Tender Details
Particulars | Details |
---|---|
Title |
Cam Operated Rotary Switch Change Over With Centre Off (90 Degree) 1 0 11 O, 3 Pole 2 Way, 16
Amps, As Per Following Details: I) Current Rating: 16 Amps Ii) Operating Voltage: 690 Volts Ac, Iii) Contact Type: Normally
Closed Iv) Terminal: Screw Type V) Mounting Code: B03 Front Mounting, Standard Mounting Plate Similar To L & T
(Salzer) Make Cat. No. 61153 (16 A S16 61153 B03 Tdyr). Make As Per Bom Of Rcf Spec Edts 355, Rev.1 Amdt.
6 I.E. Siemens/L&T (Salzer)/Teknic/Ge/Kaycee.
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106399137 |
Reference Number |
L3245492 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Hubli |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/072024/106399137/viewNitPdf_4631446.pdf |
Start Date | July 05, 2024 17:01 |
End Date |
11/07/2024 ( Expired 284 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Power contactor 70 amps, 415 v, triple pole, with 2 no2nc aux contacts (side mounting), coil voltage 415v ac, confirming to is/iec 60947, part 4/sec 1. as per rcf specification no. edts-041, rev.-b. suitable for use in 200a battery charging unit of sg ac coaches. accepted make : siemens. abb, l&t. schneider only.
For complete deion and other details, please refer to tender
Read more4-pole contactors for controlling power circuits (k0l & k02) up to 690 v ac and 440v dc. a50-40-00 380-400v 50hz/400-415v 60hz abb: product id: lsbl35l20lr8400 along with ca5-22e auxiliary contact block abb product id: lsbn0l0040rl022 and rv5/133 surge suppressor abb: sbn0500l0rl 001. required make: abb, siemens, l&t or schneider as per edts.355.
For complete deion and other details, please refer to tender
Read moreRotary switch for feeder changeover of c [rotary switch for feeder changeover of capacity 16 amp, 02 pole, 02 way with center off as per part no. 16 as 16-61026-b03 tdyr of salzer (l&t) confirming to iec60947-3, ac21a, 690v-16a or equivalent make of siemens or kaycee confirmation to rcf specification no. edts-355 (rev-1) am 4 sr. no. 49. material make is l&t/salzer/siemens or kaycee only. material shall be procured from oem or his authorized dealers with tender specific authorization only.]
For complete deion and other details, please refer to tender
Read more4-pole contactors for controlling power circuits (k0l & k02) up to 690 v ac and 440v dc. a50-40-00 380-400v 50hz/400-415v 60hz abb: product id: lsbl35l20lr8400 along with ca5-22e auxiliary contact block abb product id: lsbn0l0040rl022 and rv5/133 surge suppressor abb: sbn0500l0rl 001. required make: abb, siemens, l&t or schneider as per edts.355.
For complete deion and other details, please refer to tender
Read more[set of rotary switches consisting of (i) rotary switch for feeder changeover of capacity 16a, 02 pole,02 way with centre off as per part no.16a s16-61026-bo3-tdyr of salzer (l&t) as per rdso specification no.edts355 (rev-1) or latest -1 no. (ii) cam operated rotary switch with 90 degree operation complete rotation 6 amps, with 2 pole on/off cam operated switch similar to salzer part no.6a-s6- 61198-b13-tdyr as per annexure a, page no. 20 of 46, sl. no. 49 of rdso specification no. edts-355 (r
For complete deion and other details, please refer to tender
Read moreBattery cutoff switch - 4 inline termina [battery cutoff switch - 4 inline terminals - 24v/2500amp, current rating 2500 amps, operating voltage 24 volts, contact type normally open, item dimensions (l x w x h) 11 x 13.5 x 14 centimeters, make- sinco/ uno/minda/suraj only.]
For complete deion and other details, please refer to tender
Read moreFuse base suitable for din type hrc fuse link with blade contacts having 160 amps rating, size 00, 415v ac, breaking capacity of 80 ka at 415v ac, similar to l&t make cat no. hb 160 (sk 90405) or siemens 3nh3032 -orc.
For complete deion and other details, please refer to tender
Read moreAuto manual bye pass,rotary switch for air conditioning current rating- 16a, position-3 (auto, manual, off) ,no. of poles-7 as per s.no. 192 of bill of material of rdso spec. no.rdso/pe/spec/ac/0184-2015(rev-0) and confirming to rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-0) . suitable for use in switch board cabinet of lhb type ac coaches. make: l&t/salzer/kaycee/siemens
For complete deion and other details, please refer to tender
Read moreHrc fuse din type 40 amp, size-000, 690 volt, capacity 80/120ka, confirming to iec60269-2, is:13703 pt.2/sec.2 and as per cat. no.03915 of rating 40 a of m/s wohner or cat. no. nh00gg69v40 of m/s ferraz or cat. no. 3nv0-00-40a-gg-690v of m/s koncar or cat. no. 40nhg00b-690 of eaton or equivalent of m/s siemens/l&t/ge/tc make for use in battery fuse box ve/-ve of lhb ac coaches as per rcf drawing nos. lw71001/2 (alt.-g) or latest.
For complete deion and other details, please refer to tender
Read moreSupply of hrc fuse, din type 16 amp., 500 volt ac, breaking capacity 120 ka, confirming to iec 60269-2/is:13703 part2/sec.1 size nh000, gg/gl as per cat no. 03909 of m/s wohner in specification edts-355 rev-1, as per bom, acceptable makes: siemens, wohner, ital weber, ferraz, bussmann, schneider, ge, l&t only.
For complete deion and other details, please refer to tender
Read moreof your Industry type