tl/0090-2023 (rev-0). rdso approved make & cat no.:- abb cat no. ms116-1.6, hk1-11, schneider cat no. gv2-me06gv-ae11, siemens cat no. 3rv20111aa103rv2901-1e, and l&t cat no. st418940000st419450000.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) 2.5 - 4 a, class 10, breaking capacity 50ka, pole 3p, rated voltage 415v ac, 1 no 1 nc auxilary contact block confirming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0).
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read more3-pole mcb, rated current: 16a, curve: d , voltage 415v ac, breaking capacity: 10 ka of make: l&t of model no. bb30160d or siemens of model no. 5sl73168rc or abb of model no. sb203 m-d16 or schneider of model no. a9n3p16d or legrand of model no. 408762. conforming bom of rdso specification no. rdso/pe/spec/ac/0192-2018 (rev.1)
For complete deion and other details, please refer to tender
Read moreMcb 06 amps,3 pole as per intec part no. icac-075 for roof mounted air conditioning system of cab ac as per rdso specification no. rdso/2007/el/spec/0055 rev. 2. make : l&t/abb/siemens/schneider/legrand. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram/fedders lylord/sidwal/kki fitted in electric loco.
For complete deion and other details, please refer to tender
Read moreMain mcb 16 amps, 3pole to intec part no.icac-074 for roof mounted air conditioning system of cab ac as per rdso specification no. rdso/2007/el/spec/0055 rev. 2. make : l&t/abb/siemens/schneider/legrand. note: 1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram/fedders lylord/sidwal/kki fitted in electric loco.
For complete deion and other details, please refer to tender
Read moreMpcb 1.0 to 1.6 amp to intec part no. icac-101 for roof mounted air conditioning system of cab ac as per rdso specification no. rdso/2007/el/spec/0055 rev. 2. make l & t/abb/siemens/schneider/legrand. note:- (1) item should be suitable for 2t capacity roof mounted cab ac of make daulatram/fedders lylord/sidwal/kki fitted in electric loco.
For complete deion and other details, please refer to tender
Read moreContactor k-44 for 60 kva transformer rated current -95 amp, rated voltage690 v ac, main pole - 4, auxillary contact 1 no 1 nc, control voltage - 230 volt ac (168 v ac300 v ac) with surge suppressor. place of location in sbc : s1k44conf make : abb, schneider, siemens & l&t only
For complete deion and other details, please refer to tender
Read moreof your Industry type