Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Consultancy Charge For Testing And Calibration Of Breaker Transformer Earth Pit Overhead Line (11 Kv And 3.3 Kv) And Cable Installed At New Sub Station Of Kujama Colliery
|
| Description |
Consultancy Charge For Testing And Calibration Of Breaker Transformer Earth Pit Overhead Line (11 Kv And 3.3 Kv) And Cable Installed At New Sub Station Of Kujama Colliery
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2024_BCCL_323519_1 |
|
Reference Number |
BCCL/LA/EnM/F-19/24-25/144 |
| Tender Fee | 0 |
| EMD | 6611 |
| Tender Value | - |
| Place | Lodna Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=335358 |
| Start Date | December 18, 2024 15:30 |
| End Date |
Expired
30/12/2024
Expired 655 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Maintenance and diversion of 440 v/3.3 kv o.h. lines electrification works at various locations of kuju colliery under kuju area.
Maintenance and diversion of 440 v/3.3 kv o.h. lines electrification works at various locations of kuju colliery under kuju area.
Read moreAnnual maintenance of different 11 kv ht incoming and differernt 3.3 kv ht outgoing overhead power lines of jocp for a period of 12 months alongwith the renovation of lightning protection system of main substation, laiyo substation and mines at
Annual maintenance of different 11 kv ht incoming and differernt 3.3 kv ht outgoing overhead power lines of jocp for a period of 12 months along with the renovation of lightning protection system of main substation, laiyo substation and mines at
Read moreDay-to-day work of dismantling, erection, and maintenance of 11 kv, 3.3 kv, and lt overhead lines, including dismantling and erection of light fittings mounted on poles, structures, and high mast towers, etc., at the surface area of ananta ocp, ja.
Day-to-day work of dismantling, erection, and maintenance of 11 kv, 3.3 kv, and lt overhead lines, including dismantling and erection of light fittings mounted on poles, structures, and high mast towers, etc., at the surface area of ananta ocp, ja.
Read moreCircuit breaker, mccb, 400a, 415 v, 4 p, w suitbl,track nut,track bolt,dowel pin,thermal overload relay,power contactor, 415 - 550, 3 p, 300a,earth leakage relay,hex head bolt,fixt light, 230v, 100 w, led flood,fixt light, 230v, 30 w, led screw,cable, 1.1 kv, 2c, cooper, pvc, 1.5 mm2,cable, 3.3 kv, 3 c, copper, pvc, 95 mm2 mining
Circuit breaker, mccb, 400a, 415 v, 4 p, w suitbl,track nut,track bolt,dowel pin,thermal overload relay,power contactor, 415 - 550, 3 p, 300a,earth leakage relay,hex head bolt,fixt light, 230v, 100 w, led flood,fixt light, 230v, 30 w, led screw,cable, 1.1 kv, 2c, cooper, pvc, 1.5 mm2,cable, 3.3 kv, 3 c, copper, pvc, 95 mm2 mining
Read moreEarth electrode primary electrode,mccb,residual current cuircuit breaker rccb,earth leakage circuit breaker elcb,solar insulation meter,digital lux meter,magnetic flux meter,tong tester,sun shine recorder,battery storage lead acid,battery charger,solar charge controller with dusk to dawn automatic switching,solar charge controller with manual switch day lighting,array junction box for connecting 250w x 4 nos,solar lantern led type,clinometer for angle measurement,phase sequence indicator,pwm controller,mppt charge controller,inverter,solar street light,rechargeable battery,rheostat sliding type,rheostat sliding type,bus bar with brackets 1 mtr each,milli voltmeter centre zero analog portable box type housed in bakelite case 100 to 0 to 100 mv,tachometer digital photo sensor type,single phase variable auto transformer 0 to 270 v 10amp air cooled,phase sequence indicator 3 phase, 415 v,growler,ac starters,ac starters,ac starters,function generator 2 to 200 khz sine square triangular 220 v 50 hz single phase,imm
Earth electrode primary electrode,mccb,residual current cuircuit breaker rccb,earth leakage circuit breaker elcb,solar insulation meter,digital lux meter,magnetic flux meter,tong tester,sun shine recorder,battery storage lead acid,battery charger,solar charge controller with dusk to dawn automatic switching,solar charge controller with manual switch day lighting,array junction box for connecting 250w x 4 nos,solar lantern led type,clinometer for angle measurement,phase sequence indicator,pwm controller,mppt charge controller,inverter,solar street light,rechargeable battery,rheostat sliding type,rheostat sliding type,bus bar with brackets 1 mtr each,milli voltmeter centre zero analog portable box type housed in bakelite case 100 to 0 to 100 mv,tachometer digital photo sensor type,single phase variable auto transformer 0 to 270 v 10amp air cooled,phase sequence indicator 3 phase, 415 v,growler,ac starters,ac starters,ac starters,function generator 2 to 200 khz sine square triangular 220 v 50 hz single phase,imm
Read moreFuse cartage, ht 2a, 3.3 kv,coil, 110v, oprt,flood light, led, 100w, ip65, w 10 nos, 10,plug insulator with tube set,thermal overload relay,earth leakage relay, 110v rating elm 8,potential transformer,isolator reversing 300a,contactor, main, 550v, 300a,relay digital, led,24-260vac, 24-360 v dc, 1a-5a,hrc fuse,moving contract assembly,spndl, ss, w-brs nut, f-ft valve - size8 in,cable 1.1 kv, 2c, copper, pvc, 1.5mm2, flexible
Fuse cartage, ht 2a, 3.3 kv,coil, 110v, oprt,flood light, led, 100w, ip65, w 10 nos, 10,plug insulator with tube set,thermal overload relay,earth leakage relay, 110v rating elm 8,potential transformer,isolator reversing 300a,contactor, main, 550v, 300a,relay digital, led,24-260vac, 24-360 v dc, 1a-5a,hrc fuse,moving contract assembly,spndl, ss, w-brs nut, f-ft valve - size8 in,cable 1.1 kv, 2c, copper, pvc, 1.5mm2, flexible
Read morePole, pcc, 9 m,fixt lighting, 230 v, 150 w, led, screw,cable, 1.1 kv, 2c, copper, pvc, 1.5 mm2, flexible,overload relay, thrml, 100-150 a,ictp switch, 415-550v, 32 a, 3 p,cable joint kit, 35mm2, copper, 3.3 v, 3 c,earth leakage relay, 50-750 ma with time lag with cbct,moving contact,fixed contact,potential transformer 550-220v, 50va
Pole, pcc, 9 m,fixt lighting, 230 v, 150 w, led, screw,cable, 1.1 kv, 2c, copper, pvc, 1.5 mm2, flexible,overload relay, thrml, 100-150 a,ictp switch, 415-550v, 32 a, 3 p,cable joint kit, 35mm2, copper, 3.3 v, 3 c,earth leakage relay, 50-750 ma with time lag with cbct,moving contact,fixed contact,potential transformer 550-220v, 50va
Read moreAmpere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025
Ampere meter 4inch ratio 200 100 5 5a part no spl406,volt meter 3.3kv 100v part no spl106,ammeter selector switch part no srp136ma,voltmeter selector switch part no srp135vs,earth leakage relay 0.34 to 1.8a aux supply 110v cbct part no ekjrc172,wiring kit part no ek805888,epoxy resin cast ct double core 15va ratio 200 100 5 5a part no ct5300,epoxy resin cast potential transformer 3.3 kv 110v 3phase part no et08002,power pack unit 110v dc part no ek801025
Read moreNeon tester,three phase energy meter analog,watt meter dynamo meter type,meter reading instrument or mri,conduit pipe cutting and threading machines adjustable for 15 mm to 30 mm,crimping tool for crimping 16 sq mm to 95 sq.mm,crimping tool plier 9 inch hex series,wire cutter and stripper,wiring board on stand,screw driver,foot print grip,scissors electrician,scissors blade electrician,contactor with auxiliary contacts,limit switch,cut out relays,over load relays,under voltage relays,insulator pin type including hardware fitting,insulator shackle types including hardware fitting,insulator egg type including hardware fitting,insulator suspension type including hardware fitting,earth copper plate,earth electrode primary electrode,earth electrode secondary cu strip,residual current cuircuit breaker or rccb 25 amp,rechargeable battery,solar panels,solar charge controller with manual switch for day lighting,motion detector,electric kettle,electric heater,table fan a.c.,manual motor coil winding machine with step a
Neon tester,three phase energy meter analog,watt meter dynamo meter type,meter reading instrument or mri,conduit pipe cutting and threading machines adjustable for 15 mm to 30 mm,crimping tool for crimping 16 sq mm to 95 sq.mm,crimping tool plier 9 inch hex series,wire cutter and stripper,wiring board on stand,screw driver,foot print grip,scissors electrician,scissors blade electrician,contactor with auxiliary contacts,limit switch,cut out relays,over load relays,under voltage relays,insulator pin type including hardware fitting,insulator shackle types including hardware fitting,insulator egg type including hardware fitting,insulator suspension type including hardware fitting,earth copper plate,earth electrode primary electrode,earth electrode secondary cu strip,residual current cuircuit breaker or rccb 25 amp,rechargeable battery,solar panels,solar charge controller with manual switch for day lighting,motion detector,electric kettle,electric heater,table fan a.c.,manual motor coil winding machine with step a
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreof your Industry type